Continued

Day and Time Display

• 

The current day of week and time of day will be continuously dis-

played in the TIME/PROG Zone (except during Setup operations).

• 

The day of week will be displayed as one of the following: S, M, 

T, W, T, F, S

• 

The time of day will be in 12-hour AM, 12-hour PM format.  

Midnight will be displayed as 12:00am.

• 

Day/Time Setup:

• 

Press and hold the MODE Zone or the MODE/SET Button 

for 5 seconds to enter Day/Time Setup.

• 

Press the UP or DOWN Buttons to adjust the day of week 

(press the MODE/SET Button or wait for 15 seconds for ad-

justment to be accepted, then enter hour of day adjustment).

• 

Press the UP or DOWN Buttons to adjust the hour of the 

day.  The time will advance in 1-hour increments; AM and 

PM will change when the hour advances to 12:00 midnight 

and 12:00 noon respectively (press the MODE/SET Button 

or wait for 15 seconds for adjustment to be accepted, then 

enter minute of hour adjustment).

• 

Press the UP or DOWN Buttons to adjust the minute of the 

hour. The time will advance in 1-minute increments (press 

the MODE/SET Button or wait for 15 seconds and the 

transmitter will exit Day/Time Setup and return to normal 

operation).

• 

LCD Displays – when in Day/Time Setup:

 MODE Zone: Blank
 ROOM TEMP Zone: Blank
 SET TEMP Zone: Blank
 LIGHT Zone: Blank
 FAN Zone: Blank
 TIME/PROG Zone: Day of Week, or Time of Day will Flash
 AUX Zone: Blank
 FLAME Zone: Blank

• 

Temperatures may be displayed in degrees F (factory default) 

or degrees C. Press the up and down buttons simultaneously 

to change between degrees F. and C.

MODES OF OPERATION
Operation modes:

• 

MANUAL OFF

• 

MANUAL ON

The modes may be cycled in the order above by pressing the MODE 

Zone or the MODE/SET Button.

MANUAL OFF MODE

• 

Transmits flame OFF command.

• 

LCD Displays:

• 

MODE Zone: OFF is displaye

• 

ROOM TEMP Zone: Measured temperature is displayed

• 

SET TEMP Zone: Blank

• 

LIGHT Zone: LIGHT and light setting level is displayed

• 

FAN Zone: Blank

• 

TIME/PROG Zone: Current day indicator and current time 

is displayed

• 

AUX Zone: Blank (AUX function is omitted on this control)

• 

FLAME Zone: Blank

MANUAL ON MODE:

• 

Transmits flame ON command

• 

LCD Displays:

• 

MODE Zone: ON is displayed

• 

ROOM TEMP Zone: Measured temperature is displayed

• 

SET TEMP Zone: Blank

• 

LIGHT Zone: LIGHT and light setting level is displayed

• 

FAN Zone: FAN and fan setting level is unused

• 

TIME/PROG Zone: Current day indicator and current time 

is displayed

• 

AUX Zone: Blank (AUX function is omitted on this control)

• 

FLAME Zone: A&B Flame Icons and flame setting level 

numbers are displayed

FLAME - A (OR MAIN) ADJUSTMENT

• 

Transmits a flame height setting command to the control module 

to adjust the Flame-A height.

• 

Available settings are 1-7 with a factory default of 7. If the Flame-

A setting is changed during operation (either manually or auto-

matically), the control will remember and use the adjusted setting 

on subsequent manual ON cycles (Flame-A setting memory).

• 

While in MANUAL ON, or PROGRAM ON modes, press the FLAME 

Zone to enter Flame-A Adjustment, then press the UP or DOWN 

buttons to raise and lower the flame; press the MODE/SET Button 

or wait for 15 seconds to accept the new setting.

• 

LCD Display: When setting the Flame-A height, the Flame-A 

icon, and Flame-A setting number will flash in the FLAME Zone.

Figure 52 - Touch Screen Settings

Cont.

S M T W T F S

AM

PM

ROOM

SET

P1

A

B

P2

P2

AUX

P2

Pilot

:

OFF

ON

°

°

u

PROGRAM

USB

MODE/SET 

MODE Zone

LIGHT Zone

ROOM TEMP Zone

TIME/PROG. Zone

SET TEMP Zone (Unused)

AUX Zone (Unused)

FAN Zone (Unused)

DOWN 

Button

MODE/SET 

Button

UP Button

FLAME Zone

Содержание DRL4543TEN

Страница 1: ...icinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immedia...

Страница 2: ...MADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitr...

Страница 3: ...famille soient conscients du danger de br lure encouru Les surfaces de votre foyer deviennent EXTR MEMENT CHAUDES La vitre situ e l avant du foyer atteint des temp ratures EXTR MEMENT LEV ES et peut...

Страница 4: ...s viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une bar...

Страница 5: ...young children and other at risk individuals out of the room and away from hot surfaces This vented gas fireplace is a sealed combustion gas fireplace de signed for residential applications This firep...

Страница 6: ...uard or barrier removed for servicing an appliance must be replaced prior to operating the appliance SAFETY Continued Installation and repair should be done by a qualified service person The appliance...

Страница 7: ...NFPA 54 USA or the current CSA B149 1 Installation Code Canada Available from American National Standards Institute Inc 25 West 43rd Street 4th floor New York NY 10036 National Fire Protection Associa...

Страница 8: ...MONWEALTH OF MASSACHUSETTS Massachusetts Horizontal Vent Requirements In the Commonwealth of Massachusetts horizontal terminations installed less than seven 7 feet above the finished grade must comply...

Страница 9: ...t Do not locate termination cap and outside air vent where excessive snow or ice build up may occur Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting sy...

Страница 10: ...tible Material May Be Used TOP VIEW SAFE ZONE Perpendicular Wall 33 4 to Face Opening 5 53 1 4 1353 mm 53 1 4 1353 mm 38 965 mm 38 965 mm STUDS MOUNTED FLAT INSIDE OF NAILING FLANGE 15 1 4 387 mm MOUN...

Страница 11: ...m 16 1 2 419 mm 8 1 4 210 mm 29 7 8 759 mm 29 7 8 759 mm 3 1 2 89 mm 16 3 8 416 mm 7 1 8 181 mm 1 7 8 48 mm 8 1 4 210 mm 4 1 8 105 mm 44 1 8 1121 mm 55 1 8 1400 mm 47 1194 mm 1 25 mm 1 25 mm 52 1321 m...

Страница 12: ...en 10 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In C...

Страница 13: ...estops when penetrating ceilings or attic spaces For installation of fireplace at elevations of 4000 feet or greater pay special attention to venting requirement recommendations WARNING Read all instr...

Страница 14: ...rate a ceiling use plumb line to locate the center above the fireplace Cut and or frame an opening 10 1 2 x 10 1 2 267 x 267 mm inside dimensions about this center Figure 17 page 19 4 Attach the vent...

Страница 15: ...he firestop spacer may also be installed over the opening at the interior side of the framing 13 Install the termination SV4 5HTKCT From outside the exterior wall slide the collars of the termination...

Страница 16: ...silicone caulking to seal the top and sides of the termination up to the underlayment stucco or masonry wall surface Caulk Caulk NOTE See table 1 for wall thickness ranges when using SV4 5HTKCT termin...

Страница 17: ...seal both the inner and outer vent pipe 3 If desired a 6 x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 12 Figure 11 Connecting vent compon...

Страница 18: ...op spacer SF4 5VF When using Secure Flex use wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV4 5VF H V H1 V1 VENTING INSTALLATION Continued V Vertical Minimum Requi...

Страница 19: ...Frame the ceiling opening Use a plumb line from the ceil ing above the fireplace to locate the center of the vertical run Cut and or frame an opening 10 1 2 x 10 1 2 267 x 267 mm inside dimensions abo...

Страница 20: ...oof flashing over the vent sec tion and position such that the vent column rises vertically use carpenters level Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges...

Страница 21: ...west discharge opening H H minimum height from roof to lowest discharge opening of vent Horizontal overhang Vertical wall Vent termination Storm collar Concentric vent pipe Flashing 1 26 mm minimum cl...

Страница 22: ...OR VENTING KITS AND COMPONENTS Table 3 Listed Components Listed Secure Flex Components Continued F1801 SFKIT36CT Compact Termination for flex with 36 914 mm compressed flex F1802 SFKIT48CT Compact Ter...

Страница 23: ...vent 4 Slide the inner flex vent over the adaptor collar at least 1 3 4 5 NOTE Ensure the flex vent is free from damage or tears 6 Slide the gear clamp down and tighten it fully to secure the flexible...

Страница 24: ...ified service person must con nect fireplace to gas supply Follow all local codes CAUTION For propane LP units never connect fireplace directly to the propane LP supply This heater requires an externa...

Страница 25: ...ply line as shown in Figure 28 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and fireplace Locate sediment trap drip leg where trappe...

Страница 26: ...eplace or using compressed air 3 Check all joints from propane LP supply tank or gas meter to equipment shutoff valve see Figure 31 or Figure 32 Apply noncorrosive leak detection fluid to all joints B...

Страница 27: ...x using your fingers or the latch opener provided 3 Hook opener over latch as shown in Figure 34 Swing the bot tom of the opener down toward the door You will not need to pull down 4 Tilt open glass d...

Страница 28: ...embers to refresh the ember bed during annual maintenance Reinstall the included barrier J7457 WARNING Reinstall any barrier removed before operating the fireplace The barrier is designed to reduce th...

Страница 29: ...g Replacing Glass Door page 27 of this manual Installing Access Door Retaining Brackets 1 Screw access door retaining brackets into the inner side face using 2 screws on both the left and right side a...

Страница 30: ...use only non combustible materials You may extend up to the edge of the exterior door covering up the screws used for installation Installing Outdoor Barrier F2253 1 Using a flat head screwdriver pop...

Страница 31: ...nterrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette...

Страница 32: ...nge flamewillalsobepresent Openwindowtoventsmell This will only last a few hours 1 STOP Read the safety information in column 1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch...

Страница 33: ...a Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura...

Страница 34: ...e entire flame may be blue and will gradually turn yellow orange during the first 15 minutes of operation If the flame remains blue or if the flame is orange with evidence of sooting black tip the air...

Страница 35: ...rom glass If glass has been broken carefully remove glass door see Remov ing Replacing Glass Door page 27 Vacuum all glass pieces with a shop vacuum CAUTION Do not vacuum if pieces are hot Use only gl...

Страница 36: ...rammed to the Remote Control transmitter To program the module make sure the system has power locate the learn button on left side as shown in Figure 50 Press and release the learn button There will b...

Страница 37: ...order above by pressing the MODE Zone or the MODE SET Button MANUAL OFF MODE Transmits flame OFF command LCD Displays MODE Zone OFF is displaye ROOM TEMP Zone Measured temperature is displayed SET TEM...

Страница 38: ...OCK icon will appear in the MODE Zone If any touch zone or button is pressed when activated the LCD backlight will illuminate and the LOCK icon will flash for 5 seconds in the MODE Zone SENSOR SAFETY...

Страница 39: ...tor 110V MAX 15 AMPS 110V MAX 15 AMPS To Rocker Switch To J Box Pilot Main HI LO DC Motor Drive J7860 Light Module J7865 J7864 J7868 Black Brown Red Orange Orange Green To Ground BATTERY PACK Black Bl...

Страница 40: ...y other possible obstructions 4 Contact your gas supplier to check pres sure 5 Have a qualified technician replace pilot line 6 Replace control valve Refer to Parts page 43 7 Checkthatmainpowerisonand...

Страница 41: ...nfiguration 1 Air holes at burner inlet blocked 2 Burner flame holes blocked 3 Improper venting or excessive blockage OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combu...

Страница 42: ...2 3 1 4 4 5 7 8 9 10 12 13 14 15 16 18 17 19 20 11 6 4 4 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Rep...

Страница 43: ...11 J7852 Flextube 1 12 J7853 Burner Gasket 2 13 J7854 Power Module 1 14 J7855 Battery Backup 1 15 J7856 Battery Backup Bracket 1 16 J7857 Valve Bracket 1 17 J7858 Valve NG 1 J7859 Valve LP 1 18 J7860...

Страница 44: ...Superiorfireplaces US com 126718 01_D 44 1 2 3 6 7 7 9 4 12 11 14 13 10 15 8 5 16 17 18 19 21 20 PARTS MODELS DRL4543TEN AND DRL4543TEP...

Страница 45: ...ng Bracket 2 11 J7883 Ceramic Door Assembly 1 12 J7884 Cover Assembly Mesh Linear DV 1 13 J7885 Corner Bracket 4 14 J7886 Side Walls 2 15 J7887 Pebble Pan 1 16 J7888 Rear Wall 1 17 J7889 Rail Barrier...

Страница 46: ...ville TN 37210 Visit us at Superiorfireplaces US com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat pro...

Страница 47: ...urn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a f...

Страница 48: ...ealer name P126718 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...

Отзывы: