Installation
900004-00, 03/2017
Innovative Hearth Products
DRT2000 and DRC2000 Direct-Vent Fireplaces
41
Electronic Fireplace Inspection
To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot fl ame
should engulf the fl ame rod
(
Figure 37
).
14.
Optional: Install the Firebox Liners
1.
See
Page 51
for instructions on
Traditional Only: Installing the Firebox Liners
.
15.
Contemporary Fireplaces: Install the Glass Media
1.
See
Page 51
for instructions on
Contemporary Only: Installing the Glass Media
.
16.
Traditional Fireplaces: Install the Logs, Volcanic Stone, and Glowing Embers
1.
See
Page 52
for instructions on
Installing the logs, volcanic stone, and glowing embers
.
17.
Install the Glass Door
1.
See
Page 55
for instructions on
Installing and removing the glass door
.
18.
Adjust the Air Shutter to Ensure Proper Flame Appearance
WARNING
• Air shutter adjustment should only be performed by a qualifi ed professional service technician.
• Ensure glass door is in place and sealed during adjustment.
CAUTION
• Soot will be produced if the air shutter is closed too much. Any damage due to sooting,
resulting from improperly setting the air shutter, is not covered under the warranty.
• The air shutter rod and nearby appliance surfaces are hot. Exercise caution to avoid injury
while adjusting fl ame appearance.
Flame Appearance and Sooting
The fl ame should be blue at the base, and yellow-orange in the body of the fl ame.
When the fi replace is fi rst lit, the entire fl ame may be blue and will gradually turn yellow-orange during the fi rst 15
minutes of operation. If the fl ame remains blue, or if the fl ame is orange with evidence of sooting (black tip), the air
shutter opening may need to be adjusted.
If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at the
tips of very long orange fl ames. Sooting results in black deposits forming on the logs, fi replace inside surfaces, and
on exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the fl ames and lack of combustion air entering the air shutter
opening. To achieve a warm yellow-orange fl ame with an orange body that does not soot, the shutter opening must
be adjusted between these two extremes.
Figure 36 - Millivolt Pilot
Figure 37 - Electronic Pilot
Thermocouple
Hood
Igniter rod
3/8” (9
mm)
min
Thermopile
Pilot
nozzels
Igniter
Flame Rod
Pilot Hood