NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Electronic Appliance Checkout

To light the burner, refer to the lighting instruc-
tions on 

page 14 and 15

.  Ensure the ignitor

lights the pilot. The pilot flame should engulf the
flame sensor as shown in 

Figure 10

Figure 10

With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If you
should experience any problem, first refer to the
trouble shooting guide in this manual. If problem
persists, contact your Lennox distributor.

WIRING DIAGRAMS

Wiring diagrams are provided here for refer-
ence purposes only.  This information is also
provided on schematics attached directly to
the appliance on a pullout panel located within
the control compartment.

CAUTION:  LABEL ALL WIRES PRIOR TO DIS-
CONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS APPLIANCE OPERATION.

WARRANTY

Your gas appliance is covered by a limited twenty
year warranty. You will find a copy of the war-
ranty accompanying this manual.  Please read
the warranty to be familiar with its coverage.

REPLACEMENT PARTS

A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.

Normally, all parts should be ordered through
your Lennox distributor or dealer. Parts will be
shipped at prevailing prices at time of order.

When ordering repair parts, always give the
following information:

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace.  Please
contact your Lennox dealer for any questions or concerns.  For the number of your nearest Lennox
dealer, please call 800-731-8101

Your Fireplace's Model Number _______________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed __________________________

The Type of Gas Your Fireplace Uses ___________________________________

Your Dealer's Name _________________________________________________

If you encounter any problems or have any
questions concerning the installation or appli-
cation of this system, please contact your dis-
tributor, or Lennox directly:

LHP

1110 West Taft Avenue • Orange, CA  92865

1.

 The model number of the appliance.

2.

 The serial number of the appliance.

3.

 The part number.

4.

 The description of the part.

5.

 The quantity required.

6.

 The installation date of the appliance.

Retain this manual. File it with your other docu-
ments for future reference.

Proper Flame
Adjustment

Hot Surface
Igniter

Flame Rod

Ground
Electrode

3/8 To 1/2 Inch

(9 mm to 13 mm)

1. If any of the original wire as supplied must be replaced,

1.  

it must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Junction Box

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-100 and FBK-200 Kits

R

W

BL

OPT

BLOWER

G

W

*OPTIONAL

ACCESSORY

SWITCH

120

 VAC.

BK

W

Gas Valve

B

R

IGNITER

PILOT

ASSEMBLY

Break Off

Tab

BK

G

*Blower speed control switch is provided in FBK200 blower kit.

Outlet Box

Green Ground

Screw

Hot side of Outlet

Schematic Representation Only

**ON/OFF Switch (Integral

with Gas Valve)

**Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

 OR OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

Red

pigtail

Black

pigtail

White Wire
to Opposite

Side

G

1. If any of the original wire as supplied must be replaced,

1.  

it must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-250 Kits

R

WH

BL

OPT

BLOWER

G

W

120

 VAC.

BK

W

Gas Valve

B

R

IGNITER

PILOT

ASSEMBLY

BK

G

Outlet Box Green

Ground Screw

Hot side of Outlet

Schematic Representation Only

*ON/OFF Switch (Integral

with Gas Valve)

White Wire

To Opposite

Side

Optional FBK-250

Module

*Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

G

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

 OR OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

 Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,
it must be replaced with

 

Type AWM 105

°

C, 18 GA. wire.

Thermopile

TH

TP

TH

TP

*TWIST WIRES “A” AND “B” TOGETHER TO OPERATE UNIT

SOLELY BY MANIPULATING THE GAS VALVE CONTROL KNOB;
OR CONNECT WIRES TO  OPTIONAL UNIT-MOUNTED ON/OFF

SWITCH OR WALL-MOUNTED ON/OFF SWITCH OR

THERMOSTAT TO OPERATE UNIT.

*UNIT-MOUNTED ON/OFF SWITCH (Accessory Option)

 OR WALL-MOUNTED ON/OFF SWITCH (Accessory Option)

 OR THERMOSTAT (Accessory Option)

OR REMOTE CONTROL RECEIVER (Accessory Option)

A

B

Содержание CDCL-CEN

Страница 1: ...ement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service dos incendies L installationetservicedoit tr...

Страница 2: ...d at the time of appliance installation The electronic appliances are designed to op erate on either natural or propane gas An electronic intermittent pilot system provides safe efficient operation Ex...

Страница 3: ...eans an optional unit mounted ON OFF control switch Millivolt appliances only an optional wall mounted ON OFF con trol switch or an optional remote control The unit mounted ON OFF control switch may b...

Страница 4: ...lower control compartment clean by vacuuming or brushing at least twice a year Morefrequentcleaningmayberequireddueto excessive lint from carpeting bedding materi als etc It is important that control...

Страница 5: ...eanysurface build uponpilotandburnerassembly Cleanthe pilot nozzles ignitor flame rod and hood with a soft brush Ensure the pilot flame engulfs the flame sensor as shown Inspect the vent system at the...

Страница 6: ...hutter opening must be adjustedbetweenthesetwoextremes Nosmoke orsootshouldbepresent Repositionthelogset if the flames impinge on any part of it If the log set is properly positioned and sooting condi...

Страница 7: ...he burners to simulate ashes Maintain a in gap between the bottom of the horizontal grate section and the top of the pile of decorative volcanic stone Place a few dime sized pieces of the glowing embe...

Страница 8: ...appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance Retain this manual File it with your other docu ments for future reference P...

Страница 9: ...on the transmitterispressed asignallightilluminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all millivolt ignition systems as well as electronic ignitio...

Страница 10: ...of view and is perfect for use in high volume areas such as lobbies and model homes where limited access to the appliance On Off switch is desirable This kit can be retrofitted to previously installed...

Страница 11: ...top and bottom edges The DTK provides a touch of elegance to the appliance The door frame kit can be retrofitted onto previously installed appliances Louvers Kits Decorative louvers are available for...

Страница 12: ...ntrol knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pilot lights Continue to hold the control knob in for about 1 minutes after the...

Страница 13: ...hant l allume gaz tincelle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pendant environ 90 secondes apr s l allumage de la veilleuse Rel ch...

Страница 14: ...of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment door 3 Tu...

Страница 15: ...n d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournezlamanetteder glagedugaz lapositiond arr t OFF 6 Atte...

Страница 16: ...only be accomplished by a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 9 on page 7 Check burner orifice for stoppage and remove C...

Страница 17: ...iring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24...

Страница 18: ...r e w o L C 5 0 4 2 9 B L 2 2 1 1 5 d n a r B e t a l p e m a N 1 0 3 9 L 6 5 2 2 1 1 6 t e S g o L 1 0 2 6 L 9 6 1 1 1 1 7 s r e b m E g n i w o l G f o g a B 3 5 L 8 8 1 1 1 1 8 e n o t S c i n a c...

Страница 19: ...5 L 4 7 1 1 0 7 5 L 4 7 1 5 3 e b u T t o l i P 1 0 6 5 L 4 7 1 1 0 6 5 L 4 7 1 6 3 e l b a C d n A e d o r t c e l E 1 0 8 5 L 4 7 1 1 0 8 5 L 4 7 1 7 3 e c i f i r O 1 0 0 8 J 0 6 2 1 0 2 5 L 9 1 2...

Страница 20: ...nd also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue Orange CA 92865 REPLACEMENT PARTS Model CDPF Shown see table o...

Отзывы: