background image

www.www.SuperiorFireplaces.US.com

126826-01A

23

OPERATION

 WARNING:

•  If  fireplace  has  glass  doors, 

never operate this heater with 

glass doors closed. If you op-

erate heater with doors closed, 

heat buildup inside fireplace 

will cause glass to burst. Make 

sure there are no obstructions 

across openings of fireplace.

•  You must operate this heater 

with a fireplace screen in 

place. Make sure fireplace 

screen is closed before run-

ning heater.

Note: Home owners generally prefer to oper-

ate their heater with the chimney damper 

closed. This will put all the heat into the room. 

However, there may be times you will desire 

the full flames of the HI heat setting but will 

find the heat output excessive. You can open 

the chimney damper (if you have one) fully or 

partially to release some of the heat.

 WARNING: Damper handle 

will be hot if heater has been 

running. 

1.  STOP! Read the safety information.
2.  Make sure equipment shutoff valve is fully 

open.

3.  Turn control knob clockwise 

 to the 

OFF position.

4.  Wait five (5) minutes to clear out any gas. 

Then  smell  for  gas,  including  near  the 

floor. If you smell gas, STOP! Follow B in 

the safety information. If you don’t smell 

gas, go to the next step.

5.  Turn control knob counterclockwise 

 to the PILOT position. Press in 

control  knob  for  five  (5)  seconds  (see 

Figure 36).

FOR YOUR SAFETY  

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, 

a  fire  or  explosion  may  result 

causing property damage, per-

sonal injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting 

the pilot, follow these instructions 

exactly.

B.  BEFORE LIGHTING smell all around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If the knob will not push in or turn by 

hand, don’t try to repair it, call a quali-

fied service technician or gas supplier. 

Force or attempted repair may result in 

a fire or explosion.

D.  Do not use this appliance if any part 

has been under water. Immediately call 

a qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

LIGHTING 

INSTRUCTIONS

NOTICE: During initial operation 

of new heater, burning logs will 

give off a paper-burning smell. 

Orange flame will also be pres

-

ent. Open damper or window to 

vent smell. This will only last a 

few hours.

Figure 36 - Control Knob and Ignitor 

Button Location

Control Knob

Ignitor Button

Содержание BGE18NT

Страница 1: ...ireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs This is an unvented gas fired heater It uses air oxygen from the room in which it is ins...

Страница 2: ...uel burning masonry or UL127 factory built fireplace or in a listed ventless firebox enclo sure It is design certified for these installations in accordance with ANSI Z21 11 2 Exception DO NOT install...

Страница 3: ...ation of this fireplace WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use with this heater...

Страница 4: ...rst Make sure there are no obstructions across openings of fireplace 8 To prevent the creation of soot follow the instructions in Cleaning and Maintenance page 29 9 Before using furniture polish wax c...

Страница 5: ...s sembly The data plates contain important warranty and safety information 1 Remove logs and heater base assembly from cartons Note Do not pick up heater base assem bly by burners This could damage he...

Страница 6: ...onths home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning ap pliances ne...

Страница 7: ...s or openings add the volume of these rooms to the total volume of the space 2 Multiply the space volume by 20 to determine the maximum Btu Hr the space can support _________ volume of space x 20 Maxi...

Страница 8: ...2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation...

Страница 9: ...though this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventila tion page 6 NOTICE Thisheater isi...

Страница 10: ...will ensure safe installation into a masonry UL127 listed manufactured fireplace or listed vent free firebox Minimum Clearances For Side Combustible Material Side Wall and Ceiling A Clearances from t...

Страница 11: ...nimum clearances If Using Mantel You must have noncombustible material s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1 2 thick With sheet metal...

Страница 12: ...nstalled at Floor Level Figure 7 Minimum Mantel Clearances When Using Hood FLOOR CLEARANCES A If installing appliance on the floor level you must maintain the minimum distance of 14 to combustibles se...

Страница 13: ...d if allowed by local codes sealant resistant to propane LP gas not provided electric drill with 3 16 masonry drill bit 1 Apply pipe joint sealant lightly to male threads of gas fitting provided Con n...

Страница 14: ...UTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heate...

Страница 15: ...ance main gas valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage heater regulator 2 Cap off open end of gas pipe where e...

Страница 16: ...Location Propane LP Supply Tank Equipment Shutoff Valve Open Closed Equipment Shutoff Valve Gas Meter Figure 16 Checking Gas Joints Natural Gas Only Thermostat Gas Valve or Control Valve Location Equi...

Страница 17: ...4 Position front left log against left side of grate prongs see Figure 18 5 Place middle right log over front right and bottom logs as shown in Figure 19 Be Rear Log Grate Prongs Figure 18 Installing...

Страница 18: ...trols LBG 18 24 30 SM MODELS LBG36 SM MODELS Figure 21 Correct Log Placement CONCRETE LOG MODELS LBG 18 24 30 BM Note Your appliance may vary from model shown but log placement will be the same 1 Plac...

Страница 19: ...ace log as shown in Figure 25 The right ember bed logs for 18 D 072 has a groove on the side that sets on the ember bed pan and the back of the log needs to rest against the front of the base Make sur...

Страница 20: ...burner out of position while installing this log 8 Rest the rear log 18 D 069 24 30 D 043 on the chassis behind the rear burner as shown in Figure 29 The bottom of the rear log will sit into the rear...

Страница 21: ...m of each ember chunk has a hole for securing the ember chunk in place when it is placed over a shoulder screw Place the ember chunks as shown in Figure 33 on page 22 by placing the ember chunk with t...

Страница 22: ...ers for BGE Series Flat Front Burner Ember Material Figure 35 Placement of Rock Wool for BGE Series shown with Platinum Bright Embers Rock Wool Figure 33 Ember Chunk Placement BGE2436 Series Ember Chu...

Страница 23: ...ARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by ha...

Страница 24: ...Turn control knob counterclockwise to desired heating level The burn ers should light Set control knob to any heat level between HI and LO 9 To leave pilot lit and shut off burners only turn control k...

Страница 25: ...Pattern Your pilot may vary from pilots shown Thermocouple Thermocouple Pilot Burner BURNER FLAME PATTERN Figure 40 shows correct burner flame pat tern Figure 41 shows incorrect burner flame pattern W...

Страница 26: ...or at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 42 3 Blow air through the ports slots and holes in the burner 4 Check inje...

Страница 27: ...is located on the gas valve assembly This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace appli cations If positioning the thermostat sensing...

Страница 28: ...ile in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ig...

Страница 29: ...pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company B Clean...

Страница 30: ...and let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 t...

Страница 31: ...leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Thermostat sensi...

Страница 32: ...Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C BGE2436PT Rating Variable 23 000 39 000 Btu Hr Type Gas Propane LP Ignition Electronic M...

Страница 33: ...PT QTY 120466 01 Flex Tube 1 100563 01 Warning Plate 1 101054 01 Lighting Instruction Plate 1 100639 12 Caution Decal 1 101137 02 Hardware Kit 1 GA6060 Lava Rock 1 125557 01 Left Ember Chunk 1 1 12555...

Страница 34: ...Gas Valve Service Kit 1 101329 31 Gas Valve Service Kit 1 101329 26 Gas Valve Service Kit 1 9 Plate NG Conversion 1 10 111435 01 Electronic Ignitor 1 11 112465 01 Front Ramp Burner 1 112465 02 Front...

Страница 35: ...5 of this manual 1 2 3 4 5 6 7 KEY NO MODEL NUMBER DESCRIPTION QTY LBG18 SM LBG24 SM LBG30 SM 1 121699 05 121699 11 121699 17 Front Right Log 1 2 121699 04 121699 10 121699 16 Front Left Log 1 3 12169...

Страница 36: ...s manual KEY NO MODEL NUMBER DESCRIPTION QTY LBG36 SM 1 121699 13 Bottom Log 1 2 125683 01 Middle Right Log 1 3 121699 15 Middle Left Log 1 4 121699 20 Front Left Log 1 5 121699 21 Front Right Log 1 6...

Страница 37: ...5851 04 D 073 125852 04 D 048 125852 04 D 048 Log Left Front Ember Bed 1 5 125851 05 D 072 125852 05 D 047 125852 05 D 047 Log Right Front Ember Bed 1 6 125851 06 D 066 125852 06 D 040 125852 06 D 040...

Страница 38: ...ICAL SERVICE You may have further questions about instal lation operation or troubleshooting If so contact INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 When calling please have your model and serial n...

Страница 39: ...ll produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product...

Страница 40: ...EP THIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________...

Страница 41: ..._____________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________________...

Страница 42: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 43: ..._____________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________________...

Страница 44: ...P126826 01 126826 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com...

Отзывы: