PRODUCT IDENTIFICATION
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the
absence of local codes, use the latest edition of The National Fuel
Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Figure 1 - B-Vent Fireplace
Top Louver Panel
Glass
Door
Assembly
Bottom
Louver
Panel
Junction Box
(Electronic
Ignition Only)
Control
Valve
Ember Tray
Log Set
Nailing
Flange
4" B-Vent
Flue Collar
PRODUCT FEATURES
These are a few facts that can help you understand and enjoy your
vented decorative fireplace:
• The BCT2536TEN and BCT2536TEP series of vented decorative
fireplaces may be recessed into an exterior chase, an interior
flush wall enclosure or a framed-in corner installation.
• Models BCT2536TMN and BCT2536TMP are equipped with a
millivolt gas control system that does not require electricity to
operate. A piezo ignitor is provided to light the pilot without using
matches or lighters.
• Models BCT2536TEN and BCT2536TEP are equipped with an elec
-
tronic ignition system that requires 120 VAC to operate. An electrode
ignitor automatically lights the pilot flame when the fireplace is turned
on.
• These fireplaces can accept any approved 4" B-Type venting system
and must be terminated vertically through the roof using a listed
type vent cap only. See venting instructions starting on page 8 for
proper venting requirements.
• These vented fireplaces require indoor air for combustion and must
be installed in a room of sufficient size to provide adequate fresh
air for safe and proper operation. The room intended for instal-
lation must be of sufficient size to meet the requirements for an
unconfined space as defined in the National Fuel Gas Code, ANSI
Z223.1/NFPA 54. Air for Combustion and Ventilation. If sufficient
air for combustion is not available a makeup air kit model AK4 may
be required to provide outside air to this appliance. Check your
local codes as to specific requirements for make up air.
• This fireplace may be installed in any room of the house provided
all local codes and these installation instructions are followed.
PRE-INSTALLATION PREPARATION
LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efficient location for your INNOVA-
TIVE HEARTH PRODUCTS, LLC (IHP) B-vent fireplace. Make sure
that rafters and wall studs are not in the way of the venting system.
Choose a location where the heat output is not affected by drafts, air
conditioning ducts, windows or doors. Figure 2 shows some com-
mon locations. Be aware of all restrictions and precautions before
deciding the exact location for your fireplace and termination cap.
When deciding the location of your fireplace, follow these rules:
• Do not connect this fireplace to a chimney flue servicing a separate
solid fuel burning fireplace or appliance.
• Do to high temperatures, do not locate this fireplace in high traffic
areas, windy or drafty areas, or near furniture or draperies.
• Proper clearances must be maintained.
• If your fireplace is to be installed directly on carpeting, vinyl, tile or
any combustible material other than wood, it must be installed on a
metal or wood panel extending the full width and depth of the fireplace
(see Figure 3).
• Only trim kits supplied by IHP shall be used in the installation of
this fireplace, see Accessories, page 30.
• Do not install aftermarket vent dampers. Manual or automatic vent
dampers are not approved for use with this appliance.