NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Periodically

 (After the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

Cleaning Firebox Interior

Check Flame Patterns and Flame Height

Checking Vent System

Cleaning Front Glass Enclosure Panel

Homeowner

Homeowner

Homeowner

Homeowner

Carefully remove logs, Rockwool and volca-
nic stone if used.  Vacuum out interior of the
firebox.  Clean firebox walls and log grate.
Replace logs, Rockwool and volcanic stone
as detailed in this manual.

Maintenance Task

Accomplishing Person

Procedure

Inspecting/Cleaning Burner, Logs
and Controls

Check Flame Patterns and Flame Height

Inspecting/Cleaning Pilot and Burner

Checking Vent System

Appliance Checkout

Replacing Rockwool Ember Materials

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Homeowner/Qualified Services Technician

Inspect valve and ensure it is properly operat-
ing.  Check piping for leaks.  Vacuum the control
compartment, fireplace logs and burner area.

Refer to 

Figures 12 (B-500), 13 (B-600) or

14 (B-800) on page 9

  and verify the flame

pattern and height displayed by the appli-
ance conforms to the picture. Flames must
not impinge on the logs.

Refer to 

Figure 9 (

SIT Millivolt

), Figure 10

(

Honeywell Millivolt

) or Figure 11 (

Elec-

tronic

) on page 8

.  Remove any surface

build-up on pilot and burner assembly.  Wipe
the pilot nozzles, ignitor/flame rod and hood.
Ensure the pilot flame engulfs the flame
sensor as shown.

Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction.  Look for any signs of disloca-
tion of the vent components.

Perform the appropriate appliance checkout
procedure detailed in this manual.

Remove old ember materials and vacuum the
screened rockwool placement area.  Place
new rockwool as described in this document.

Clean as necessary following the directions
provided in this manual.  

DO NOT  TOUCH OR

ATTEMPT TO CLEAN GLASS WHILE HOT

.

Inspect the vent system at the top and at the
base (within the firebox) for signs of block-
age or obstruction.  Look for any signs of
dislocation of the vent components.

Refer to 

Figures 12 (B-500), 13 (B-600) or

14 (B-800) on page 9

  and verify the flame

pattern and height displayed by the appli-
ance conforms to the picture. Flames must
not impinge on the logs.

Maintenance Schedule

Annually

 (Before the onset of the Burning Season)

f i r e - p a r t s . c o m

Содержание B-500CEN

Страница 1: ...e gaz Ne pas tenter d allumer d appareil Netouchez aucuninterrupteur Nepasvousservir des t l phones se trouvant dans le batiment o vous vous trouvez Evacuez la pi ce le b timent ou la zone Appelez imm...

Страница 2: ...page 17 Troubleshooting Guide Electronic page 18 Replacement Parts List page 19 Maximum manifold pressure is 3 5 in w c 0 87 kPa for natural gas and 10 in w c 2 49 kPa for LP Propane gas The following...

Страница 3: ...t the ON OFF rocker switch will control the appliance ON OFF operation To operate Toggle the switch between its ON and OFF positions OPERATION AND CARE OF YOUR APPLIANCE Appliance operation may be con...

Страница 4: ...t least twice a year Morefrequentcleaningmayberequireddueto excessive lint from carpeting bedding materi als etc It is important that control compart ments burners and circulating air passage ways of...

Страница 5: ...dges of the glass door 6 If the smoke is not drawn towards the edges of the glass door turn off the appli ance and call a qualified service technican Outside Air Control Lever Outside Air Control Leve...

Страница 6: ...nd verify the flame pattern and height displayed by the appli ance conforms to the picture Flames must not impinge on the logs Refer to Figure 9 SIT Millivolt Figure 10 Honeywell Millivolt or Figure 1...

Страница 7: ...E CRACKED OR BROKEN GLASSWITHANYMATERIALSOTHERTHAN THOSE PROVIDED BY THE APPLIANCE MANUFACTURER THE GLASS DOOR OF THIS APPLIANCE MUSTONLYBEREPLACEDASACOMPLETE UNIT AS PROVIDED BY THE MANUFAC TURER DO...

Страница 8: ...ght the burner refer to the lighting in structions on pages 13 and 14 for Honeywell and SIT millivolt gas valves ELECTRONIC Proper Flame Adjustment Pilot Nozzle 3 8 To 1 2 Inch 9 mm to 13 mm Ground El...

Страница 9: ...NTHEFIREPLACE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUS TION SOOTING AND POOR FLAME QUALITY WARNING LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OF...

Страница 10: ...quantity required 6 The installation date of the appliance Honeywell and SIT Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18...

Страница 11: ...etric of English units flame indicator and clock Fully programmable the Model RCL T allows for command over nearly all operational and temperature variables using the hand held remote control transmit...

Страница 12: ...a P e c a F n a e l C l e d o M t i n U o N o N g o l a t a C o N l e d o M t i K 0 0 5 B 6 7 L 0 8 0 5 5 K P F C 0 0 6 B 7 7 L 0 8 0 6 6 K P F C 0 0 8 B 8 7 L 0 8 0 8 8 K P F C s t i K e m a r F r o...

Страница 13: ...control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pilot ligh...

Страница 14: ...Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagnie de gaz appelez le serv...

Страница 15: ...s appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been u...

Страница 16: ...specter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la positi...

Страница 17: ...ll on page 8 Check burner orifice for stoppage and remove Checkthermopilewithmillivoltmeter Takereadingatthermo pile terminals of gas valve Should read 325 millivolts mini mum with optional wall switc...

Страница 18: ...tage Power Low Voltage Transformer Limit Controller Thermostat Wiring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burne...

Страница 19: ...4 1 3 4 t i K y l b m e s s A r o t i n g I 4 5 L 7 8 1 4 5 L 7 8 1 o N N O I T P I R C S E D 0 0 5 B 0 0 6 B 0 0 8 B o N t r a P y t Q o N t r a P y t Q o N t r a P y t Q y l b m e s s A e c a l p e...

Страница 20: ...design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue Orange CA 92865 REPLAC...

Отзывы: