Superior AccuTrak VPE Скачать руководство пользователя страница 4

Superior Signal Company LLC                                       AccuTrak

®

 VPE 

User’s Manual

 © 2015 

 

 

INTRODUCTION 

 

Congratulations  on  your  purchase  of  the  Superior  AccuTrak

®

  Model  VPE  or 

VPE-GN  ultrasonic  leak  detector!    The  AccuTrak

®

  VPE  is  just  one  model  in 

the  AccuTrak

®

  line  of  high  quality  ultrasonic  instruments  that  are  available 

exclusively from Superior Signal Company LLC.  The Superior AccuTrak

®

 line 

offers  an  incredible  range  of  capabilities,  using  patented  technology  that 
provides real-world performance far superior to any other instruments in their 
class,  yet  at  amazingly  affordable  prices.   

That’s  why  we  say: 

You  have  to 

Hear  it  to  Believe  it!    With  AccuTrak

®

  you  simply  get  the  job  done  faster, 

easier, and at a lower cost. 

The Superior AccuTrak

®

 Model VPE-GN is a special version of the VPE, with 

all  the  same  technology  and  specifications 

  plus  the  unique  ability  to  place 

the  actual  sensor  head  directly  into  hard-to-

reach  places.    This  9”  flexible 

GooseNeck  allows  you  to  find  even  the  smallest  leaks  in  blind  spots  behind 
obstructions  or  inaccessible  places  inside  machinery.    The  VPE-GN  cannot 
use the Touch Probe accessory to hear internal ultrasound, so references to 
this capability / option in this manual do not apply to the VPE-GN instrument.  
Also please note that the GooseNeck is NOT removable, and any attempt to 
remove or modify the GooseNeck will cause damage and void the Warranty. 

The AccuTrak

®

 VPE is the only ultrasonic instrument specifically designed for 

air-conditioning and refrigeration leak detection.  Refrigeration is a unique field 
that  requires  very  high  performance  leak  detectors.    It  requires  both  vacuum 
and pressure leak detection at very low flow rates.  Ultrasonic inspection is the 
only  test  system  that  can  simultaneously  detect  both.    The  AccuTrak

®

  is  a 

unique  solution  to  the  many  problems  typically  encountered  with  traditional 
methods of leak detection.  The instrument offers advantages which will result 
in significant time and cost savings.  The AccuTrak

®

 VPE is the ideal tool for 

detecting  both  vacuum  and  pressure  leaks  of  any  refrigerant.    Because  the 
instrument detects sound, it is gas independent.  This means the  AccuTrak

®

 

can even detect dry nitrogen gas leaks. 

Enjoy your new instrument!  It will eliminate the many hours of frustration that 
you have experienced while trying to locate a leak in a gas saturated area, on 
a windy roof top unit, or on a system under negative pressure (vacuum).  It will 
also  eliminate  the  need  to  use  tracer  gasses  which  can  be  ozone  depleting 
when  vented.    The  AccuTrak

®

  VPE  is  very  easy  to  use  because  it  uses  a 

totally  different  technology  than  the  "sniffers"  and  torches  that  you  probably 
are used to.  To eliminate any future frustration, please take a few minutes to 
read this manual and understand the operation of the AccuTrak

®

Содержание AccuTrak VPE

Страница 1: ...Models VPE VPE GN 3rd Generation USER S MANUAL www SuperiorSignal com Superior Signal Company LLC 2015 ...

Страница 2: ...2 Peak Hold Display the new Peak Hold function on the display allows you to find leaks and faults faster and better so you get the job done quicker and easier This great feature can be found on instruments costing several times more but it is unique for this class of instrument 3 Over Range Audio Alarm this unique new feature allows you to keep your eyes on what you are measuring rather than on yo...

Страница 3: ...ION 7 BACKGROUND NOISE 9 Methods of reducing background noise interference 9 TIPS ON USE 10 TROUBLESHOOTING GUIDE 10 OTHER APPLICATIONS 11 ELECTRICAL ARCING 11 DUCTWORK 11 PNEUMATICS AND HYDRAULICS 11 BEARINGS VALVES STEAM TRAPS MECHANICAL 11 TOUCHPROBE ACCESSORY 12 OPTIONAL SOUND GENERATOR 12 BATTERY INSTALLATION 13 CARE AND MAINTENANCE 13 CALIBRATION 13 WARRANTY 14 ...

Страница 4: ...attempt to remove or modify the GooseNeck will cause damage and void the Warranty The AccuTrak VPE is the only ultrasonic instrument specifically designed for air conditioning and refrigeration leak detection Refrigeration is a unique field that requires very high performance leak detectors It requires both vacuum and pressure leak detection at very low flow rates Ultrasonic inspection is the only...

Страница 5: ... out of a tire The sound we can hear is less than a third of the total spectrum of frequencies generated The sound in small leaks is mostly ultrasonic Humans cannot hear this because it is above the human hearing range In order for a leak to generate ultrasound the flow through the leak path must be turbulent For this to happen the velocity that a gas is moving through the leak point must be high ...

Страница 6: ...generate enough sound to be heard several feet away For a leak to happen there must be an opening in the system that carries a gas or fluid Normally these openings are not clean smooth holes but passages through cracks with many jagged edges and internal chambers Fluid or gas escaping through an orifice like this is forced into turbulence random circular like motions Inside a tube where a gas may ...

Страница 7: ...ssure created by the leak will determine its ability to be detected ultrasonically When comparing to traditional refrigerant detectors that are rated to detect 0 5 oz per year remember these instruments were tested under controlled laboratory conditions and the ability to actually locate such a small trace of gas especially in a windy outdoor environment is extremely limited It is physically impos...

Страница 8: ...noise Pressing the ON OFF button again momentarily will toggle on or off the Peak Hold function of the display together with a confirmation beep in the headphones Peak Hold can be useful to better observe the maximum strength signals being detected and help find Leaks and Faults To turn off the instrument press and hold the ON OFF button for at least two seconds until it goes off When using the in...

Страница 9: ...n the right path since the indications will increase in the direction of the leak Other Important Information Remember to turn off the instrument when you are done using it or the battery will run down When the battery becomes weak enough that performance may be reduced the instrument will provide a visual signal on the display and a beep in the headphones and then the instrument will shut off The...

Страница 10: ...nguish the difference between the two signals Practice listening to different components of your system as this will help you to identify the sound of a leak from other normal operational sounds Methods of reducing background noise interference Placing the flexible wave guide into the sensor port makes the reception of the AccuTrak more directional This shields the sensor from competing sounds ent...

Страница 11: ...mputer terminals emit a high frequency humming sound This is not an electrical field interfering with the operation of the AccuTrak VPE it is an actual sound that the unit is hearing To confirm this place your finger over the sensor hole and the sound will disappear In almost all cases this sound is not severe enough to interfere with leak detection Hissing noise There is a certain amount of hiss ...

Страница 12: ...ized duct system Pneumatics and Hydraulics Leaks are quite common in pneumatic systems controls hoses tools fittings The AccuTrak VPE can easily find the rushing sound of the leak Small hydraulic leaks can be difficult to find but the AccuTrak VPE will allow you to hear these leaks with ease When testing for hydraulic leaks use the yellow waveguide to prevent any fluid from entering the sensor Int...

Страница 13: ... is a very useful accessory to detect leaks in enclosures gaskets or seals which are not under pressure The Sound Generator has a selectable output Constant tone can be used in most situations while the Burst Tone mode is more easily identified in loud industrial environments Place the Sound Generator inside a vessel such as a walk in freezer or refrigerated trailer It emits a powerful 115dB ultra...

Страница 14: ...uTrak VPE can be cleaned with a towel using dish soap and damp cloth Remove the battery and close the door before cleaning Do not allow water to enter the unit especially the front where the sensor is located After cleaning dry the unit with a paper towel Any automotive vinyl cleaner on a piece of cloth will restore the luster The same procedure can be used on the carrying case If you plan to stor...

Страница 15: ...are at the sole discretion of Superior Signal Company LLC Maximum liability under any circumstance shall be limited to replacement of unsatisfactory product Recommendations and product information are believed to be accurate but the furnishing of it does not constitute the making of a good process warranty of Seller Superior warrants that this product conforms to the product description contained ...

Отзывы: