Applicable Codes and Standards 

 
Installation of this heater shall be in accordance with local codes, or in the absence of local codes, the National 
Electrical Code, NFPA 70, or the Canadian Electrical Code, Part 1, C22.1. 
 
The eWAVE heater is designed and manufactured for residential / commercial heating applications for indoor and 
outdoor use, according to the Standard for Fixed and Location-Dedicated Electric Room Heaters, UL 2021, and the 
Canadian Standard for Electric Air Heaters, CSA C22.2 No. 46. 

 
 

Technical Specifications 

 

 

Model 

Output 

Wattage 

Supply 

Voltage 

Supply 

Phase 

Supply Amp 

Draw 

Supply Voltage / 

Connection 

Dimensions 

Weight 

EW30L20Y 

3,000 W 

208 V 

8.3 A x 3 

3

Φ

4W, 208Y/120Vac 

73x10x3“ 

(186x25x7.5 cm) 

27.6 lbs (12.5 Kg) 

EW30L24D 

3,000 W 

240 V 

7.2 A x 3 

3

Φ

3W, 240Vac 

 

73x10x3“ 

(186x25x7.5 cm) 

27.6 lbs (12.5 Kg) 

EW45L24D 

4,500 W 

240 V 

10.8 A x 3 

3

Φ

3W, 240Vac 

 

96x10x3“ 

(243x25x7.5 cm) 

35.9 lbs (16.3 Kg) 

EW45L48D 

4,500 W 

480 V 

5.4 A x 3 

3

Φ

3W, 480Vac 

 

96x10x3“ 

(243x25x7.5 cm) 

35.9 lbs (16.3 Kg) 

EW45L48Y 

4,500 W 

480 V 

5.4 A x 3 

3

Φ

4W, 480Y/277Vac 

96x10x3“ 

(243x25x7.5 cm) 

35.9 lbs (16.3 Kg) 

EW45L60D 

4,500 W 

600 V 

4.3 A x 3 

3

Φ

3W, 600Vac 

 

96x10x3“ 

(243x25x7.5 cm) 

35.9 lbs (16.3 Kg) 

EW45L60Y 

4,500 W 

600 V 

4.3 A x 3 

3

Φ

4W, 600Y/346Vac 

96x10x3“ 

(243x25x7.5 cm) 

35.9 lbs (16.3 Kg) 

Содержание EW30L20Y

Страница 1: ...ich apply to electrical wiring comprise the basic information needed to complete the installation These criteria must be thoroughly understood before proceeding Only personnel who have been trained an...

Страница 2: ...ns for indoor and outdoor use according to the Standard for Fixed and Location Dedicated Electric Room Heaters UL 2021 and the Canadian Standard for Electric Air Heaters CSA C22 2 No 46 Technical Spec...

Страница 3: ...NS CAUTION High temperature risk of fire keep electrical cords drapery furnishings and other combustibles at least 3 feet 0 9 m from the front of the heater and away from the side and rear 1 This appl...

Страница 4: ...ous harm from an ongoing electric shock a Ground Fault Circuit Interrupter GFCI with rated earth leakage operation not exceeding 30mA must be fitted upstream on the supply line Additionally for ensuri...

Страница 5: ...ture 4 Building materials with low heat tolerance i e plastics vinyl siding canvas tri ply etc may be subject to degradation at lower temperatures It is the installer s responsibility to ensure that a...

Страница 6: ...fixed to the wall or to the ceiling by means of the provided supports Ensure that the wall where you intend to install the heater is solid and that no electrical cables or water pipes pass behind it 1...

Страница 7: ...brackets in position by tightening the safety screws 6 Tilt the heater until you can insert a screw in the hole Now the junction box is easy to access 7 Connect the power according to the following d...

Страница 8: ...eWAVE Page 8 LT288 April 09 2020 9 Once the wiring is completed close the connection box with the appropriate screws making sure to position the gaskets between the box and the cover as shown in the...

Страница 9: ...y the user and not by unsupervised children 1 It is important that eWAVE units are regularly cleaned to ensure long and efficient operating life 2 To clean use a soft damp cloth and then dry thoroughl...

Страница 10: ...WAVE Hanging Brackets Kit Part ES314 Item Description Quantity 1 Heater Bracket 2 2 Wall Bracket 2 3 M4x10mm Phillips Pan Scr S S 8 4 M4 Nut S S 4 eWAVE Junction Box Lid Gasket Kit Part ES315 Item Des...

Страница 11: ...nty obligation or liability Provision of this warranty is subject to The eWAVE product must be installed in accordance with the installation instructions and relevant electrical standards and codes Th...

Страница 12: ...Series eWAVE Page 12 LT288 April 09 2020 THIS PAGE LEFT INTENTIONALLY BLANK...

Отзывы: