background image

 

NOTICE:

 

Height and/or piping restriction will reduce the pump output performance.  See the 

performance chart below to insure you have the proper pump for your application.  Whenever 
possible use the same size or larger pipe as the pump discharge for optimum performance.  
Reducing the pipe size will not harm your pump; it will just reduce the output. 
 

PERFORMANCES 

*Performance ratings are based on using a 27M, 12 volt deep cycle marine battery with a 100 
Ah rating 

 

 

 

 
 

SPECIFICATIONS

 

Motor 

 

 

 

 

 

 

12 volt DC 

Amps 

 

 

 

 

 

 

13 

Battery Requirements  

 

 

 

 

12 Volt Deep Cycle Marine 

Low Voltage Shut off   

 

 

 

 

10 Volts 

Solids Handling 

 

 

 

 

 

1/8” 

Discharge Size 

 

 

 

 

 

1-1/4” or 1-1/2”  

Battery Charger 

 

 

 

 

 

2 amp 

Liquid Temperature Range 

 

 

 

 

32°-120°F (0°-49°C) 

Warranty   

 

 

 

 

 

1 Year 

 

Model #

 

Output in gallons per minute at listed discharge

 

height above pumping level

 

0’

 

5’

 

10’

 

15’

 

20’

 

92900, 92910

 

23

 

22

 

18

 

13

 

8

 

Содержание 92900

Страница 1: ...OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK UP SYSTEM Models 92900 92910...

Страница 2: ...ISK OF ELECTRICAL SHOCK Do not plug in or unplug the AC transformer while standing on a wet floor If basement floor is wet disconnect the power before walking on the floor WARNING Do not use the power...

Страница 3: ...cts can cause a carbon monoxide CO detector to give a false alarm When installing this system position the battery as far away from the CO detector as possible DO NOT move or remove CO detectors from...

Страница 4: ...tools and components of this system away from the work area when cutting pipe If any components get wet make sure they are dry before installing 7 If your primary pump does not have a check valve in o...

Страница 5: ...rimary pump Make sure the on level does not exceed the top of the basin It is recommended to keep at least a 2 clearance from the top of the basin Position the float so that it will operate freely and...

Страница 6: ...nd the AC adapter to the corre sponding terminals on the control panel Make sure they are fully seated in the terminals 4 Plug the AC adapter into the wall outlet and turn the power back on 5 If your...

Страница 7: ...ck up pump will automatically start The back up pump will operate for many hours intermittently During prolonged periods of power outage the pump may stop pumping when the battery voltage drops below...

Страница 8: ...at so it moves freely Battery is discharged below 10 volts Fully charge battery Pump cycles too often Float switch positioned improperly Reposition float switch Defective or missing check valve Instal...

Страница 9: ...p it will just reduce the output PERFORMANCES Performance ratings are based on using a 27M 12 volt deep cycle marine battery with a 100 Ah rating SPECIFICATIONS Motor 12 volt DC Amps 13 Battery Requir...

Страница 10: ...Intake Screen 99059 99059 9 Float Switch 92050 92055 10 Tethered Float Switch Clamp 99180 n a 11 Vertical Float Switch Bracket n a 99185 12 U Bolt Saddle Clamp Assembly 99462 99462 13 Battery Box Comp...

Страница 11: ...accident misapplica tion tampering alteration nor due to improper installation operation maintenance or storage nor to excess of recom mended maximums as set forth in the instructions Warranty will be...

Страница 12: ...12 2301 Traffic St N E Minneapolis MN 55413 1 800 495 9278 SUPERIOR BBU Manual Revised 2 12...

Отзывы: