TESTING YOUR INSTALLATION 

 
1.  Once  your  installation  and  wiring  connections  are  complete,  unplug  or  disconnect  the 

power to the primary pump. 

2.  Fill the basin using buckets or a hose.  Observe the float switches to make sure they are 

positioned properly when the basin is filling.  Fill the basin until the backup float activates 
the alarm.   

3.  Make any necessary adjustments to the float(s) and/or pumps at this time. 

 

 

OPERATION 

1.  When  the  power  fails  or  when  there  is  a  problem  with  the  primary  pump,  the  back-up 

pump  will  automatically  start.    The  back  up  pump  will  operate  for  many  hours 
intermittently.    During  prolonged  periods  of  power  outage  the  pump  may  stop  pumping 
when the battery voltage drops below 10 volts.  When this happens the alarm will sound 
signaling that the voltage is too low to operate the pump.   

2.  This unit is equipped with a 2 amp charger.  It will charge a discharged battery at a rate of 

2  Ah  (Amp  hours).    Once  the  battery  reaches  a  full  charge,  the  charger  will  gradually 
reduce the charge rate.  It will also maintain a charged battery by periodically checking the  
voltage of the battery.   

3.  The charger is equipped with over charge protection.  I will not let the battery become over 

charged.  

 

Содержание 92900

Страница 1: ...OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK UP SYSTEM Models 92900 92910...

Страница 2: ...ISK OF ELECTRICAL SHOCK Do not plug in or unplug the AC transformer while standing on a wet floor If basement floor is wet disconnect the power before walking on the floor WARNING Do not use the power...

Страница 3: ...cts can cause a carbon monoxide CO detector to give a false alarm When installing this system position the battery as far away from the CO detector as possible DO NOT move or remove CO detectors from...

Страница 4: ...tools and components of this system away from the work area when cutting pipe If any components get wet make sure they are dry before installing 7 If your primary pump does not have a check valve in o...

Страница 5: ...rimary pump Make sure the on level does not exceed the top of the basin It is recommended to keep at least a 2 clearance from the top of the basin Position the float so that it will operate freely and...

Страница 6: ...nd the AC adapter to the corre sponding terminals on the control panel Make sure they are fully seated in the terminals 4 Plug the AC adapter into the wall outlet and turn the power back on 5 If your...

Страница 7: ...ck up pump will automatically start The back up pump will operate for many hours intermittently During prolonged periods of power outage the pump may stop pumping when the battery voltage drops below...

Страница 8: ...at so it moves freely Battery is discharged below 10 volts Fully charge battery Pump cycles too often Float switch positioned improperly Reposition float switch Defective or missing check valve Instal...

Страница 9: ...p it will just reduce the output PERFORMANCES Performance ratings are based on using a 27M 12 volt deep cycle marine battery with a 100 Ah rating SPECIFICATIONS Motor 12 volt DC Amps 13 Battery Requir...

Страница 10: ...Intake Screen 99059 99059 9 Float Switch 92050 92055 10 Tethered Float Switch Clamp 99180 n a 11 Vertical Float Switch Bracket n a 99185 12 U Bolt Saddle Clamp Assembly 99462 99462 13 Battery Box Comp...

Страница 11: ...accident misapplica tion tampering alteration nor due to improper installation operation maintenance or storage nor to excess of recom mended maximums as set forth in the instructions Warranty will be...

Страница 12: ...12 2301 Traffic St N E Minneapolis MN 55413 1 800 495 9278 SUPERIOR BBU Manual Revised 2 12...

Отзывы: