Note: Ensure that the gas supply is isolated before commencing installation of the appliance.

The fireplace opening and environment must be in compliance with specifications laid down in the appropriate sections of these
instructions.

Remove the appliance from its carton as described previously and stand on a dustsheet.  Remove the hood and glass panel and
place safely to one side. Knock out holes are provided in the rear and sides of the firebox for use where concealed pipework is
required. Note: Knock out holes are also provided in the sides of the inner firebox if a side-entry pipe routing is required, but it
is essential to seal these holes with grommets.  Knock out the appropriate hole in the cavity box with a sharp tap from a ham-
mer and fit the rubber grommet  supplied.  A small incision can now be made in the rubber to slip snugly around the outside of
the supply pipe and sleeving. 

Warning :  Do not install or use the appliance without this seal in place.

Following preparation of the fixing method, the concealed gas supply (if required), can now be installed. 

When the opening is ready for installation the gas supply can be routed. If the gas pipe has been sleeved the ends of the sleeving
must be sealed. The end of the 8mm pipe should be temporarily sealed to prevent the ingress of debris during fixing. 
An inlet restrictor elbow is supplied as part of the appliance. All installation pipework must be in accordance with the current
edition of BS 6891,  and for timber framed dwellings, the current  edition of IGE/UP/7. In order to avoid unnecessary pressure
drops, no more than 1.5m of 8mm diameter pipe must be used.  If a concealed gas connection is to be made, the supply pipe
should always be sleeved through walls and floors using the shortest possible route. For concealed supply pipe routing, pipes must
(where possible) be vertical and providing there is sufficient wall thickness available, they should be placed in pipe chases.
Horizontal pipe runs should be avoided.  Prior to chasing a solid wall, an inspection should be made to note the proximity of any
cables/sockets outlets which may already be buried.  Pipes must be secured using suitable clips and protected against corrosion.
Ideally factory finished protected pipework and fittings should be used. Joints should be kept to a minimum and compression fit-
tings must not be used. The pipework installation must be tested for tightness before any protection is applied and/or the
pipework and fittings are buried. 

This method requires no modifications to the internal wall of a property and is achieved by using either a 
surround with extended rebate or a false chimney breast of minimum 105mm internal depth. If cable fixings are
to be used then the minimum depth should be 125mm.

A false chimney breast should be installed, taking into account any guidance given in the section on timber framed buildings as far
as insulation and clearances are concerned. When the false chimney breast is constructed from combustible materials the firebox
must be separated from any combustible materials by a minimum 75mm air gap at the sides and rear and 100mm air gap above
the firebox. Alternatively the firebox may be insulated with 75mm of fibre glass wool or rock wool to the sides, rear and 100 mm
to the top. 

©

2013 Superior Fires Ltd.

6.0 APPLIANCE 

INSTALLATION

GB IE

6.1 PREPARING THE APPLIANCE

6.2 GAS SUPPLY ROUTES

6.3 INSTALLATION METHOD 1 

(against a non-combustible inside wall)

Figure 5

False chimney breast

Non combustible back panel

Non combustible inside wall of building

Outer leaf of building

6

Содержание PI27 POSITANO LPG

Страница 1: ...G F500537 PI27 WESTBURY ELEGANCE BRASS BLK LPG F500539 PI27 WESTBURY ELEGANCE BLACK LPG F500541 PI27 POSITANO LPG F500422 INSET FLUELESS GAS FIRE Please note Except where otherwise stated all rights i...

Страница 2: ...background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning of...

Страница 3: ...ust not be separated by a door To calculate a room size in cubic metres m3 divide the room volume in cubic feet ft3 by 35 3 This appliance may be installed in any room in the home except bathrooms or...

Страница 4: ...ive facia In this situation the thickness of the hearth or ledge may be as desired but it must have the strength to support the weight of the appliance and the facia Clearances to non combustibles Non...

Страница 5: ...eat and moisture before proceeding with their installation If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to supp...

Страница 6: ...pipe should always be sleeved through walls and floors using the shortest possible route For concealed supply pipe routing pipes must where possible be vertical and providing there is sufficient wall...

Страница 7: ...rally under a block joint Clear out the block work in the area and insert the lintel by saw or stitch drill and chisel Do not dry bed the lin tel always bed on mortar and securely slate pin Clear out...

Страница 8: ...e with out excessive heat loss from the room when the fire is off Installation as per method 2 recessing into a wall When setting the appliance into the wall find a suitable position between frame tim...

Страница 9: ...opening and guide the gas pipe through the sealing grommet into its final routing position and fit the restrictor inlet elbow supplied to the gas pipe Secure the firebox by inserting screws in the pre...

Страница 10: ...tion 7 3 All models The gap between the spark electrode and the pilot should be 3 5 4 5mm to produce a good spark There should be no need to adjust this If under any circumstances the piezo electric s...

Страница 11: ...turning anti clock wise to the high position The main burner should light after a few seconds To decrease the setting to LOW push the knob in slightly and turn the control knob clockwise to the low s...

Страница 12: ...check operating pressures 17 Carry out combustion check as per section 9 4 Check safe operation of the appliance For specific servicing instructions see relevant sections Remove the fire front and pla...

Страница 13: ...bon monoxide CO concentration as displayed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carb...

Страница 14: ...here is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroug...

Страница 15: ...such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See relevant section for furth...

Страница 16: ...d such as metal heat deflec tors but it must be assured that the shelf does not reach an unacceptable temperature before relying on such a solution Under no circumstances should any electrical equipme...

Страница 17: ...monitoring safety device ODS If the fire shuts down during use for no apparent reason then several reasons may be suspected If a door or window has been opened creating a draught then pilot disturbanc...

Страница 18: ...are no other specific requirements for care other than regular cleaning of the general appliance A wipe with a dry cloth is normally sufficient GLASS PANEL This can be cleaned with a suitable glass c...

Страница 19: ...tor LPG Propane 0 80 F510089 Burner unit Natural Gas F510098 Burner unit LPG Propane F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 2013 Superior Fires Ltd 12 0 INSTALLA...

Отзывы: