2013 Superior Fires Ltd.

The sides and back of the appliance may be installed directly onto a non-combustible surfaces.
A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 200 mm from the top
of the appliance glass panel and the wall above the appliance is non combustible.  The shelf itself and any articles placed on it must
also be tolerant of high temperatures.

Clearances to combustible materials

Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any mate-
rial, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible mate-
rial or surface. Clearance to the sides of the appliance facia are 100mm (4”) but curtains, drapes and other fabrics are not per-
mitted within a distance of 500mm (20”) of the appliance sides. No such materials are permitted directly above the appliance
regardless of distance.  The minimum clearance to the ceiling above the appliance is 800mm (31.5”) measured from the top of the
appliance glass panel. Combustible materials should not be positioned directly in front of the appliance within a distance of one
metre. A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given below.
The shelf depth may be greater but the height must also be increased accordingly. An increase in height of 25 mm is required for
every 12.5 mm of additional shelf depth. For shelves that are too low protective devices can be used such as metal heat deflec-
tors, but it must be assured that the shelf does not reach an unacceptable temperature before relying on such a solution.  Under
no circumstances should any electrical equipment e.g. plasma screen TV sets etc. be positioned on the wall above the appliance.
Clearance to the sides and rear of the firebox are a 75mm (3“) air-gap. Clearance to the top of the firebox is a 100mm (4”) air-
gap. It should be established that any mirrors or picture frames etc. to be positioned on the wall above the appliance are able to
withstand prolonged exposure to moderate heat and moisture before proceeding with their installation. If the appliance is to be
mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to support the appli-
ance (e.g. so it can not be pulled from the wall) must be confirmed. It is important in these circumstances that any vapour con-
trol barrier is not damaged, and that any structural members of the house frame are not damaged - refer to section 6.5.

A minimum of 100 cm

2

purpose provided ventilation is required for this appliance. This may be achieved either with one vent 100

cm

2

at a high or low position in the room, or split ventilation i.e. 50cm

2

be installed at high level and 50cm

2

be installed at low

level within the room.  An openable window or equivalent is also required.
To reduce the possibility of draughts, road noise or insects entering the room via the air vent, we recommend the use of “Black
Hole”, “Vortex” or “Centurion” type vents featuring internal baffles. The requirements of any other gas, oil or solid fuel appliances
operating in the same room or space must be taken into consideration when assessing ventilation. 
Any ventilation fitted must comply with BS 5440 part 2. 
Ventilation fitted under, or within immediate vicinity of the appliance must not be used as it may adversely effect performance of
the ODS system. For Republic of Ireland refer to the current edition of IS813 and any relevant rules in force.  The appliance shall
not be installed within 1 metre of any existing air vent, and any new air vent shall not be installed within 1 metre of the appliance.

Lift off the remaining packaging components. Check that the components supplied correlate with the component checklist.  Please
dispose of all the packaging materials at your local recycling centre.

5.1 COMPONENT CHECKLIST

QUANTITY   

DESCRIPTION

1

Firebox and burner assembly

Set of manufacturer’s instructions

1

Contemporary Facia (Positano models)

Traditional One-Piece Frame (Westbury models)

1

Cast Firefront (Westbury models)

1

Coal Set (Front & Rear) (Westbury models)

1         

Rubber grommet

1

Cable fixing kit

1         

Screw pack including wall plugs

Positano screw pack consists of:

2         

No. 8 pozi self tapping screws

Westbury screw pack consists of:

2         

No. 8 pozi self tapping screws

4.0 SITE REQUIREMENTS - 

CONTINUED

GB IE

5.0 UNPACKING THE APPLIANCE

4.1 VENTILATION

5

Содержание PI27 POSITANO LPG

Страница 1: ...G F500537 PI27 WESTBURY ELEGANCE BRASS BLK LPG F500539 PI27 WESTBURY ELEGANCE BLACK LPG F500541 PI27 POSITANO LPG F500422 INSET FLUELESS GAS FIRE Please note Except where otherwise stated all rights i...

Страница 2: ...background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning of...

Страница 3: ...ust not be separated by a door To calculate a room size in cubic metres m3 divide the room volume in cubic feet ft3 by 35 3 This appliance may be installed in any room in the home except bathrooms or...

Страница 4: ...ive facia In this situation the thickness of the hearth or ledge may be as desired but it must have the strength to support the weight of the appliance and the facia Clearances to non combustibles Non...

Страница 5: ...eat and moisture before proceeding with their installation If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to supp...

Страница 6: ...pipe should always be sleeved through walls and floors using the shortest possible route For concealed supply pipe routing pipes must where possible be vertical and providing there is sufficient wall...

Страница 7: ...rally under a block joint Clear out the block work in the area and insert the lintel by saw or stitch drill and chisel Do not dry bed the lin tel always bed on mortar and securely slate pin Clear out...

Страница 8: ...e with out excessive heat loss from the room when the fire is off Installation as per method 2 recessing into a wall When setting the appliance into the wall find a suitable position between frame tim...

Страница 9: ...opening and guide the gas pipe through the sealing grommet into its final routing position and fit the restrictor inlet elbow supplied to the gas pipe Secure the firebox by inserting screws in the pre...

Страница 10: ...tion 7 3 All models The gap between the spark electrode and the pilot should be 3 5 4 5mm to produce a good spark There should be no need to adjust this If under any circumstances the piezo electric s...

Страница 11: ...turning anti clock wise to the high position The main burner should light after a few seconds To decrease the setting to LOW push the knob in slightly and turn the control knob clockwise to the low s...

Страница 12: ...check operating pressures 17 Carry out combustion check as per section 9 4 Check safe operation of the appliance For specific servicing instructions see relevant sections Remove the fire front and pla...

Страница 13: ...bon monoxide CO concentration as displayed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carb...

Страница 14: ...here is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroug...

Страница 15: ...such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See relevant section for furth...

Страница 16: ...d such as metal heat deflec tors but it must be assured that the shelf does not reach an unacceptable temperature before relying on such a solution Under no circumstances should any electrical equipme...

Страница 17: ...monitoring safety device ODS If the fire shuts down during use for no apparent reason then several reasons may be suspected If a door or window has been opened creating a draught then pilot disturbanc...

Страница 18: ...are no other specific requirements for care other than regular cleaning of the general appliance A wipe with a dry cloth is normally sufficient GLASS PANEL This can be cleaned with a suitable glass c...

Страница 19: ...tor LPG Propane 0 80 F510089 Burner unit Natural Gas F510098 Burner unit LPG Propane F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 2013 Superior Fires Ltd 12 0 INSTALLA...

Отзывы: