background image

SuperiorFireplaces.us.com

126700-01C

10

Figure 5 - Ventilation Air from Outdoors

Outlet

Air

Ventilated

Attic 

Outlet

Air

Inlet

Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation 

grills or ducts. You must provide two perma

-

nent openings: one within 12" of the ceiling 

and one within 12" of the floor. Connect these 

items directly to the outdoors or spaces open 

to the outdoors. These spaces include attics 

and crawl spaces. Follow the 

National Fuel 

Gas Code, ANSI Z223.1/NFPA 54, Air for 

Combustion and Ventilation

 for required size 

of ventilation grills or ducts.

IMPORTANT

:

 Do not provide openings 

for inlet or outlet air into attic if attic has a 

thermostat-controlled power vent. Heated air 

entering the attic will activate the power vent.

INSTALLATION

AIR FOR COMBUSTION AND VENTILATION

Continued

  WARNING: Never install 

firebox

•  in a bedroom or bathroom*

•  in a recreational vehicle

• where curtains, furniture, 

clothing, or other flammable 

objects are less than 36" 

from front or 42" from top of 

firebox; for side clearances 

see 

Figure 4, Page 11

•  in high traffic areas

•  in windy or drafty areas

* Unless installed log set is 

rated at 10,000 Btu/Hr or less. 

 

WARNING: A qualified ser

-

vice person must install firebox. 

Follow all local codes.

CAUTION: Log heaters in-

stalled in this firebox create 

warm air currents. These currents 

move heat to wall surfaces next 

to firebox. Installing firebox next 

to vinyl or cloth wall coverings or 

operating firebox where impuri

-

ties (such as, but not limited to, to-

bacco smoke, aromatic candles, 

cleaning fluids, oil or kerosene 

lamps, etc.) in the air exist, may 

discolor walls or cause odors.

IMPORTANT:

 Vent-free gas log heaters add 

moisture to the air. Although this is beneficial, 

installing  firebox  in  rooms  without  enough 

ventilation air may cause mildew to form from 

too much moisture. See, 

Page 8

.

IMPORTANT

:

 Make sure the firebox is level. 

If  firebox  is  not  level,  log  set  will  not  work 

properly.

NOTE

: Your firebox is designed to be used in 

zero clearance installations. Wall or framing 

material can be placed against any exterior 

surface on the rear, sides, top or bottom of 

your firebox, except where standoff spacers 

are integrally attached. If standoff spacers are 

attached to your firebox, these spacers can 

be placed directly against wall or framing ma

-

terials. Use the dimensions shown for rough 

opening to create the easiest installation.

Use  dimensions  shown  for  rough  openings 

to create the easiest installation (see 

Built-In 

Firebox Installation

Page 12

).

NOTICE: The firebox identifica

-

tion label (including model num-

ber, serial number, clearances, 

etc.) is located on a chain under 

the bottom refractory.

Содержание VRT4536WH

Страница 1: ...ury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appli...

Страница 2: ...ANSI Z21 11 2 decorative type un vented room heater WARNING Anychangetothisfire box or its controls can be dangerous DANGER Carbon monoxide poi soning may lead to death WARNING Do not use a blower ins...

Страница 3: ...te clearances around air openings 11 Use only the provided hood See Parts Page 19 Due to high temperatures the ap pliance should be located out of traffic and away from furniture and draperies Do not...

Страница 4: ...Fuel Gas Code ANSI Z223 1 NFPA 54 National Fuel Gas Code latest edition Firebox must be electrically grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition COMMONWEALTH...

Страница 5: ...T SPECIFICATIONS 36 MODELS Figure 1 36 Models VRT4536WS and VRT4536WH Picture may vary from actual fireplace 30 1 2 29 30 11 1 8 54 3 4 7 7 8 7 36 45 1 4 33 8 91 2 50 1 8 363 8 7 3 8 111 8 3 3 4 4 7 8...

Страница 6: ...FICATIONS Continued 42 MODELS Figure 2 42 Models VRT4542WS and VRT4542WH Picture may vary from actual fireplace 4 7 8 54 3 4 7 7 8 7 36 3 8 50 1 8 42 51 1 4 32 3 8 3 3 4 30 3 8 8 3 4 13 3 3 8 9 1 2 30...

Страница 7: ...CIFICATIONS Continued 50 MODELS Figure 3 50 Models VRT4550WS and VRT4550WH Picture may vary from actual fireplace 363 8 50 1 8 8 3 4 13 33 8 91 2 59 1 4 50 7 7 8 7 30 54 3 4 11 1 8 32 3 8 3 3 4 38 3 8...

Страница 8: ...termine if the space is confined or unconfined Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them DETERMINING FRESH AIR FLOW FOR HEATER LOCATIO...

Страница 9: ...u Hr the space can support with the actual amount of Btu Hr used ________ Btu Hr maximum the space can support ________ Btu Hr actual amount of Btu Hr used Example 63 360 Btu Hr maximum the space can...

Страница 10: ...d ser vice person must install firebox Follow all local codes CAUTION Log heaters in stalled in this firebox create warmaircurrents Thesecurrents move heat to wall surfaces next to firebox Installing...

Страница 11: ...eplace cabinet see Figure 4 B Clearances from the top of the firebox opening to the ceiling should not be less than 42 C When firebox is installed on carpeting tile other than ceramic or other combust...

Страница 12: ...s in Figure 9 for rough opening 2 Install gas piping to firebox location See Gas Line Installation on Page 16 and Con necting to Gas Supply in log set owner s manual WARNING Do not allow any combustib...

Страница 13: ...t mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be avail able from your retailer or custom built for your home 1 Assemble cabinet...

Страница 14: ...NEL PANEL RIGHT BRICK REAR BRICK PANEL BOTTOM BRICK PANEL ASH PANEL UPPER CORNER BRACKET 2x 3 Install rear refractory panel This panel has a top and bottom To determine which is which match up the pat...

Страница 15: ...of fireplace and pull out insula tion from gas line conduit sleeve Save insulation for reuse Replace screws 3 Run a 1 2 black iron gas line into fireplace through the rear at gas line conduit sleeve...

Страница 16: ...If you wish to install an unvented vent free gas log set only unvented gas log sets which have been found to comply with the standard for unvented room heaters ANSI Z21 11 2 are to be installed in thi...

Страница 17: ...Outside Air Kit Collar Hood 3 Flex for Floor Venting Cat No F1094 Model AK4B 50 piece Bulk Outside Air Kit Collar Only Kit OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION Cat No F1091 Model AK4 4 A...

Страница 18: ...10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 Cat No Model Interior F0277 VRT4536WS White Stack F0278 VRT4536WH White Herr F0279 VRT4542WS White Stack F0280 VRT4542...

Страница 19: ...irebox Top 1 20 J4342 Screen 36 2 J4341 Screen 42 2 J4340 Screen 50 2 F3235 Screen 36 Stainless 2 F3236 Screen 42 Stainless 2 F3237 Screen 50 Stainless 2 21 J6928 Screen Rod 36 2 J4391 Screen Rod 42 2...

Страница 20: ...vary from actual 1 2 5 3 4 6 6 1 2 3 4 5 6 7 7 WARNING REFRACTORY PANELS LIFTING HAZARD SINGLE PERSON LIFT COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING IMPORTANT Installation of refractor...

Страница 21: ...tural White 1 Right Stacked 42 Natural White 1 Right Herringbone 42 Natural White 1 Right Stacked 50 Natural White 1 Right Herringbone 50 Natural White 1 4 Left Stacked 36 Natural White 1 Left Herring...

Страница 22: ..._________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 23: ...ural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c d...

Страница 24: ...istributor for fireplace code information Printed in U S A 2021 Innovative Hearth Products P N 126700 01 Rev C 06 2021 1769 East Lawrence Street Russellville AL 35654 SuperiorFireplaces us com Record...

Отзывы: