![Superior Fireplaces VRE3236ZENWH Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/superior-fireplaces/vre3236zenwh/vre3236zenwh_installation-instructions-manual_1403181009.webp)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9
Figure
8
Figure
11
FRAMING SPECIFICATIONS
Figure
9
Figure
10
Header
A
B*
* Increase Framing Height By 3/4”
When Using Optional Drain Pan
Corner Installation
A
C
D
H
F
G
E
Back Wall Of
Chase/Enclosure
Including Finishing
Materials If Any
Rough Framing Face
(Unfinished Shown)
C
G
A
Parallel Installation
Rough Framing Face
(Unfinished Shown)
Back Wall Of
Chase/Enclosure
Including Finished
Materials - If Any
*Increase Framing Height by 34" when using an Optional Drain Pan
inches (millimeters)
12
(305)
10
(254)
8
(203)
6
(152)
4
(102)
2
(51)
9 (229)
13 (330)
11 (280)
15 (381)
13 (330)
17 (432)
15 (381)
19 (483)
17 (432)
21 (534)
19 (483)
23 (585)
Hood
Fireplace
Fireplace
Mantel depth
Mantel depth
WITHOUT
HOOD
INSTALLED
WITH
HOOD
INSTALLED
Top of Firebox
Opening
12
(305)
10
(254)
8
(203)
6
(152)
4
(102)
2
(51)
Mantel Clearances
Opening
VRE3236
VRE3242
A
42-3/4" (1086)
48-3/4" (1238)
B
46-1/2" (1181)
46-1/2" (1181)
C
23-5/8" (600)
29-5/8" (753)
D
11-1/4" (286)
14-1/4" (362)
E
63-1/2" (1613)
69-1/2" (1765)
F
31-3/4" (807)
34-3/4" (883)
G
20-1/2"( 521)
20-1/2"( 521)
H
44-1/4" (1124)
49-1/8" (1248)
Table 5 - This Table Corresponds To Figures 8, 9 and 10