INSTALLATION

Continued

Figure 11 - Location of Knockout for 

Gas Line

Knockout

Chisel

Firebrick Side Wall

Remove 
this Area 

Side 
View

Figure 10 - Installing Gas Line and 

Equipment Shutoff Valve (Model May 

Vary From Illustration)

Knockout 
Locations 
(Knock Out 
One Hole)

Gas Line Hole

Equipment Shutoff 
Valves (Install One) 

No Hearth

NOTICE: A qualifi ed service per-
son must connect heater to gas 
supply. Follow all local codes.

Notice: The fi rebox identifi cation 
label (including model number, 
serial number, clearances, etc.) 
is located in the right side screen 
pocket area on the front of the 
fi rebox. See Figures 23 and 24, 
Page 20.

Notice: If a log set is installed in 
the fi rebox, disconnect log set 
from gas supply and remove 
from fi rebox. Contact a qualifi ed 
service person to do this.

 CAUTION: Do not use exces-

sive force to remove the knock-
out. Too much force may damage 
the fi rebrick concrete insert.

INSTALLING GAS LINE

IMPORTANT:

 See 

Connecting to Gas Supply

 

in your log set owner’s manual for details on 
gas hookup.
You may run the gas line from either side of 
the fi rebox 

(see Figure 10, Page 13)

. Decide 

which side you want to run the gas line from. 

NOTE: This is one option for installing shutoff 
valve. Check local codes for equipment shut-
off valve location requirements.

Locate the recessed knockout in one of the 
fi rebrick sidewall liners 

(see  Figure 10 on 

Page 13 and Figure 11)

. Firmly tap the center 

of the knockout with a chisel until it is released. 
Carefully chisel the rough edges of the hole 
you have made to smooth edges. This hole 
will line up with the hole in the outer casing.

INSTALLING OPTIONAL BLOWER 
ACCESSORIES

NOTE: Appearance of fi rebox may vary de-
pending on model.

There are two (2) blower accessory options for 
use in this fi replace. Blower accessory models 
are BK available on all units and BK3 available 
for VCT36 and VCT42 series. Model BK is a 
rotary squirrel cage type blower with magnetic 
attachment and variable speed control. The 
BK3 is a triple fan blower system with an on/
off rocker switch.

Wiring Instructions

1. 

Remove electrical cover plate with bush-
ing from fi replace by removing 2 sheet 
metal screws as shown in 

Figure 12

.

Содержание VCT3032B

Страница 1: ...EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of...

Страница 2: ...NG Do not allow fans to blow directly into the firebox Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cau...

Страница 3: ...rebox if it has been un der water due to the shock hazard that could result with the blower accessary if installed in place Firebox front and screen be comes very hot when running firebox Keepchildren...

Страница 4: ...install the firebox Before installation consider the following 1 Where the firebox will be located Allow for wall and ceiling clearances see Installa tion Clearances Page 11 2 Everything needed to com...

Страница 5: ...3 3 8 3 5 8 8 1 4 29 3 8 36 5 8 2 5 8 7 7 6 1 8 16 5 8 4 3 8 10 5 8 13 1 8 10 1 2 3 5 8 8 1 4 6 7 8 6 7 8 8 1 4 PRODUCT SPECIFICATIONS Figure 1 Product Specifications 32 Models Right Side View Left S...

Страница 6: ...21 1 8 21 43 1 8 41 1 8 35 7 1 8 36 1 8 8 1 8 26 3 8 8 1 4 8 1 4 8 3 8 10 3 8 14 8 5 8 8 5 8 7 1 2 2 5 8 11 1 2 3 3 8 40 1 4 Right Side View Left Side View Front View Firebox Top View 36 MODELS Figur...

Страница 7: ...0 1 4 2 5 8 8 1 4 10 3 4 10 1 2 12 5 8 14 1 4 7 1 8 42 40 1 8 42 6 1 8 23 1 4 4 1 2 36 1 4 40 1 8 24 44 1 4 3 3 8 13 3 8 8 1 4 2 5 8 10 5 8 7 5 8 42 MODELS Figure 3 Product Specifications 42 Models Ri...

Страница 8: ...he National Fuel Gas Code ANSI Z223 1 NFPA 54 to use this method to determine if the space is confined or unconfined Adjoining rooms are communicating only if there are doorless passageways or ventila...

Страница 9: ...ces Direct vent draws combustion air from the outdoors and vents to the outdoors Example Gas water heater _________ Btu Hr Vent free fireplace _________ Btu Hr Total _________ Btu Hr 4 Compare the max...

Страница 10: ...for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will...

Страница 11: ...e installation Use larger clearances wherever possible to minimize the heating of objects and materials placed on the mantel Figure 6 Minimum Clearance for Combustible to wall WARNING Maintain the min...

Страница 12: ...de to Inside Height Figure 8a Figure 8b Figure 8c Figure 8d BUILT IN FIREBOX INSTALLATION Built in installation of this firebox involves installing firebox into a framed in enclosure This makes the fr...

Страница 13: ...firebox front facing INSTALLATION Continued Figure 9 Attaching Firebox to Wall Studs Model May Vary From Illustration WARNING DO NOT FILL THE SPACES AROUND THE FIREBOXWITHINSULATIONOR OTHER MATERIALS...

Страница 14: ...t owner s manual for details on gas hookup You may run the gas line from either side of the firebox see Figure 10 Page 13 Decide which side you want to run the gas line from NOTE This is one option fo...

Страница 15: ...s Accessibility to the bottom on 36 and 42 models only can also be gained through the access panel underneath the bottom front refractory brick liner Lift the bottom front refractory brick liner up an...

Страница 16: ...ay be sharp 4 Place control knob provided onto control shaft see Figure 17 5 Check to make sure power cord is com pletely clear of blower wheel and there are no foreign objects in blower wheel Also do...

Страница 17: ...power cord to duplex outlet see Figure 14 Page 15 8 Turn blower on and check for operation Turn blower off by turning knob fully coun terclockwise before continuing 9 Peel off backing paper and stick...

Страница 18: ...e 14 Page 15 7 Using ON OFF rocker switch to turn blower on and check for operation Turn blower off before continuing 8 Peel off backing paper and stick supplied wiring diagram decal on firebox bottom...

Страница 19: ...ir is accessed through a vented crawl space AK4F or through a sidewall AK4 See Figure 21 Figure 21 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet...

Страница 20: ...right side of firebox and fasten using remaining Phillips screw LOCATING ACCESS COVER PLATE Sheet metal cover plates located underneath front hearth refractory if included may have shifted or moved ou...

Страница 21: ...liance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any q...

Страница 22: ...Brushed Brass Cat No F1049 Model H36P 36 Platinum Cat No F1050 Model H42B 42 Brushed Brass Cat No F1051 Model H42P 42 Platinum ACCESSORIES Continued MANTELS 32 WALL MANTELS Cat No F1140 Model W32TU 3...

Страница 23: ...el SL36 36 Model Cat No J2320 Model SL42 42 Model Rolled Black Cat No J2271 Model RL32 32 Model Cat No J2272 Model RL36 36 Model Cat No J2273 Model RL42 42 Model Filigree Black Cat No J0966 Model FP32...

Страница 24: ...ed White Stack F0302 VRT3032B Radiant Black F0308 VRT3032WS Radiant White Stack F0305 VCT3036B Louvered Black F0311 VCT3036WS Louvered White Stack F0304 VRT3036B Radiant Black F0310 VRT3036WS Radiant...

Страница 25: ...Screen 2 2 K2001 Screen Rod 2 J3975 Screen Rod 2 J4084 Screen Rod 2 3 J4956 Push On Nut 2 4 J4183 Hood Deflector 1 J4090 Hood Deflector 1 J4092 Hood Deflector 1 5 J6918 Spacer Top 4 6 J6934 Cover Gas...

Страница 26: ...VCT3032WS VRT3036WS VCT3036WS VRT3042WS AND VCT3042WS IMPORTANT Installation of brick panels should be done after the fireplace is placed in a permanent location WARNING LIFTING HAZARD SINGLE PERSON L...

Страница 27: ...te Stack Refractory Set 42 2 Left Refractory White Stack 32 1 Left Refractory White Stack 36 1 Left Refractory White Stack 42 1 3 Right Refractory White Stack 32 1 Right Refractory White Stack 36 1 Ri...

Страница 28: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 29: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...ural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c dam...

Страница 32: ...istributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126712 01 Rev C 01 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 SuperiorFireplaces US com Record...

Отзывы: