SuperiorFireplaces.US.com
126712-01C
14
INSTALLATION
Continued
Figure 11 - Location of Knockout for
Gas Line
Knockout
Chisel
Firebrick Side Wall
Remove
this Area
Side
View
Figure 10 - Installing Gas Line and
Equipment Shutoff Valve (Model May
Vary From Illustration)
Knockout
Locations
(Knock Out
One Hole)
Gas Line Hole
Equipment Shutoff
Valves (Install One)
No Hearth
NOTICE: A qualifi ed service per-
son must connect heater to gas
supply. Follow all local codes.
Notice: The fi rebox identifi cation
label (including model number,
serial number, clearances, etc.)
is located in the right side screen
pocket area on the front of the
fi rebox. See Figures 23 and 24,
Page 20.
Notice: If a log set is installed in
the fi rebox, disconnect log set
from gas supply and remove
from fi rebox. Contact a qualifi ed
service person to do this.
CAUTION: Do not use exces-
sive force to remove the knock-
out. Too much force may damage
the fi rebrick concrete insert.
INSTALLING GAS LINE
IMPORTANT:
See
Connecting to Gas Supply
in your log set owner’s manual for details on
gas hookup.
You may run the gas line from either side of
the fi rebox
(see Figure 10, Page 13)
. Decide
which side you want to run the gas line from.
NOTE: This is one option for installing shutoff
valve. Check local codes for equipment shut-
off valve location requirements.
Locate the recessed knockout in one of the
fi rebrick sidewall liners
(see Figure 10 on
Page 13 and Figure 11)
. Firmly tap the center
of the knockout with a chisel until it is released.
Carefully chisel the rough edges of the hole
you have made to smooth edges. This hole
will line up with the hole in the outer casing.
INSTALLING OPTIONAL BLOWER
ACCESSORIES
NOTE: Appearance of fi rebox may vary de-
pending on model.
There are two (2) blower accessory options for
use in this fi replace. Blower accessory models
are BK available on all units and BK3 available
for VCT36 and VCT42 series. Model BK is a
rotary squirrel cage type blower with magnetic
attachment and variable speed control. The
BK3 is a triple fan blower system with an on/
off rocker switch.
Wiring Instructions
1.
Remove electrical cover plate with bush-
ing from fi replace by removing 2 sheet
metal screws as shown in
Figure 12
.