background image

SuperiorFireplaces.us.com

126871-01B

4

SAFETY 

Continued

2.  Do not place propane/LP supply tank(s) 

inside  any  structure.  Locate  propane/
LP supply tank(s) outdoors (propane/LP 
only).

3.  If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-
plier’s instructions 

• if  you  cannot  reach  your  gas  supplier, 

call the fi re department

4.  This  fi replace  shall  not  be  installed  in  a 

bedroom or bathroom.

5.  Do not use this fi replace as a wood-burn-

ing fi replace. Use only the logs provided 
with the fi replace. 

6.  Do not add extra logs or ornaments such 

as pine cones, vermiculite, or glowing em-
bers (rockwool). Using these added items 
can cause sooting. Do not add volcanic 
stone  around  base.  Volcanic  Stone  and 
debris  could  fall  into  the  control  area  of 
fi replace.

7.  This fi replace is designed to be smoke-

less. If logs ever appear to smoke, turn 
off  fi replace  and  call  a  qualifi ed  service 
person. 

 

NOTE

:  During  initial  operation,  slight 

smoking could occur due to log curing and 
fi replace burning manufacturing residues. 

8.  To prevent the creation of soot, follow the 

instructions in 

Cleaning and Maintenance

Page 25

.

9.  Before using furniture polish, wax, carpet 

cleaner,  or  similar  products,  turn  heater 
off. If heated, the vapors from these prod-
ucts may create a white powder residue 
within burner box or on adjacent walls or 
furniture.

10. This fi replace needs fresh air ventilation to 

run properly. This fi replace has an Oxygen 
Depletion  Sensing  (ODS)  safety  shutoff 
system.  The  ODS  shuts  down  the  fi re-
place if not enough fresh air is available. 
See 

Air for Combustion and Ventilation

Page 7

. If fi replace keeps shutting off, see 

Troubleshooting

Page 26

.

11. Do not run fi replace

• where  fl ammable  liquids  or  vapors  are 

used or stored.

• under dusty conditions.

12. Do not use this fi replace to cook food or 

burn paper or other objects.

13. Never place any objects in the fi replace 

or on logs.

14. Do not use fi replace if any part has been 

under water. Immediately call a qualifi ed 
service  technician  to  inspect  the  room 
fi replace  and  to  replace  any  part  of  the 
control system and any gas control which 
has been under water. 

15. Turn  off  and  unplug  fireplace  and  let 

cool  before  servicing.  Only  a  qualifi ed 
service person should service and repair 
fi replace.

16. Operating  fi replace  above  elevations  of 

4,500 feet could cause pilot outage.

17. Do  not  operate  fireplace  if  any  log  is 

broken. Do not operate fi replace if a log 
is chipped (dime-sized or larger).

18. To prevent performance problems, do not 

use propane/LP fuel tank of less than 100 
lbs. capacity (propane/LP only). 

19. Provide adequate clearances around air 

openings.

20. The screen or any other part removed for 

servicing must be replaced prior to operat-
ing this heater.

1.  WARNING: This appliance is only for 

use with the type of gas indicated on 
the rating plate. This appliance is not 
convertible for use with other gases. 

All manuals and user guides at all-guides.com

Содержание VCM3026ZTN

Страница 1: ...vided Refer to Air for Combustion and Ventilation section on Page 7 of this manual PFS US Report No F09 123 WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in s...

Страница 2: ...your guide to safe and proper operation of this heater WARNING FIRE EXPLOSION AND ASPHYXIATION HAZARD Improperadjustment alteration service maintenance orinstallationofthis heater or its controls can...

Страница 3: ...topreventchildrenfromturning on burners with remote Youmustoperatethisheaterwiththe replace screen and hood in place before running heater The replace screenshallhaveopeningsforintro duction of combus...

Страница 4: ...ue within burner box or on adjacent walls or furniture 10 This replace needs fresh air ventilation to run properly This replace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts...

Страница 5: ...appliances may NOT be installed in bedrooms or bathrooms A working smoke detector must be installed in the area where vent free appliances are installed Seller of unvented propane or natural gas red...

Страница 6: ...hood as shown in Figure 3 Make sure hood tabs point toward replace 3 Insert hood tabs between baf e and lou vers see Figure 3 Figure 3 Assembling Hood Hood Louver Hood Tab Baf e Sheet Metal Screw Fir...

Страница 7: ...etween sole plates and oors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home meets all of the three criteria abo...

Страница 8: ...mbustion air from the outdoors and vents to the outdoors Example Gas water appliance __________ Btu Hr Gas rebox logs _________ Btu Hr Total _________ Btu Hr 4 Compare the maximum Btu Hr the space can...

Страница 9: ...openings one within 12 of the ceiling and one within 12 of the oor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the N...

Страница 10: ...o propane LP gas equipment shutoff valve test gauge connection ground joint union sediment trap tee joint pipe wrench A shutoff valve with 1 8 NPT tap is an ac ceptable alternative to test gauge conne...

Страница 11: ...aterial 0 Minimum To Top Surface Of Carpeting Tile Or Other Combustible Material Figure 6 Mounting Clearances As Viewed From Front of Fireplace Shown Built In the Wall NOTE When installing replace dir...

Страница 12: ...with pliers see Figure 10 8 Attach replace to wall studs using nails or wood screws through holes in nailing ange 9 Check all gas connections for leaks See Checking Gas Connections Page 20 10 If usin...

Страница 13: ...alling in Wall Figure 10 Attaching Fireplace to Wall Studs Nails or Wood Screws Nailing Flanges WARNING Do not allow any com bustible noncombustible materials to overlap the firebox front facing WARNI...

Страница 14: ...see mantel instruction sheet 7 Attach exible gas line to replace gas regulator See Connecting to Gas Supply Page 18 8 Route electrical cord s through access holes in either side of replace with bushi...

Страница 15: ...uver Assembly Black Screws Blower Bracket Mounting Holes Figure 13 Installing Fireplace into Mantel Assembly 5 Slide other end of adjusting plate shim in slot on mitered edge of side trim see Figure 1...

Страница 16: ...fan kit into 120 Volt grounded power supply and test operation Installing Blower Assembly CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors cancauseimproperanddanger o...

Страница 17: ...the wir ing diagram to connect incoming electri cal supply to fan kit wiring harness see Figure 19 5 Plug power cord to the outlet receptacle not provided as shown in Figure 18 Wind the extra power c...

Страница 18: ...e of 1 2 or greater diameter to allow proper gas volume to replace If pipe is too small undue loss of volume will occur Propane LP Supply Tank External Regulator Figure 21 External Regulator with Vent...

Страница 19: ...ort Screen Screen Shipping Screw Shoulder Screw Flexible Gas Line CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL Installation Items Needed Phillips screwdriver sealant resistant to propane LP ga...

Страница 20: ...SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply piping Pressures in excess of 1...

Страница 21: ...actly a re or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions...

Страница 22: ...en in place Make sure re place screen is installed before running replace NOTICE Duringinitialoperation of new replace burning logs will give off a paper burning smell Orange ame will also be present...

Страница 23: ...on location room size open air temperatures etc Frequent use of your replace will let you determine your own comfort levels MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Lighting Instruct...

Страница 24: ...liance Page 23 see Troubleshooting Page 26 Figure 33 Correct Burner Flame Pattern Figure 34 Incorrect Burner Flame Pattern INSPECTING BURNER Check pilot ame pattern and burner ame pattern often PILOT...

Страница 25: ...reas of replace before each use Have replace inspected yearly by a quali ed service person Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc...

Страница 26: ...in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Free igniter cable if pinched by any metal or tubing Keep igniter cable dry 2 R...

Страница 27: ...t Repeat ignition operation 4 Fully open equipment shut off valve 5 Hand tighten until snug then tighten 1 4 turn more 6 A Contact local propane LP or natural gas company B Clean ODS pilot see Cleanin...

Страница 28: ...minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP gas company 3 Observe minimum installa tion clearances see Pages 10 through 14 4 Clean burner see Clean...

Страница 29: ...k See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ventilation air REMEDY 1 Ventil...

Страница 30: ...l gas supplier TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your deale...

Страница 31: ...Page of this manual Only kits supplied by IHP shall be used in the in stallation of this appliance Use of non approved accessory part kit s can result in poor perfor mance and safety hazards ACCESSORI...

Страница 32: ...25 27 20 4 35 12 24 12 1 14 25 14 40 3 37 26 39 39 5 6 Cat No Model Description F1215 VCM3026ZTN 26 T Stat NG F1216 VCM3026ZTP 26 T Stat LP WARNING Contact an IHP dealer to obtain any of these parts N...

Страница 33: ...nch Support 1 21 J3647 Gas Regulator 1 J3648 Gas Regulator 1 22 J3779 Regulator Bracket 1 23 J3714 Valve Cover and Piezo 1 24 J3635 Pilot Tube 1 25 J3567 Igniter Cable 1 26 J4013 Injector 0 059 1 J401...

Страница 34: ...________________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________...

Страница 35: ...y Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failin...

Страница 36: ...tion Printed in U S A 2014 Innovative Hearth Products P N 126871 01 Rev B 04 2018 SuperiorFireplaces us com Record the following important information about your appliance Appliance model number Appli...

Отзывы: