OPERATION

Continued

Figure 36 - Setting the Selector Switch, Control 

Knob, and Flame Adjustment Knob for Hand-

Held Remote Operation

O

FF

   

PI

LO

T

  

 

LO

 

IH

 

REMOTE
OFF
ON

ON

         

   

   

 

Flame Adjustment 
Knob

Control Knob

Selector Switch in REMOTE Position 
(Optional Hand-Held Remote Control)

GWMT1 WALL MOUNTED 

THERMOSTAT (OPTIONAL)

GWMS2 WALL MOUNTED

SWITCH (OPTIONAL)

OPERATING

BLOWER (OPTIONAL)

Make  sure  heater  switch  is  on  AUTO  and  set 
temperature  adjustment  on  wall  thermostat  to 
desired setting. Thermostat has been electronically 
calibrated at the factory and requires no adjustment 
or leveling.
Upon  installation,  thermostat  must  be  allowed  to 
stabilize  at  room  temperature  for  a  minimum  of 
30  minutes  for  proper  operation.  See  installation 
instructions on 

Page 21

 of this manual.

Make sure heater switch is on AUTO. This wall switch 
works  just  like  the  conventional  light  switch.  Flip 
switch up for on and down for off.

NOTE

: Make sure that this switch is not in a position 

to be mistaken for a light switch. This may result 
in fi replace being inadvertently turned on without 
proper  precautions  being  taken.  See  installation 
instructions on 

Page 22 

of this manual.

This blower has three settings: ON, OFF, and AUTO. 
In ON position, blower will operate constantly. In 
OFF  position,  blower  will  not  operate.  In  AUTO 
position, blower will start when thermostat senses 
a suffi cient increase in fi rebox temperature.

NOTE

:  Your  fi replace  and  thermostat  blower  will 

not  turn  on  and  off  at  the  same  time.  Fireplace 
may run for several minutes before blower turns 
on. After heater modulates to pilot position, blower 
will continue to run. The blower will shut off after 
fi rebox temperature decreases.

MANUAL LIGHTING

PROCEDURE

3.  To shut off burners only and keep pilot lit, you 

can  turn  control  knob  clockwise 

  to 

PILOT position, use remote control manual OFF 
button, or set selector switch in OFF position.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit 
by doing one of the following:
1.  Turn  control  knob  clockwise 

  to  the 

PILOT position.

2.  Use remote control manual OFF button.
3.  Set selector switch in the OFF posi

tion.

1.  Follow  steps  1  through  6  under 

Lighting  In-

structions

,

 Page 23

.

2.  Depress control knob and light pilot with match.
3.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 
control knob. Now follow steps 9 through 11, 

Lighting Instructions

Page 23

.

OPTIONAL HAND-HELD

REMOTE OPERATION

NOTE

: All remote control accessories must be pur-

chased separately (see Accessories, 

Page 34

). Fol-

low instructions included with the remote control.

NOTICE:  You  must  light  the  pilot 
before  using  the  hand-held  remote 
control unit. See 

Lighting Instructions

 

on 

Page 23

.

After  lighting,  let  pilot  fl ame  burn  for  about  one 
minute. Turn control knob to ON position. Adjust 
fl ame adjustment knob anywhere between HI and 
LO. Slide the selector switch to the REMOTE posi-
tion 

(see 

Figure 36

). 

NOTE

:  The  burner  may  light  if  hand-held  remote 

was on when selector switch was last turned off. 
You can now turn the burner on and off with the 
hand-held remote control unit.

 

IMPORTANT

: Do not leave selector switch in RE-

MOTE or ON position when pilot is not lit. This will 
drain the battery.

Содержание VCM3026ZMN

Страница 1: ...ch it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 7 of this manual WARNING If the information in th...

Страница 2: ...Safety Standards and are listed by PFS TECO to ANSI Z21 11 2 as unvented Gas fired room heaters This appliance may be installed in an aftermarket permanently located manufactured mobile home where not...

Страница 3: ...rial other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Fireplace front and screen become very hot when running fire...

Страница 4: ...create a white powder residue within burner box or on adjacent walls or furniture 10 This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safe...

Страница 5: ...the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 inches 92 centimeters in length The individual manual shut off must be a T handle type valve Unvented applian...

Страница 6: ...til installation has been completed 2 Cut two plastic straps to remove the log from the firebox cavity 3 Anoptionalblowerisavailable SeeAccessories Page 34 Install optional blower now Follow installat...

Страница 7: ...ound window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home meet...

Страница 8: ...ct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors Example Gas water appliance ____________ Btu Hr Gas firebox logs ___________ Btu Hr Total __________...

Страница 9: ...ion grills or ducts You must provide two permanent open ings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors The...

Страница 10: ...e in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation Page 7 NOTE Your fireplace is designed to be used in zero clearanceinst...

Страница 11: ...8 Page 12 for the rough opening The height is 26 7 8 which is the same as the wall opening above 2 If installing GA3450TA blower accessory do so at this time Follow instructions included with blower a...

Страница 12: ...ible materials such as wall board gypsum board sheet rock drywall plywood etc may be butted up next to the sides and top edge of the firebox Combustible materials should never overlap the firebox fron...

Страница 13: ...hearth base to run gas line to fireplace see Figure 11 Make sure to locate access hole so cabinet mantel will cover it when installed NOTE You can secure base to floor using wood screws Countersinksc...

Страница 14: ...lign fireplace in mantel assembly so the trim overlaps mantel evenly on all three sides 12 Lower bottom louver door Use 3 wood screws provided with mantel accessory to attach fire place to base see ma...

Страница 15: ...rd out of the cabinet by inserting it through the bushing on the outer casing see Figure 16 Page 16 Plug fan kit into 120 Volt grounded power supply and test operation NOTE When switch is in the AUTO...

Страница 16: ...ff On Blue Blue Thermostat Switch N O Green White Green White On 110 115 V A C Blower Motor Black Off 1 2 3 Auto Figure 18 Installing Switch Plate to Valve Cover Shield Valve Cover Shield Switch Plate...

Страница 17: ...e 19 4 Plug power cord to the outlet receptacle not provided as shown in Figure 20 Wind the extra power cord and tie with plastic wire strap see Figure 20 Set the power cord bundle between the burner...

Страница 18: ...O GAS SUPPLY WARNING Thisappliancerequiresa 45 maleflarefitting5 8 18UNF Unified National Fine Thread inlet connection and the flexible gas line provided WARNING A qualified service person must connec...

Страница 19: ...e controls If sediment trap is not installed or is installed wrong fireplace may not run properly Figure 24 Attaching Flexible Gas Line to Equipment Shutoff Valve Flexible Gas Line from Fireplace Gas...

Страница 20: ...all leaks at once CAUTION Make sure external regulator has been installed between propane LPsupplyandappliance See guidelines under Connecting to Gas Supply Page 18 CHECKING GAS CONNECTIONS Test Press...

Страница 21: ...ed Wire 3 Route 25 ft wire to a convenient location to mount your thermostat no outside wall IM PORTANT Wire may be shortened but must not be lengthened Thermostat should be mounted 54 above the floor...

Страница 22: ...n should be done by a qualified installer familiar with low voltage wiring procedures WARNING Do not connect the switch to a power source Electrical shock and or fire hazard will occur WARNING Do not...

Страница 23: ...supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the applia...

Страница 24: ...pilot with match To light pilot with match see Manual Lighting Procedure Page 25 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If control kno...

Страница 25: ...may run for several minutes before blower turns on After heater modulates to pilot position blower will continue to run The blower will shut off after firebox temperature decreases MANUAL LIGHTING PRO...

Страница 26: ...have a slight curve but flame should be blue and have no yellow or orange color Figure 38 Correct Pilot Flame Pattern Propane LP Shown Pilot Burner Thermocouple Figure 39 Incorrect Pilot Flame Pattern...

Страница 27: ...yearly by a qualified serviceperson Heatermayneedmore frequentcleaningduetoexcessivelint from carpeting bedding material pet hair etc BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air in...

Страница 28: ...or placement instructions Replace log set if broken or chipped dime sized or larger CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth dampened with a m...

Страница 29: ...f pinched by any metal or tubing Keep igniter cable dry 3 Replace igniter cable 4 Replace piezo igniter 5 Replace pilot assembly 6 Replace pilot assembly When igniter button is pressed there is spark...

Страница 30: ...ean ing and Maintenance Page 27 or replace ODS pilot as sembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve Burner does not light after ODS pil...

Страница 31: ...eplace blocked 4 Dirty or partially clogged burner orifice 1 Turn control knob to LO posi tion and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by loc...

Страница 32: ...exces sive contact qualified service person Fireplace produces unwanted odors 1 Fireplace burning vapors from paint hair spray glues clean ers chemicals newcarpet etc See IMPORTANT statement above 2 L...

Страница 33: ...ignition appliance will not produce specified heat propane LP gas supply may be low You may feel your gas pressure is too low If so contactyourlocalpropane LPornaturalgassupplier TECHNICAL SERVICE You...

Страница 34: ...t No F2236 Model RCKIT4001 For all models Allows appliance to be operated in a manually controlled mode RECEIVER AND HAND HELD THERMOSTATIC ON OFF REMOTE CONTROL KIT TRC Cat No F1078 Model TRC For all...

Страница 35: ...32 13 41 21 5 26 19 18 15 27 1 27 2 43 3 43 29 16 18 3 17 42 36 4 4 44 43 Cat No Model Description F1217 VCM3026ZMN 26 Millivolt NG F1218 VCM3026ZMP 26 Millivolt LP WARNING Failure to position the pa...

Страница 36: ...1 J3837 Gas Valve LP 1 23 J3757 Baffle 1 24 J3725 Flexible Connector 1 25 J3868 Control Shield 1 26 J3802 Screen Assembly 1 27 J4008 Log Set Assembly Kit 1 28 J3869 Right Hinge 1 29 J3870 Left Hinge 1...

Страница 37: ...tural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c...

Страница 38: ...ts Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126872 01 Rev C 12 2019 SuperiorFireplaces us com Record the following important i...

Отзывы: