FIREPLACE INSTALLATION

SELECTING LOCATION

To determine safest and most efficient location for fireplace, you 

must take into consideration the following guidelines:
1.  Location must allow for proper clearances (see Figures 1 and 2).
2.  Consider a location where fireplace will not be affected by drafts, 

air conditioning ducts, windows or doors.

3.  A location that avoids cutting of joists or roof rafters will make 

installation easier.

4.  An outside air kit is available with this fireplace (see Optional 

Outside Air Kit on page 7).

MINIMUM CLEARANCE TO COMBUSTIBLES

Back and sides of fireplace                                  3/4" (19 mm) minimum*
Floor**                                                                    0" (0 mm) minimum
Perpendicular wall to opening                              12" (305 mm) minimum
Top spacers                                                             0" (0 mm) minimum
Mantel clearances                                             see Mantels, page 6
Chimney outer pipe surface                            1" (26 mm) minimum

* Not required at nailing flanges

** See step 2 of Framing

 WARNING: DO NOT PACK REQUIRED AIR SPACES 

WITH INSULATION OR OTHER MATERIALS.

Minimum/Maximum Chimney Height

Minimum height of chimney, measured from base of fireplace to 

flue gas outlet of termination, is 14-½ feet for straight flue or a flue 

with one elbow set. Maximum distance between elbows is 6 feet. For 

systems with two elbow sets, minimum height is 22 feet. Maximum 

height of any system is 50 feet. This measurement includes fireplace, 

chimney sections and height of termination assembly at level of flue 

gas outlet (see Figure 20, page 12).

FRAMING

1.  Frame opening for fireplace using dimensions shown in Figures 

1 and 2.

2.  If fireplace is to be installed directly on carpeting, tile or any 

combustible material other than wood flooring, fireplace must 

be installed upon a metal or wood panel extending full width and 

depth of fireplace.

3.  Set fireplace directly in front of this opening and slide unit back 

until nailing flanges touch side framing.

4.  Check level of fireplace and shim with sheet metal if necessary.
5.  Before securing fireplace to prepared framing, ember protector 

must be placed between hearth extension (not included) and 

under bottom front edge of fireplace to protect against glowing 

embers falling through. If fireplace is to be installed on a raised 

platform, a Z-type ember protector (not included) must be fabri-

cated to fit your required platform height. Ember protector should 

extend under fireplace a minimum of 1 

1

/

2

". Ember protector 

should be made of galvanized sheet metal (28 gauge minimum) 

to prevent corrosion.

6.  Using screws or nails, secure fireplace to framing through flanges 

located on sides of fireplace.

Figure 1 - Framing Dimensions

Figure 2 - Corner Installation

HEARTH EXTENSION

A hearth extension projecting a minimum of 16" in front of and a 

minimum of 8" beyond each side of fireplace opening is required to 

protect combustible floor construction in front of fireplace. Fabri-

cate a hearth extension using a material which meets the following 

specifications: a layer of noncombustible, inorganic material having 

a thermal conductivity of k = .84 BTU IN/FT

2

 HR °F (or less) at 1" 

thick. For example, if material selected has a k factor of 0.25, such 

as glass fiber, the following formula would apply:
  0.25 x 1.0" = 0.30" thickness required

 0.84
Thermal conductivity "k" of materials can be obtained from manu-

facturer or supplier of noncombustible material. If hearth extension 

is to be covered, use noncombustible material such as tile, slate, 

brick, concrete, metal, glass, marble, stone, etc. Provide a means to 

prevent hearth extension from shifting and seal gap between fireplace 

frame and hearth extension with a non-combustible material such 

as sand-cement grout (see Figure 3, page 6).

41 

3

/

4

"

(1061 mm)  

41 

3

/

4

"

(1061 mm)  

21 

7

/

8

"

(556 mm)  

Maintain 

3

/

4

Clearance at 

Sides and 

Back of 

Fireplace

   

3

/

4

" Clearance Not 

Required at Nailing Flanges 

  

 24 

1

/

2

(623 mm) 

 52 

1

/

4

(1328 mm) 

 17 

3

/

8

(442 mm) 

 73 

7

/

8

" (1877 mm) 

Содержание Pro Series

Страница 1: ...ge 20 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorité compétente comme le service municipal du bâtiment les pompiers etc doit être contacté avant l installation afin de déterminer la nécessité d obtenir un permis This appliance may be...

Страница 2: ...d tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step...

Страница 3: ...anposeasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fre...

Страница 4: ... 8 232 mm 3 1 2 89 mm 3 1 2 89 mm 11 1 2 292 mm 22 559 mm 29 737 mm 41 1042 mm 1 26 mm 1 26 mm 21 534 mm 8 204 mm 35 889 mm 37 940 mm 41 1042 mm 1 26 mm AIRSPACE TO COMBUSTIBLE MATERIAL 0 0 mm TO TOP SPACERS 0 0 mm TO BOTTOM 8 204 mm EACH SIDE NO COMBUSTIBLE MATERIAL ON FACE HEARTH EXTENSION 51 X 16 1296 mm X 407 mm COMBUSTIBLE WALL BOARD NOT LESS THAN 12 305 mm TO PERPENDICULAR SIDEWALL OUTSIDE A...

Страница 5: ... nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extension not included and under bottom front edge of fireplace to protect against glowing embers falling through If fireplace is to be installed on a raised platform a Z type ember protector not included...

Страница 6: ...ess than 12 from top opening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material also may come up to side edge of black metal face of fireplace as long as projections from front face fall within limit shown in Figure 5a 12 1 4 312 mm Ref 15 381 mm Min 12 305 mm Min 6 153 mm Ref 11 2 38 mm Max 3 77 mm Nom 33 Combustible Material Safe Zone for ...

Страница 7: ...attic space The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination CHIMNEY PIPE WARNING Label part number 900599 01 must be applied by the installer to all chimney pipe sections but is not required on sections that will be visible after the installation is complete Label must wrap around the circumference of the pipe See accessories page 20 for Kit F...

Страница 8: ...ce inner flue pipe section must be installed first with lanced side up Outer pipe section can then be installed over flue pipe section with hemmed end up Press down on each pipe section until lances securely engage hem on fireplace starter Wire will assure proper spacing between inner and outer pipe sections Note For Canada use chimney parts designated HT Continue to assemble chimney sections as o...

Страница 9: ...g Support Pipe 12S 8DM 1 26 mm Min Straps Straps Straps Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B Ceiling Support Pipe 12S 8DM VENTING INSTALLATION Continued Offset Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m Ceiling Support Pipe 12S 8DM ...

Страница 10: ...in Figure 13 Figure 12 Firestop Spacer with Living Space Above Ceiling Figure 13 Firestop Spacer with Attic Space Above Ceiling If area above is a living space install firestop below framed hole If area above is an attic or insulated area install firestop above framed hole PENETRATING ROOF To maintain a 1 clearance to pipe on a roof with a pitch a rectangular opening must be cut 1 Determine center...

Страница 11: ...na tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrestor Fireplace system must be terminated with listed round top or chase terminations In any case refer to installation instructions supplied with termination Terminations approved for this fireplace are RT 8DM and RLT ...

Страница 12: ...ials such as wallboard sheet rock drywall ply wood etc may make direct contact with sides and top around fire place face It is important that combustible materials do not overlap face itself Brick glass tile or other noncombustible materials may overlap front face provided they do not obstruct essential openings such as louvered slots When overlapping with a noncombustible facing material use only...

Страница 13: ...ment Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solutiontoallconnectionsandjoints Bubblesforming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED LEAK ...

Страница 14: ...ass doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too large a fire is built or if combustion air gate is not completely open The following tips should be used to assure that both fireplace and glass door retain their beauty and function properly Both the flue ...

Страница 15: ...e used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the shroud NOTICE The firebox canopy hood must not be modified or replaced with a canopy that may be provided with the unvented decorative room heater CAUTION THE STRUCTURAL INTEGRITY OF THE MANU FACTUR...

Страница 16: ...RTS WOOD BURNING FIREPLACE MODELS MODEL CATALOG NO WRT3036WS F0659 WRT3036WSI F0660 WRT3036WH F0661 WCT3036WS F0662 WCT3036WSI F0663 WCT3036WH F0664 9 4 28 29 19 12 20 26 17 8 1 5 21 2 30 18 11 14 3 13 22 10 6 27 7 32 33 31 34 24 25 15 16 16 23 ...

Страница 17: ...amper Can Collar 1 16 J8007 Screen Assembly Kit 1 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 J3991 Smoke Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 J4381 Grate 1 24 Collar Insulation 1 25 J6893 Chimney Starter Collar 1 26 J6895 Refractory Retainer 2 27 J7003 Grate Retainer 2 28 Door Stop 1 29 J6905 Spring Clip 2 30 J6918 Top Standoff 4 31 J6934 C...

Страница 18: ...Right Stacked White 1 4 Refractory Rear Stacked White 1 5 Refractory Bottom Rear White 1 6 Refractory Bottom Front White 1 WARNING Contact an IHP dealer to obtain any of these parts Never use substitute materials not approved by IHP Use of non approved parts can result in poor performance and safety hazards REFRACTORY STAIN KITS Use the refractory stain kits to give white refractory panels a new l...

Страница 19: ...8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 Degree Offset and Return F0886 30E 8HT 30 Degree Hi Temp Offset and Return OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION F1091 AK4 Co...

Страница 20: ...p Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TERMINATION WITH SLIP SECTION F0923 ETLO 8DM Square Top with Mesh and Slip Section ADJUSTABLE HOOD Required when installing a vent free gas log in this fireplace F1764 GA6050 Black Fireplace Hood F1766 GA6053 Brushed Brass Fireplace Hood FAN KIT F1083 B...

Страница 21: ...onditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance See Chimney Guidelines to assist you in selecting the proper venting system for your installation American National Stan...

Страница 22: ...iance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts some models outside air kit and chimney Ifpossible youshouldchoosealocationwherethechi...

Страница 23: ... be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Pro...

Страница 24: ...26619 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products LLC P N 126619 01 Rev K 02 2019 1769 East Lawrence Street Russellville AL 35654 ...

Отзывы: