10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
* 3" (77 mm) above any horizontal/inclined vent component.
** See Page 11, Step 1 for clearance requirements to the nailing flange
located at each side of the unit and any screw heads adjacent to it.
Wall Finishes / Surrounds / Mantels
NOTE: Combustible wall finish materials and/or surround materials
must not be allowed to encroach the area defined by the appliance
front face (black sheet metal). Never allow combustible materials to
be positioned in front of or overlapping the appliance face. See
Figure
6
and
Figure 44
on
Page 28.
Noncombustible materials, such as surrounds and other appliance trim,
may be installed on the appliance front face with these exceptions: they
must not cover any portion of the removable glass panel.
Vertical installation clearances to combustible mantels vary according to
the depth of the mantel (see
Figure 5
)
. Mantels constructed of noncom-
bustible materials may be installed at any height above the appliance.
Minimum clearance requirements include any projections such as shelves,
window sills, mantels, etc. above the appliance.
NOTE: To avoid heat-related finish damage, we recommend the use of high
temperature paint (rated 175° F or higher) on the underside of the mantel.
MINIMUM CLEARANCES TO COMBUSTIBLES
Appliance And Vent Clearances
The appliance is approved with zero clearance to combustible
materials on all sides. Refer to
Table 5
for minimum clearance values.
For typical installations, see
Figure 2
on
Page 7
.
Figure 6 - Minimum Distance to Unprotected Side Wall
Figure 5 - Minimum Mantel Clearances
INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRC/DRT6340TYN AND DRC/DRT6345TYN) • INSTALLATION INSTRUCTIONS
MINIMUM CLEARANCES
*
Inches (millimeters)
Sides
1/2" (13 mm)
0" (0 mm) Spacers **
Top Spacers
0" (0 mm)
Floor
0" (0 mm)
Back
1/2" (13 mm)
0" (0 mm) Spacers
Bottom of Appliance To Ceiling
64" (1626 mm)
Vent
3" (77 mm) Top*
1" (26 mm) Sides and Bottom
SERVICE CLEARANCES Feet (meters)
Front
3 feet (0.9 meters)
Table 5
3-1/2”
(89 mm)
Top View of
Fireplace
Combustible materials
may project beyond
either side of the
fireplace opening as
long as they are kept
within the shaded
“Safe Zone” area.
At 0” minimum
side wall clearance,
one combustible
wall can project to
any length.
45
o
Mantel Leg,
Trim, or Wall
12 (305) MANTEL
10 (254) MANTEL
8 (203) MANTEL
6 (152) MANTEL
4 (102) MANTEL
4
(102)
14
(356)
12
(305)
10
(254)
2 (51) MANTEL
TOP OF
APPLIANCE
6
(152)
8
(203)
MANTEL CLEARANCES
Inches (mm)
NOTE: Hood shown as positioned in louvered
front model. The hood position in the flush
faced front model is lower than shown.