10.0. 

REPLACEMENT PARTS 

10.1.  ORDERING 

Because  this  manual  covers  a  full  series  of  units  it  is 
impractical to provide a full list of replacement parts. To 
order  a  part  not  listed  in  this  manual,  provide  the  unit 
model  number,  serial  number,  and  date  code. 
Reference  the  part  by  schematic  reference  symbol, 
description and part number if available. 
 

10.2.  CONTROL MODULE ASSEMBLY 

The  same  control  modules  are  used  throughout  this 
standard  WHR  Series  STABILINE

®

  Automatic  Voltage 

Regulators  and  are  shown  below. 

Tropicalized  units

 

have a similar control module but some of the parts are 
specially  treated  and  therefore  have  a 

different  part 

number

 

 

 

FLOOR MOUNT CONTROL MODULE ASSEMBLY (A1) 

 

 

 

Standard 

Tropicalized 

Reference Symbol 

Part Description 

Part Number 

Part Number 

 

 

 

 

A1 

CONTROL MODULE 

213243-003 

213243-006 

A1-A1 

CONTROL BOARD 

227412-001 

227412-001-SM 

A1-F1,F2,F3,F4 

FUSE, 600V 

104364-003 

 

A1-LP1,LP2 

LIGHT, INDICATOR, GREEN 

227571-001 

 

A1-M1 

VOLTMETER 

212917-004 

 

A1-S1 

SWITCH, ROCKER SPST ON/-/ON 

227572-002 

 

 

10.3.  POWER COMPONENTS 

The following parts differ depending on the model. Part number can be determined by the letter designations for 
range and size code in the base model number. Ex. WHR32

W

T

F

33 

 

Standard Unit 

Part Number for Range & Size Code letters listed

 

Reference 
Symbol 

Part Description 

W

T

W

T

N

T

N

T

N

T

T1 

POWERSTAT, VARIABLE 
TRANSFORMER 

212995-001 

216973-001 

216513-003 

216973-002 

216969-002 

 

REPLACEMENT BRUSH ASSEMBLY 

017702-011 

017702-003 

017702-011 

017702-003 

176012-001 

T2 

CHOKE, PARALLELING 

006724-000 

 

006724-000 

 

 

 

Tropicalized Units only … 

Part Number for Range & Size Code letters listed

 

Reference 
Symbol 

Part Description 

W

T

W

T

N

T

N

T

N

T

T1 

POWERSTAT, VARIABLE 
TRANSFORMER 

218312-014 

218312-008 

218312-013 

218312-009 

218312-003 

 

REPLACEMENT BRUSH ASSEMBLY 

017702-013 

017702-007 

017702-013 

017702-007 

176003-003 

T2 

CHOKE, PARALLELING 

006724-000 

 

006724-000 

 

 

Содержание STABILINE WHR32 Series

Страница 1: ...owing WHR62 T WHR92 T WHRS32 T WHRS62 T or WHRS92 T Superior Electric reserves the right to make engineering changes on all its products Such refinements may affect information given in the instructio...

Страница 2: ...2...

Страница 3: ...nd Shortage instructions packed with the unit outlines the procedure to follow if any parts are missing or damaged 2 0 DESCRIPTION 2 1 GENERAL WHR32 T Series STABILINE Automatic Voltage Regulators are...

Страница 4: ...S Single Control D Double Control T Triple Control LNN Size Code 3 or 4 digits R Rack Cabinet T Tall Cabinet CB Input Circuit Breaker CS Input Circuit Breaker w 120vac Shunt Trip CR Input Circuit Brea...

Страница 5: ...ange of knockouts are provided in the base and the rear panel of the unit for wire entry and exit The location of the power connections varies depending on the options provided On units with an input...

Страница 6: ...SETTING OUTPUT VOLTAGE AND SENSITIVITY POTENTIOMETERS Normally the WHR Series voltage regulator should not be operated without the front panel s of the cabinet in place However during the initial oper...

Страница 7: ...are wired to trip the input breaker The Shunt Trip Connections Diagram shows the typical connections 6 2 1 2 Under Voltage Trip L1 In unit where the model number designates the circuit breaker as CR...

Страница 8: ...g without storing them in memory If the user changed the factory settings and did not select the store option the factory setting can be reinstated by pressing both RECALL buttons at the same time The...

Страница 9: ...onnected for all boost the units will bring extra low voltages up to nominal but will not correct high input voltages Since operation in the all boost mode will increase the voltage and heating in the...

Страница 10: ...ess the unit is overloaded there is little likelihood of component failure Warning Voltages are present inside this unit which can cause injury Therefore only personnel qualified to service electrical...

Страница 11: ...e motor at the end of travel If the motor operates successfully in this test the problem may be with the control board 8 10 Inspect the POWERSTAT Variable Transformer brush s and commutator s for sign...

Страница 12: ...50 2700 INPUT VOLTAGE 208Y 120 X 240Y 138 FREQUENCY 50 60 Hz X 60 Hz CONNECTION 3 Phase 4 Wire Wye RANGE 20 to 10 of Selected Output OUTPUT VOLTAGE 208Y 120 X 240Y 138 CONNECTION 3 Phase 3 or 4 Wire M...

Страница 13: ...ilated enclosures intended for indoor use under usual service conditions Temperature Operating Average ambient temperature for any 24 hour period not to exceed 30 C 86 F and maximum temperature not to...

Страница 14: ...1 227412 001 SM A1 F1 F2 F3 F4 FUSE 600V 104364 003 A1 LP1 LP2 LIGHT INDICATOR GREEN 227571 001 A1 M1 VOLTMETER 212917 004 A1 S1 SWITCH ROCKER SPST ON ON 227572 002 10 3 POWER COMPONENTS The following...

Страница 15: ...r details The replacement brush assembly is listed along with its corresponding POWERSTAT Variable Transformer in the power component section 10 5 AUX POWER MODULE There are two standard power modules...

Страница 16: ...16 11 0 SCHEMATIC For reference only use full size supplied with unit...

Страница 17: ...17 12 0 FLOOR MOUNT DIMENSIONS Enclosures A through G Note All dimensions are inches millimeters...

Страница 18: ...18 Enclosures A through G continues Note All dimensions are inches millimeters...

Страница 19: ...19 Enclosures A through G continues Note All dimensions are inches millimeters...

Страница 20: ...20 Enclosures DPLUS through GPLUS Note All dimensions are inches millimeters...

Страница 21: ...21 Enclosures DPLUS through GPLUS continues Note All dimensions are inches millimeters...

Страница 22: ...22 Enclosures DD through GG Note All dimensions are inches millimeters...

Страница 23: ...23 Enclosures DD through GG continues Note All dimensions are inches millimeters...

Страница 24: ...24 Enclosures EEE through GGG Note All dimensions are inches millimeters...

Страница 25: ...25 Enclosures EEE through GGG continues Note All dimensions are inches millimeters...

Страница 26: ...offer literature technical assistance and a select range of models off the shelf for fastest possible delivery and service In addition Superior Electric Manufacturer s Representatives are available t...

Отзывы: