background image

 

12

9.0. 

RATING

 

 

9.1.  POWER RATINGS

 

The WHR32*T*** Series ratings are shown below: 
 

INPUT: 

VOLTAGE: 

208Y/120  X  240Y/138 

FREQUENCY:  50/60 Hz 

X  60 Hz 

CONNECTION:  3 Phase, 4 Wire, Wye 
RANGE: 

-30% to +15% of Selected Output 

OUTPUT: 

VOLTAGE: 

208Y/120  X  240Y/138 

CONNECTION:  3 Phase, 3 or 4 Wire 

 

Model Number 
(base unit) 

Rated Load 

Max. 
Input 
Amps 

Amps 

kVA at 

208 V 

240 V 

WHR32WTE31 

42 

15 

60 

WHR32WTF31 

72 

25 

30 

100 

WHR32WTF32 

144 

50 

60 

200 

WHR32WTF33 

216 

75 

90 

300 

WHR32WTF34 

288 

100 

120 

400 

WHR32WTF35 

360 

125 

150 

500 

WHR32WTF36 

432 

150 

175 

600 

WHR32WTF37 

504 

175 

200 

700 

WHR32WTF38 

576 

200 

225 

800 

WHR32WTF39 

648 

225 

250 

900 

WHR32WTF65 

720 

250 

300 

1000 

WHR32WTF66 

850 

300 

350 

1200 

WHR32WTF67 

1000 

350 

400 

1400 

WHR32WTF68 

1150 

400 

450 

1600 

WHR32WTF96 

1300 

450 

525 

1800 

WHR32WTF97 

1500 

525 

600 

2100 

WHR32WTF98 

1700 

600 

675 

2400 

WHR32WTF99 

1900 

675 

750 

2700 

 

 

INPUT: 

VOLTAGE: 

208Y/120  X  240Y/138 

FREQUENCY:  50/60 Hz 

X  60 Hz 

CONNECTION:  3 Phase, 4 Wire, Wye 
RANGE: 

-20% to +10% of Selected Output 

OUTPUT: 

VOLTAGE: 

208Y/120  X  240Y/138 

CONNECTION:  3 Phase, 3 or 4 Wire 

 

 
Model Number 
(base unit) 

Rated Load 

Max. 
Input 
Amps 

Amps 

kVA at 

208 V 

240 V 

WHR32NTD31 

30 

10 

13 

37 

WHR32NTE31 

50 

18 

20 

60 

WHR32NTF31 

80 

28 

33 

100 

WHR32NTF32 

160 

55 

65 

200 

WHR32NTF33 

240 

85 

100 

300 

WHR32NTF34 

320 

110 

125 

400 

WHR32NTF35 

400 

140 

150 

500 

WHR32NTF36 

480 

170 

200 

600 

WHR32NTF37 

560 

200 

225 

700 

WHR32NTF38 

640 

225 

250 

800 

WHR32NTF39 

720 

250 

300 

900 

WHR32NTF65 

800 

285 

325 

1000 

WHR32NTF66 

960 

350 

400 

1200 

WHR32NTF67 

1120 

400 

450 

1400 

WHR32NTF68 

1280 

450 

525 

1600 

WHR32NTF96 

1450 

525 

600 

1800 

WHR32NTF97 

1680 

600 

675 

2100 

WHR32NTF98 

1900 

675 

750 

2400 

WHR32NTF99 

2150 

750 

850 

2700 

 

 
9.2.  VOLTAGE RANGE CHART

 

At the very extremes of the input range the output 
voltage may become slightly higher or lower than would 

  

otherwise be the case. This voltage range chart shows 
the output voltages produced over the input range. 

 

Содержание STABILINE WHR32 Series

Страница 1: ...owing WHR62 T WHR92 T WHRS32 T WHRS62 T or WHRS92 T Superior Electric reserves the right to make engineering changes on all its products Such refinements may affect information given in the instructio...

Страница 2: ...2...

Страница 3: ...nd Shortage instructions packed with the unit outlines the procedure to follow if any parts are missing or damaged 2 0 DESCRIPTION 2 1 GENERAL WHR32 T Series STABILINE Automatic Voltage Regulators are...

Страница 4: ...S Single Control D Double Control T Triple Control LNN Size Code 3 or 4 digits R Rack Cabinet T Tall Cabinet CB Input Circuit Breaker CS Input Circuit Breaker w 120vac Shunt Trip CR Input Circuit Brea...

Страница 5: ...ange of knockouts are provided in the base and the rear panel of the unit for wire entry and exit The location of the power connections varies depending on the options provided On units with an input...

Страница 6: ...SETTING OUTPUT VOLTAGE AND SENSITIVITY POTENTIOMETERS Normally the WHR Series voltage regulator should not be operated without the front panel s of the cabinet in place However during the initial oper...

Страница 7: ...are wired to trip the input breaker The Shunt Trip Connections Diagram shows the typical connections 6 2 1 2 Under Voltage Trip L1 In unit where the model number designates the circuit breaker as CR...

Страница 8: ...g without storing them in memory If the user changed the factory settings and did not select the store option the factory setting can be reinstated by pressing both RECALL buttons at the same time The...

Страница 9: ...onnected for all boost the units will bring extra low voltages up to nominal but will not correct high input voltages Since operation in the all boost mode will increase the voltage and heating in the...

Страница 10: ...ess the unit is overloaded there is little likelihood of component failure Warning Voltages are present inside this unit which can cause injury Therefore only personnel qualified to service electrical...

Страница 11: ...e motor at the end of travel If the motor operates successfully in this test the problem may be with the control board 8 10 Inspect the POWERSTAT Variable Transformer brush s and commutator s for sign...

Страница 12: ...50 2700 INPUT VOLTAGE 208Y 120 X 240Y 138 FREQUENCY 50 60 Hz X 60 Hz CONNECTION 3 Phase 4 Wire Wye RANGE 20 to 10 of Selected Output OUTPUT VOLTAGE 208Y 120 X 240Y 138 CONNECTION 3 Phase 3 or 4 Wire M...

Страница 13: ...ilated enclosures intended for indoor use under usual service conditions Temperature Operating Average ambient temperature for any 24 hour period not to exceed 30 C 86 F and maximum temperature not to...

Страница 14: ...1 227412 001 SM A1 F1 F2 F3 F4 FUSE 600V 104364 003 A1 LP1 LP2 LIGHT INDICATOR GREEN 227571 001 A1 M1 VOLTMETER 212917 004 A1 S1 SWITCH ROCKER SPST ON ON 227572 002 10 3 POWER COMPONENTS The following...

Страница 15: ...r details The replacement brush assembly is listed along with its corresponding POWERSTAT Variable Transformer in the power component section 10 5 AUX POWER MODULE There are two standard power modules...

Страница 16: ...16 11 0 SCHEMATIC For reference only use full size supplied with unit...

Страница 17: ...17 12 0 FLOOR MOUNT DIMENSIONS Enclosures A through G Note All dimensions are inches millimeters...

Страница 18: ...18 Enclosures A through G continues Note All dimensions are inches millimeters...

Страница 19: ...19 Enclosures A through G continues Note All dimensions are inches millimeters...

Страница 20: ...20 Enclosures DPLUS through GPLUS Note All dimensions are inches millimeters...

Страница 21: ...21 Enclosures DPLUS through GPLUS continues Note All dimensions are inches millimeters...

Страница 22: ...22 Enclosures DD through GG Note All dimensions are inches millimeters...

Страница 23: ...23 Enclosures DD through GG continues Note All dimensions are inches millimeters...

Страница 24: ...24 Enclosures EEE through GGG Note All dimensions are inches millimeters...

Страница 25: ...25 Enclosures EEE through GGG continues Note All dimensions are inches millimeters...

Страница 26: ...offer literature technical assistance and a select range of models off the shelf for fastest possible delivery and service In addition Superior Electric Manufacturer s Representatives are available t...

Отзывы: