Superabrasive
Owner’s manual original language – Lavina
®
V20E
01/2020
11
• Perform general daily inspections of the vacuum and inspect the vacuum before each use for any
sign of damage.
• Inspect all safety devices.
• The vacuum/filters must be clean and the hose should be connected.
5.7 OPERATING THE VACUUM
When operating the LAVINA® V20Е, be sure that no one else is within close proximity to the
vacuum. Never leave the vacuum unattended while working. The hose must move freely, be
damage-free, and should never run beneath the vacuum or machine. Check the floor prior to
beginning any work, and ensure that it’s not too uneven, which can cause damage to the vacuum.
5.8 AFTER WORK IS COMPLETED
When work is complete, clean the vacuum and its surroundings sufficiently, empty all dust / debris,
secure the hose, and store the vacuum in a safe and secure place.
5.9 THE WORK AREA
Ensure that the area is free of unauthorized people or vehicles, hoses, and always check the floor for
debris.
5.10 PERSONAL PROTECTIVE EQUIPMENT (PPE)
When operating the machine, always wear safety shoes, ear protectors, safety gloves (especially
when changing tools), and suitable clothing. All persons within the immediate working area must
wear safety glasses with side shields.
5.11 OPERATOR
The operator must be aware of the vacuum’s work environment, be properly trained prior to
operating the equipment, and fully understand this manual. Only one operator may work with the
machine at a single time. The operator must understand and interpret all the drawings and designs in
manual, understand all sanitation and safety regulations pertaining to its operation, have floor
grinding experience, know how to perform in an emergency situation, and have an adequate
technical knowledge.
• The dust collector should only be operated in environments with a temperature between 41°F and
113°F (5°C to 45°C) and a maximum relative humidity of 70%.
• The work environment for the vacuum should be clean, well-lit, and free of combustible elements.
• The dust collector should not be operated without the proper filters installed. This could possibly
result in damage to the machine, and cause harm to surrounding personnel.
• Do not open the waste container or motor head assembly while the vacuum is operating.
• Do not vacuum any flammable materials or substances such as fuels, solvents, etc. A dust collector
must be specifically designed and labeled for such operation. When grinding epoxy, first ensure that
the epoxy is non-toxic.
• Do not vacuum any corrosive substances unless the vacuum is specifically outfitted with containers
suitable for this purpose.
• Do not vacuum any burning, smoldering, or hot materials. This could result in a possible explosion
and/or damage to the vacuum components.
Содержание LAVINA V20E
Страница 2: ...Superabrasive Owner s manual original language Lavina V20E 01 2020 2...
Страница 23: ...Superabrasive Owner s manual original language Lavina V20E 01 2020 23 8 2 VACUUM MOTORS SERVISING Figure 8 2...
Страница 26: ...Superabrasive Owner s manual original language Lavina V20E 01 2020 26 10 LAVINA VACUUM ADAPTERS AND CONNECTIONS...
Страница 29: ...Superabrasive Owner s manual original language Lavina V20E 01 2020 29 11 2 VACUUM HEAD COVER Figure 11 2...
Страница 31: ...Superabrasive Owner s manual original language Lavina V20E 01 2020 31 11 3 MAIN FILTER CHAMBER Figure 11 3...
Страница 33: ...Superabrasive Owner s manual original language Lavina V20E 01 2020 33 11 5 CARRIAGE 19 Figure 11 5...
Страница 35: ...Superabrasive Owner s manual original language Lavina V20E 01 2020 35 11 6 POWER UNIT Figure 11 6...
Страница 37: ...Superabrasive Owner s manual original language Lavina V20E 01 2020 37 11 7 CONTROL BOARD...