background image

POSITIVE PRESSURE VENTILATOR

7

718G4T_PPVentilatorUserGuide-Tecumseh.doc

REV. 03/18/03

3.

 

Move throttle control to the SLOW position.

4.

 

Pull the starter grip lightly until resistance is felt, then pull briskly. Do not let the starter grip return by releasing grip,
this can lead to starter cord breakage. Return starter grip gently to the recoiled position.

Содержание 718G4T

Страница 1: ...VENTILATOR USER GUIDE MODEL 718G4T ...

Страница 2: ...the ventilator Save this guide for future reference CONTENTS 1 BREAKAGE OR DAMAGE DURING SHIPMENT 2 2 GENERAL DESCRIPTION AND SPECIFICATIONS 3 3 PRODUCT SAFETY PRECAUTIONS 4 4 BEFORE OPERATING VENTILATOR 4 5 OPERATION 5 STARTING THE ENGINE 6 STOPPING THE ENGINE 8 6 MAINTENANCE AND REPAIR 9 SCHEDULE OF MAINTENANCE 9 7 TROUBLESHOOTING 10 8 WARRANTY 11 9 CONTACT INFORMATION 12 10 PARTS LIST 13 11 EXP...

Страница 3: ...or damages If we filed claim here it would be sent to your local freight agent for verification and investigation This time can be saved by your filing the claim directly Every consignee is on the ground floor and in contact with the local agent who inspects the damaged goods and thus each claim can be given individual attention Since our goods are packed to comply with the regulations of all rail...

Страница 4: ...is designed for high powered air movement Super Vac s propeller produces a greater intake of air and eliminates turbulence at the tips Each blade is statically balanced for high efficiency and long life This document is designed to function as a quick start guide and not an in depth comprehensive instructional manual Please read all accompanying documents shipped with your ventilator Due to the ma...

Страница 5: ...ug and keep it away from spark plug before removing foreign object Ø Do not use with any fuel supply source other than the provided fuel tank Ø Engine exhaust gas contains poisonous carbon monoxide Avoid inhalation of exhaust gas Never run the engine in a closed or confined area Ø Do not place or operate ventilator on unsteady tables slanted surfaces or other unstable surfaces Ø Never use this ven...

Страница 6: ...full tank will help reduce operating interruptions for refueling and avoid fuel spillage when engine is tilted See page 2 of the TECUMSEH Operator s Manual Place ventilator in desired location before starting Refer to the TECUMSEH Operator s Manual for additional information showing locations of engine control features and positions This engine is equipped with an Low Oil Shutdown which is designe...

Страница 7: ...SURE VENTILATOR 6 718G4T_PPVentilatorUserGuide Tecumseh doc REV 03 18 03 Starting the engine 1 Turn the fuel lever counter clockwise to the ON position 2 If engine is cold move choke lever to the FULL CHOKE position ...

Страница 8: ...EV 03 18 03 3 Move throttle control to the SLOW position 4 Pull the starter grip lightly until resistance is felt then pull briskly Do not let the starter grip return by releasing grip this can lead to starter cord breakage Return starter grip gently to the recoiled position ...

Страница 9: ...Move throttle lever to the STOP position 2 Turn the fuel valve lever clockwise to the OFF position Use caution not to direct toxic fumes into confined spaces with the ventilator Please refer to the Super Vac Training Manual for Smoke Ventilation for comprehensive instruction on effective ventilation practices ...

Страница 10: ...h may cause an imbalance Excessive imbalance can lead to accelerated wear on engine bearings and vibration Remove ventilator guards Clean blade and inside housing with mild detergent and water Do not use abrasives sharp instruments or caustic solvents that may scratch or damage the aluminum alloy blade Schedule of Maintenance Perform at every indicated hour interval Each use 1st 2 Hrs Every 50 Hrs...

Страница 11: ... Correction Check control positions Fuel valve OFF Move lever to ON Choke is OFF Set choke to FULL on Unless engine is warm Throttle control is on STOP Move throttle control to SLOW Low Oil Shutdown Engine oil is low or engine is being operated on too steep an incline Check fuel Out of fuel Refuel Deteriorated fuel Drain fuel tank and carburetor Refuel with fresh gasoline Contamination in fuel tan...

Страница 12: ...s is pre run and tested before leaving our plant and is shipped in good working order and condition We therefore extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purchase 1 This warranty does not apply to defects caused by accident misuse neglect or wear and tear nor can we be held responsible for incidental and consequential e...

Страница 13: ...latorUserGuide Tecumseh doc REV 03 18 03 9 Contact Information For parts or service information contact Super Vacuum Manufacturing Company Inc PO Box 87 Loveland CO 80539 Phone 1 800 525 5224 970 667 5146 FAX 970 667 4296 Internet www supervac com ...

Страница 14: ...H ZINC 30 008 10189 6 PLUG FINISHING SQ RIBBED BLACK 1 31 024 13473 2 FEET RUBBER CONE SHAPE VBM 4002 32 032 13052 2 5 16 24 NYLOK HEX NUT ZINC 33 018 10404 1 TUBE FRAME 18 PAINTED 34 032 14564 2 3 8 16 X 2 1 2 SOCKET BUTTON HEAD CS ZN 35 018 15000 2 718 SHROUD SUPPORT BRACKET 36 008 10212 2 WASHER FLAT 17W14930 MICRO PLASTIC 37 032 11129 2 3 8 FLAT WASHERUSS ZINC 38 032 11133 2 3 8 16 NYLOK HEX N...

Страница 15: ...POSITIVE PRESSURE VENTILATOR 14 718G4T_PPVentilatorUserGuide Tecumseh doc REV 03 18 03 CAUTION CONSULT ENGINE OWNERS MANUAL BEFORE OPERATING 11 Exploded View ...