background image

                                                                                   

4/22

 

hold

 

the

 

weight

 

of

 

the

 

Generator.

 

If

 

the

 

floor/ground

 

surface

 

is

 

not

 

level,

 

strong

 

cross

 

members

 

should

 

be

 

placed

 

under

 

the

 

full

 

length

 

of

 

the

 

Generator

 

Frame

 

at

 

its

 

low

 

side.

 

7.

 

For

 

trailer

 

installation,

 

the

 

Generator

 

should

 

be

 

mounted

 

on

 

the

 

center

 

point

 

of

 

the

 

trailer,

 

over

 

the

 

wheels.

 

OPERATION

 

STARTING

 

THE

 

ENGINE

 

1.

 

Starting

 

with

 

hand

 

Turn

 

the

 

Engine

 

Switch

 

to

 

the

 

ON

 

position.

 

The

 

engine

 

switch

 

enables

 

and

 

disables

 

the

 

ignition

 

system.

 

OFF:

 

To

 

stop

 

the

 

engine.

 

ON:

 

To

 

run

 

the

 

engine.

 

 
 

 

Electric

 

start

 

Key

 

position

 

:

 

OFF:

 

To

 

Stop

 

the

 

engine.

 

Key

 

can

 

be

 

removed/inserted.

 

ON:

 

To

 

run

 

the

 

engine

 

after

 

starting.

 

START:

 

To

 

start

 

the

 

engine

 

by

 

turning

 

the

 

starter

 

motor.

 

 

2.

 

The

 

fuel

 

valve

 

is

 

located

 

between

 

the

 

fuel

 

tank

 

and

 

carburetor.

 

When

 

the

 

valve

 

lever

 

to

 

the

 

ON

 

position,

 

fuel

 

is

 

allowed

 

to

 

flow

 

from

 

the

 

fuel

 

tank

 

to

 

the

 

carburetor.

 

Be

 

sure

 

to

 

return

 

the

 

fuel

 

valve

 

lever

 

to

 

the

 

OFF

 

after

 

stopping

 

the

 

engine.

 

 
 

3.

 

 

To

 

start

 

a

 

cold

 

engine,

 

move

 

the

 

choke

 

lever

 

to

   

the

 

CLOSED

 

position.

 

To

 

restart

 

a

 

warm

 

engine,

 

leave

 

the

 

choke

 

lever

 

in

 

the

 

OPEN

 

position.

 

The

 

choke

 

lever

 

opens

 

and

 

close

 

the

 

choke

 

valve

 

in

 

the

 

carburetor.

 

 

The

 

CLOSED

 

position

 

enriches

 

the

 

fuel

 

mixture

 

for

 

starting

 

a

 

cold

 

engine.

 

 

The

 

OPEN

 

position

 

provides

 

the

 

correct

 

fuel

 

mixture

 

for

 

operation

 

after

 

starting,

 

and

 

for

 

 

Содержание SP3500WS

Страница 1: ...1 22 GASOLINE GENERATING SET web www superpowergenerator com E mail verahardworking hotmail com Owner s Manual...

Страница 2: ...s as needed 4 Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry and long hair can be caught in movi...

Страница 3: ...d It will do the job better and more safely at the rate for which it was intended Do not modify this generator and do not use this generator for a purpose for which it was not intended INSTALLATION PR...

Страница 4: ...gine Key can be removed inserted ON To run the engine after starting START To start the engine by turning the starter motor 2 The fuel valve is located between the fuel tank and carburetor When the va...

Страница 5: ...the starter motor Return the key to the ON position once the engine has started Do not use the starter for more than 5 seconds at a time If the engine fails to start release the switch and wait 10 sec...

Страница 6: ...close circuit breaker 2 Turn the engine switch to OFF position 3 Turn the fuel valve lever to the OFF position When the engine is not in use leave the fuel valve lever in the OFF position to prevent c...

Страница 7: ...jurisdiction for local codes or ordinances that apply to the intended use of the generator 2 Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a signific...

Страница 8: ...sure that the voltmeter indicates the specified voltage Do not exceed the current limit specified for any one receptacle If an overloaded circuit causes the AC circuit breaker to switch OFF reduce the...

Страница 9: ...l is a major factor affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended Check the oil level BEFORE EACH USE with the gen...

Страница 10: ...xtremely flammable and is explosive under certain conditions Refuel in a well ventilated area with the engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or...

Страница 11: ...cable end A battery can explode if you do not follow the correct procedure seriously injuring anyone nearby Keep all sparks open flames and smoking materials away from the battery 1 Connect the batter...

Страница 12: ...CE Periodic maintenance and adjustment is necessary to keep the generator in good operating condition Perform the service and inspection at the intervals shown in the maintenance schedule below Exhaus...

Страница 13: ...onged periods Although this is unlikely unless you hands used oil on a daily basis it is still advisable to thoroughly wash your hands with soap and water as soon as possible after handing used oil Pl...

Страница 14: ...the excess oil The engine will smoke during initial startup if too much oil is left in the air cleaner element 4 Reinstall the air cleaner element and the cover Fuel Sediment Cup Cleaning The sediment...

Страница 15: ...er engine operation the spark plug must be properly gapped and free of deposits If the engine has been running the muffler will be very hot Be careful not to touch the muffler 1 Remove the spark plug...

Страница 16: ...n improperly tightened spark plug can become very hot and could damage the engine Never use spark plugs which have an improper heat range Use only the recommended spark plugs or equivalent TRANSPORTIN...

Страница 17: ...y loosening the drain screw Drain the gasoline into a suitable container Gasoline is extremely flammable and is explosive under certain conditions Perform this task in a well ventilated area with the...

Страница 18: ...18 22...

Страница 19: ...may ignite 2 Remove the spark plug and install the spark plug in the plug cap YES 3 Set the plug side electrode on the cylinder head 4 Crank the engine sparks should jump across the gap NO To check 1...

Страница 20: ...cuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or equipment for any defects Take the generator to an authorized generator dealer Replace the electrical appliance or equi...

Страница 21: ...21 22 WIRING DIAGRAM Starting with hand or Electric start...

Страница 22: ...22 22 Starting with hand start...

Отзывы: