17 USER 

CHECKLIST 

 

 

ο

 

Check air openings are not restricted and will not be blocked off.  Adequate supply air is 
necessary for combustion, flue gas dilution and ventilation.  

ο

 

When the boiler has operated for several minutes, check for spillage at draft hood, venting 
ducts, and other areas susceptible to spillage.  

ο

 

Check externally the draft hood and vent system for soot, rust scale or corrosion.  Check for 
dislodged venting or possible leaks in venting ducts. 

ο

 

Visually inspect main burners and pilot to ensure proper flame operating characteristics and 
ignition/extinction is ok. 

ο

 

Visually check burners to see that they are not cracked or dislodged. 

ο

 

Check that gas piping is secured. Smell for gas leaks around boiler and gas piping 
connections. Gas leaks can also be checked for using a soap solution; do not use an open 
flame to check for leaks.  Note: Propane is heavier than air and pools in low areas in the event 
of a leak. 

ο

 

Visually inspect for leaks in the water piping and at water piping connections. 

ο

 

Circulating pumps used with hot water heating systems should be inspected for water leaks. 

ο

 

Check for weeping at pressure relief valve outlet during normal operation. 

ο

 

Listen for unusual audible sounds in the boiler. 

ο

 

Read temperature and pressure gauge.  Check with qualified installer or service agency to 
determine acceptable temperature and pressure range for your heating system.  

ο

 

Combustible materials, gasoline and other flammable vapors and liquids should not be stored 
in the area of the boiler.  

If any problems are identified during your inspection, contact a qualified service agency for 
corrective measures. 

Once every year

 at the beginning of the heating season: 

ο

 

Have a qualified service technician remove the draft hood from the boiler and inspect the 
flueways for the presence of soot or rust scale. The draft hood and smoke pipe connecting the 
draft hood to the flue must be inspected for rust or corrosion before replacing the draft hood.  The 
presence of soot, rust scale or corrosion indicates misadjustment. 

 

ο

 

Have a qualified service technician inspect the pilot burner and main burner.

 

ο

 

The qualified service technician should follow the "Maintenance Checklist" and other applicable 
safety information found in the 

Installation and Service Manual

.

 

 

Содержание AAA-3000-E

Страница 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depa...

Страница 2: ...the appliance and or equipment such that only one service switch services both the appliance and the carbon monoxide detector b Have battery back up power c Meet ANSI UL 2034 Standards and comply wit...

Страница 3: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department B Use only your hand to push in or turn the gas control knob Never use tools If the knob wi...

Страница 4: ...purged of air and power supply to control is the correct voltage If the pilot or main burners are not lit or the control system is locked out due to flame failure close the main and pilot gas shut of...

Страница 5: ...a clear and free from combustible materials gasoline and other flammable vapors and liquids Do not store anything against the boiler or allow dirt or debris to accumulate in the area immediately surro...

Страница 6: ...as exhaust venting considerations must conform to the applicable codes If any alteration of the air supply and venting system is required contact a qualified service agency The boiler room must never...

Страница 7: ...iately contact a qualified service agency for adjustment or corrective measures 13 BOILER WATER Avoid unnecessary replenishment of system water It can allow oxygen to enter the system and cause seriou...

Страница 8: ...ef valve Avoid contact with the hot water or steam discharged to prevent personal injury 15 BLOCKED VENT AND FLAME ROLL OUT SAFETY SWITCHES Applicable to all boilers with an input rating less than 300...

Страница 9: ...rculating pumps used with hot water heating systems should be inspected for water leaks Check for weeping at pressure relief valve outlet during normal operation Listen for unusual audible sounds in t...

Страница 10: ...MG SG AAA Series Boilers User s Information Manual 10 18 TYPICAL RESIDENTIAL BOILER COMPONENT LOCATIONS...

Страница 11: ...MG SG AAA Series Boilers User s Information Manual 11 19 TYPICAL COMMERCIAL BOILER COMPONENT LOCATIONS...

Страница 12: ...Combination Gas Valve 4 6 To Turn off Gas to the Boiler or Emergency Shut Off 5 7 Area around Boiler 5 8 Check for Gas Leaks 5 9 Corrosive Atmospheres 6 10 Air Supply for Combustion and Ventilation 6...

Отзывы: