6
The aerator cylinder can cause injuries!
Prior to rectifying faults , unplug from the mains and wait until the aerator cylinder has stopped.
Wear working gloves when rectifying faults.
If the aerator cylinder is in wear adjustment position 3 and is worn , the aerator cylinder must
be replaced.
1. Unscrew two screws
⑽
on the underside of the hosing.
2. Lift Scarifier blades cylinder
⑿
at an angle and pull away driver shaft.
3. Remove bearing shell
⑾
from the Scarifier blades cylinder
⑿
4. Push bearing shell
⑾
on to the new Scarifier blades cylinder
⑿
5. Push new aerator cylinder
⑿
on to the driver shaft in such a way that the pin
⒁
is inserted in
the gap in the drive shaft
⒂
6. Screw bearing shell
⑾
to the underside of the housing without tightening too much.
7. There is another aerator cylinder
⒀
for exchange.
Fig. 7
12
11
13
10
14
15