background image

6

TA44T  Temperature alarm base unit with wireless transmitter.
R10 

Remote alarm wireless receiver.

SPECIFICATIONS

Power  

12 V  Adapter 120 VAC with 6 ft. cable included 

Probe  

Precision Thermistor with 6 ft. cable (20540)

Alarm Adjustment Range   

-40°F to 160°F (-40° to 71°C) 

Temperature Accuracy 

+/- 2°F (+/- 1°C)

Temperature Units 

 °F or °C, User Selectable

Remote Connections  

Screw type,120VAC, 5 Amps.

Unit Operating Temperature Range 

-10°F to +130°F (-23°C to +54°C)

Mounting  

Flat Surface, external holes provided

Dimensions   

4.9” x 3.1” x 1.5” (12.4cm x 7.9cm x 3.8cm)

Case  

Hi Impact Thermoplastic

NOTE:

This equipment has been tested and found to comply with the limits for a class B digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is 
no guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is    
 connected.
• Consult the dealer or an experienced radio/TV technician for help.
The user is cautioned that changes or modifications not expressly approved by the party 
responsible for compliance could void the user’s authority to operate this equipment.

TA44 WARRANTY

LIMITED TO ONE YEAR FROM DATE OF PURCHASE

Sealed Unit Parts Co., Inc. warrants its products to be free from defects in materials and 
workmanship under normal use and service. Sealed Unit Parts Co., Inc. will repair or replace 
without charge any such products it finds to be so defective on its return to Sealed Unit Parts 
Co., Inc. The foregoing is in lieu of all other expressed or implied warranties, including those of 
merchantability or fitness for a particular purpose. The foregoing is also the purchaser’s sole 
remedy and is in lieu of all other guarantees, obligations or liabilities or any consequential or 
incidental damages attributable to negligence or strict liability.

TA44 Manual.indd   7

5/8/2012   4:39:17 PM

Distributed by MicroDAQ.com, Ltd.                   www.MicroDAQ.com                   (603) 746-5524

Содержание TA44

Страница 1: ...MOTE WIRELESS ALARM Sealed Unit Parts Co inc PO Box 21 2230 Landmark Place Allenwood NJ 08720 USA Phone 732 223 6644 Fax 732 223 1617 www supco com info supco com 19204 TA44 Manual indd 1 5 8 2012 4 39 15 PM Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524 ...

Страница 2: ...y its state as follows In delayed alarm state the ALARM icon and the Bell will flash In the alarm state the ALARM icon and the Bell will remain solid The Bell clapper will flash Audible alarm will sound and the N O relay contacts will close The unit will transmit an alarm code to the wireless receiver causing the remote receiver to activate its audible alarm If the Silence button is pressed during...

Страница 3: ...n the receiver should turn off When the R10 receiver sounds an alarm this alarm can be silenced by pressing the silence button on the receiver When the receiver received the No Alarm signal from the transmitter the silence state is reset and the receiver returns to normal operation SENSOR EXTENSION The TA44T sensor probe is designed to measure air temperature and may be mounted in any convenient l...

Страница 4: ...mote receiver audible alarm as outlined above in the INSTALLATION AND REMOTE ALARM OPERATION section Set the temperature alarm threshold to the temperature the TA44T must respond to using the Up and Down buttons Typical values will be between 35 to 45 degrees for a refrigerator and 0 to 15 degrees for a freezer The setting of this adjustment will depend on the type of protection the TA44T is being...

Страница 5: ... the terminal strip below the switches This is where sensor probe power supply and remote alarm are connected to the TA44T The TA44T comes from the factory with the power supply and sensor probe attached Note the 3 unused terminals on the right These are the relay contacts for use with external devices such as remote alarms or automatic dialers Since each installation has different requirements it...

Страница 6: ...er code follow the steps below 1 Make sure an alarm condition is not present If possible turn off any other TA44T transmitters operating at the location 2 On the R10 receiver press and hold the Silence button until the Power and Alarm indicators start to flash 3 Let go of the Silence button 4 On the TA44T transmitter press the SILENCE button for about 1 second and then release it The Power and Ala...

Страница 7: ...ff and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help The user is cautio...

Страница 8: ...30 Landmark Place Allenwood NJ 08720 USA Phone 732 223 6644 Fax 732 223 1617 www supco com info supco com REV 03162012 P N22147 TA44 Manual indd 8 5 8 2012 4 39 17 PM Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524 ...

Отзывы: