To change the alarm transmit code on the TA44T transmitter follow the steps below:
 

1. Make sure an alarm condition is not present.

 

2. Press and hold both the UP and DOWN buttons for about 5 seconds, until the unit    

 

 displays.

 

3. Let go of the buttons.  The unit displays Pr, indicating that a new, random, alarm  

 

 

  code has been programmed into the unit.

To restore the unit to the factory default code, follow the steps below.
 

1. Make sure an alarm condition is not present.

 

2. Press and hold both the UP and DOWN buttons for about 5 seconds, until the unit    

 

  displays  - - .

 

3. Continue holding the UP and DOWN buttons for 5 seconds more, until the unit 

 

  displays dF, indicating that factory default code has been restored.

 

4. Let go of the buttons.

Once the TA44T transmitter has been programmed with a new code, one or more R10
receivers have to be programmed with this code to receive the alarm message. 
To synchronize the R10 receiver code to the TA44T transmitter code follow the steps below.
 

1. Make sure an alarm condition is not present.  If possible, turn off any other TA44T    

 

  transmitters operating at the location.

 

2. On the R10 receiver, press and hold the Silence button until the Power and Alarm    

 

  indicators start to flash.

 

3. Let go of the Silence button.

 

4. On the TA44T transmitter press the SILENCE button  for about 1 second and then    

 

  release it.  The Power and Alarm indicators on the R10 should stop flashing and  

 

 

  the Alarm indicator will turn off.

The R10 receiver is now matched to the transmitter.  To test communication, press and hold 
the SILENCE button on the TA44T transmitter.  The R10 should sound an alarm.  Release the 
SILENCE button on the TA44T transmitter.  The R10 alarm should go off.   If the test has failed, 
repeat the synchronization procedure, from step 1.

TA44T  Temperature alarm base unit with wireless transmitter.
R10 

Remote alarm wireless receiver.

PART NUMBERS

SW25  25’ Extension Wire
SW50  50’ Extension Wire
SW75  75’ Extension Wire
SW100  100’ Extension Wire
ADTA 

Phone Dialer

ACCESSORIES 

TA44 Manual.indd   6

5/8/2012   4:39:17 PM

Distributed by MicroDAQ.com, Ltd.                   www.MicroDAQ.com                   (603) 746-5524

Содержание TA44

Страница 1: ...MOTE WIRELESS ALARM Sealed Unit Parts Co inc PO Box 21 2230 Landmark Place Allenwood NJ 08720 USA Phone 732 223 6644 Fax 732 223 1617 www supco com info supco com 19204 TA44 Manual indd 1 5 8 2012 4 39 15 PM Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524 ...

Страница 2: ...y its state as follows In delayed alarm state the ALARM icon and the Bell will flash In the alarm state the ALARM icon and the Bell will remain solid The Bell clapper will flash Audible alarm will sound and the N O relay contacts will close The unit will transmit an alarm code to the wireless receiver causing the remote receiver to activate its audible alarm If the Silence button is pressed during...

Страница 3: ...n the receiver should turn off When the R10 receiver sounds an alarm this alarm can be silenced by pressing the silence button on the receiver When the receiver received the No Alarm signal from the transmitter the silence state is reset and the receiver returns to normal operation SENSOR EXTENSION The TA44T sensor probe is designed to measure air temperature and may be mounted in any convenient l...

Страница 4: ...mote receiver audible alarm as outlined above in the INSTALLATION AND REMOTE ALARM OPERATION section Set the temperature alarm threshold to the temperature the TA44T must respond to using the Up and Down buttons Typical values will be between 35 to 45 degrees for a refrigerator and 0 to 15 degrees for a freezer The setting of this adjustment will depend on the type of protection the TA44T is being...

Страница 5: ... the terminal strip below the switches This is where sensor probe power supply and remote alarm are connected to the TA44T The TA44T comes from the factory with the power supply and sensor probe attached Note the 3 unused terminals on the right These are the relay contacts for use with external devices such as remote alarms or automatic dialers Since each installation has different requirements it...

Страница 6: ...er code follow the steps below 1 Make sure an alarm condition is not present If possible turn off any other TA44T transmitters operating at the location 2 On the R10 receiver press and hold the Silence button until the Power and Alarm indicators start to flash 3 Let go of the Silence button 4 On the TA44T transmitter press the SILENCE button for about 1 second and then release it The Power and Ala...

Страница 7: ...ff and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help The user is cautio...

Страница 8: ...30 Landmark Place Allenwood NJ 08720 USA Phone 732 223 6644 Fax 732 223 1617 www supco com info supco com REV 03162012 P N22147 TA44 Manual indd 8 5 8 2012 4 39 17 PM Distributed by MicroDAQ com Ltd www MicroDAQ com 603 746 5524 ...

Отзывы: