Sunx SL-CPCI Скачать руководство пользователя страница 1


INSTRUCTION MANUAL 

 

 

    Sensor & Wire-saving Link System S-LINK  Series

 

 

Compact PCI BUS  S-LINK CONTROL BOARD 

SL-CPCI 


 

 

 













 






 

KEEP AWAY FROM STATIC ELECTRICITY 

Содержание SL-CPCI

Страница 1: ...INSTRUCTION MANUAL Sensor Wire saving Link System S LINK Series Compact PCI BUS S LINK CONTROL BOARD SL CPCI KEEP AWAY FROM STATIC ELECTRICITY...

Страница 2: ...le signal transmission Synchronization Bit synchronization frame synchronization Protocol S LINK protocol Transmission speed 28 5kbps Transmission distance Signal main cable extendable up to 200m max...

Страница 3: ...er program before using this board Please download the driver program from our internet home page http www sunx co jp Driver program is available for DOS Windows 95 98 and Windows NT If you cannot acc...

Страница 4: ...as Do not use the product in places where the ambient temperature or the humidity exceeds the specifications TERMINAL Do not tighten the screws with a torque exceeding the specifications OTHERS S LINK...

Страница 5: ...r Black White Blue Brown Black White Blue Brown External power supply input Tightening torque of the terminal screws 0 5 to 0 6 N m Terminal block MSTB2 5 10 ST 5 08 Made by Phoenix Contact Notes 1 Do...

Страница 6: ...Error 4 abnormality using this as the basis Transmission indicator Green It blinks when communicating I O data with S LINK units Transmission blinking No transmission off Error indicator Red It glows...

Страница 7: ...stem set HML 1 7 Frame check Status Area HML 1 8 Number of S LINK I O units where Error 4 occurs HML 1 9 Number of connected S LINK I O units HML 1 A System address length HML 1 B Address of SL BS1A w...

Страница 8: ...otes 1 Output is maintained until overwritten with the next output data 2 In case output data is mistakenly written into an input unit the written data is ignored and new input data is set after 1 4 t...

Страница 9: ...it automatically returns to 0 after transmitting the output data to the S LINK output unit So transmission error of output data will be prevented if you write in the next output data after its return...

Страница 10: ...Bank change over response register has been changed over HML 1 6 System set It has the same operation as bit 6 system set button of HML 1 0 Flag When a number other than 00 is written the S LINK I O u...

Страница 11: ...stop address Connection address SL BS1A address bit Assignment bit Assignment 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 ON 1 Stop abnormal OFF 0 Operating 6 ON 1 Connected OFF 0 Not connected Note Not v...

Страница 12: ...S LINK http www s linksystem net...