![Sunx LS-400 SERIES Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/sunx/ls-400-series/ls-400-series_operation-manual_1401432024.webp)
4-6. Timer Setting Mode
OFF-delay
Without timer
ON-delay
ONE-SHOT
The current
timer operation
Press the
MODE key
3 times.
Turn the
Jog switch.
Turn the jog switch to obtain
the desired setting.
Press the
Jog switch.
In case of setting
OFF-delay timer
The digital display will quickly
blink to confirm the setting.
Press the
MODE key
3 times.
This mode sets the timer operation and timer period.
The factory setting is ‘Without timer’.
The setting can be selected from Without timer / OFF-delay / ON-delay / ONE-SHOT timer.
Timer period: Can be set to between approx. 1 to 9,999 ms in units of 1 ms.
* Select the output 1 and output 2 beforehand.
1
Press the [MODE key] 3 times to select the ‘timer setting
mode’.
3
Turn the [Jog switch] to obtain the desired setting for timer
operation.
* When using rising / trailing differential mode, the timer is
set automatically to ONE-SHOT timer.
* For products manufactured up until June 2004 (~ Lot No.:
4F
□
) timer modes other than ONE-SHOT timer cannot be
used in rising / trailing differential modes.
5
Set the timer period starting from the 1st digit.
Turn the
[
Jog switch] to set the timer period for the digit that
is blinking.
* The factory setting is ‘10 ms’.
* If you do not want to change the timer period, you can
press the MODE key to cancel the setting. (Timer
operation is enabled.)
6
When all digits have been set, if the jog switch is pressed,
the timer period that has been set will quickly blink (red) and
the timer period will be confirmed.
7
Press the [MODE key] 3 times, the amplifier will return to
‘RUN mode’ (normal sensing operation).
(
)
4
If the [Jog switch] is pressed, timer operation (green) will
quickly blink on the digital display and the selected ‘timer
operation’ will be confirmed.
The digital display will not blink (green) if the setting has
not been changed.
2
The current setting will be displayed.
If the [Jog switch] is turned, the digital display will blink.
* The factory setting is ‘Without timer’.
* If timer operation has already been set (except for Without
timer), the display moves to the timer period setting (
5
)
when you press the jog switch.
23