9
This heater is not equipped with a device to control the room
temperature. Do not use this heater in small rooms when they are
occupied by persons not capable of leaving the room on their
own, unless constant supervision is provided.
Technical Specification
Model
Electrical
Supply
Capaci
ty
(Watt)
G.W.
Weight
(kg)
Product
Dimensions
(mm)
Package
Dimension
s
(mm)
IP Level
RPH031HCWL
-15
220-240V~
50 Hz
1500 4.35
900*100*90
1000*160*
190
24
Installation
Hanging Installation
a)
Mark and drill 2 (
φ
8) holes
on the ceiling as per
diagram.
b)
Insert plastic plugs (#1—
2pcs) into the holes.
c)
Screws (#3—2pcs) go
through the mounting pole
(#2-1pc) and fasten on the
ceiling.
d)
Insert the hanging lines (#4—
2pcs) into the line holes(#A) of mounting pole (#2).Length can be
manually adjusted by pushing the switch of hole(#A)
e)
Clip the power cord on the cable clip(#B) of mounting pole (#2).
Wall/Ceiling Mounted Installation
a)
Mark and drill 4(
φ
8) holes on the wall or ceiling as per diagram.
b)
Insert plastic plugs (#1—4pcs) into the holes.
c)
Screws (#3—4pcs) go through the mounting bracket (#2-1pc) and
fasten on the wall or ceiling.
d)
Parallel insert the bracket (#2) into the sheet (#4) –-on the top of
the heater and fasten with screw (#5—1pc).
e)
Fasten the screw (#A) of the bracket (#2) after adjust the suitable
angle for using the heater.