![Sunways STT Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/sunways/stt-series/stt-series_user-manual_1401193021.webp)
40
41
※ 6.5 Grid Protection settings
This mode can be enabled via the configuration software.It is enabled by default in some
regions, such as AU market. For information on how to change default setpoints please
contact Sunways Technical Support at [email protected]. User have access to
view the grid protection status in Sunways Portal APP. Please refer to bellow steps.
6.6 Fixed power factor setting
Please set “Power Factor” under the menu “Power Factor” in “Advanced Settings”.
Please follow this flow chart to set”Power Factor”:
The “Power Factor” settings are password protected. User should be able to view but not
edit. If you are installer, please contact importer for password. If there are any problems
in the installation process, please call Sunways service telephone at +86400-9922-958 or
email Sunways at [email protected] for consultation.
6.4.1 Power derating for voltage variation (Volt-Watt mode)
This mode can be enabled via the configuration software.It is enabled by default in some
regions, such as AU market. For information on how to change default setpoints please
contact Sunways Technical Support at [email protected].
6.4.2 Reactive power regulation for voltage variation (Volt-VAr mode)
This mode can be enabled via the configuration software.It is enabled by default in some
regions, such as AU market. For information on how to change default setpoints please
contact Sunways Technical Support at [email protected].
6.4.3 Reactive power mode
This mode can be enabled via the configuration software.It is enabled by default in some
regions, such as AU market. For information on how to change default setpoints please
contact Sunways Technical Support at [email protected].
※ 6.4 Power Quality Response Modes
Through the host computer software, set the ON/OFF state of the power quality response
mode to enable/disable this function. The default for this function in Australia is the ON
state. User have access to view the power quality response moude status in Sunways
Portal APP. Please refer to bellow steps.
6 General Operation
6 General Operation
Me
How to View
Steps In Sunways Portal APP
Device
Management
Device List
Protection
Parameters
…
Parameter
Settings
How to View
Steps In Sunways Portal APP
Me
Device
Management
Device List
Power
Control
Grid
Parameters
…
Parameter
Settings
Main
Window
Advanvced
Settings
Password
Setting
OK
Verified
OK
Power
Factor
Setting
Short press(1s), switch window
Long press(3s), enter the lower menu