5  Start and Stop

5 Start and Stop

※  5.1 Start the Inverter

When starting the inverter, follow these steps:
① Turn on the AC breaker first (close the AC circuit breaker).
② Turn on the DC switch in the bottom. If the PV string voltage higher than the inverter 
start-up voltage, the inverter will start.
③ When both AC and DC power supply are normal, the inverter is ready to start. The 
inverter will initiate checking its internal parameters and grid parameters, if it is within 
the range, the green light on the left side of the screen begins to flash, and the “Waiting” 
message will be displayed on the OLED display.
④ After self-checking completed, the inverter will start generating electricity, the green 
light will remain on, and the OLED display will display real-time power information.

※  5.2 Stop the Inverter

When turning off the inverter, please follow the steps below: 
① Turn off the AC breaker first.
② Wait 30 seconds and then turn the DC switch to the “OFF” position. At this time, 
there is remaining power in the inverter capacitor. Wait for 5 minutes until the inverter is 
completely de-energized before conducting any work on the inverter.
③ Disconnect the AC and DC cables.

6 General Operation

※  6.1 Display Operation

When the inverter is turned on, the following interfaces will be displayed on the OLED 
display, and the OLED display allows the user to check various operation information and 
to modify the settings of the inverter. Please refer to the following display operation flow 
for details:

6  General Operation

6.1.1 Main Window and General Setting

Short press(1s), switch window
Long press(3s), enter the lower menu

Setting

Setting

Setting

Setting

Main Window

Waiting

Normal

Checking

Fault info

Firmware

Updating

PV Voltage

PV Current

Grid Voltage

Grid Current

Grid Freq

Re-

Connect

Sys 

CtrlMode

Time Set

Modbus

Addr

Setting

Setting

Setting

LAN 

setting

WIFI 

setting

RSSI

Not WiFi/LAN

E-Day

CT Ratio

OverLoad 

(AU)

Language 

Set

E-Total

Grid Connect 

Type Set

Power 

Rate Limit

Export Limit 

On/Off 

XXX%

H-Total

Power 

Factor

Power Rate 

Limit 

XXX%Pn/min

Model

Name

Feed in 

Grid

Generation 

Limit

XXX%

General

Settings

Export 

Limit

Advanvced

Settings

Safety 

Set

Setting

Setting

Setting

Setting

Setting

Setting

Setting

OR

OR

SN/FM

Version

System 

Info

Error 

Message

Fault Info

Generation 

Limit

Содержание STT Series

Страница 1: ...S U N W A Y S T E C H N O L O G I E S C O LT D Grid connected Inverter STT 4 25KTL User Manual AU...

Страница 2: ...Connection 24 4 5 Monitoring Device Installation 31 4 6 Meter RS485 DRED Connection 32 5 Start and Stop 36 5 1 Start the Inverter 36 5 2 Stop the Inverter 36 6 General Operation 37 6 1 Display Operati...

Страница 3: ...this document do not constitute any express or implied guarantee 1 Preface 1 1 Overview This manual is an integral part of Sunways STT 4 25kW series three phase inverters hereinafter referred to as th...

Страница 4: ...led in a high traffic area where the fault is likely to be seen 2 2 Statement Sunways Technologies Co Ltd has the right not to undertake quality assurance in any of the following circumstances Damages...

Страница 5: ...l on the Inverter nameplate Inverter status indicator Inverter running indicator Grounding symbol the inverter casing needs to be properly grounded The inverter cannot be disposed of with household wa...

Страница 6: ...ries inverter includes 20 models which are listed below STT 4KTL STT 5KTL STT 6KTL STT 8KTL STT 10KTL STT 12KTL STT 15KTL STT 17KTL STT 20KTL STT 25KTL STT 4KTL P STT 5KTL P STT 6KTL P STT 8KTL P STT...

Страница 7: ...erter must be stored in its original packaging The storage temperature and humidity should be in the range of 30 and 60 and less than 90 respectively If a batch of inverters needs to be stored the hei...

Страница 8: ...r faults detected specific fault information can be viewed from the display Off The inverter is running normally Slow flashing The monitoring device is not connected to the router or is not connected...

Страница 9: ...e 1 Optional AC Terminal 1 Ground Terminal 1 6Pin Terminal 1 Note Export limitation control version 2pcs RS485 and DRED version 1 pcs This connector already pre installed inside the inverter STT 4 12k...

Страница 10: ...inverter at eye level for easy inspection of screen data and further maintenance The ambient temperature of the inverter installation location should be between 30 and 60 The surface temperature of th...

Страница 11: ...ate in the accessory bag then fix the L shaped plate to the mounting bracket Figure 4 6 Bracket assembly Use an electrical driller with 10mm diameter bit to drill 5 holes in the wall with 80mm depth W...

Страница 12: ...l to the grounding hole in the lower right side of the inverter as shown in Figure 4 9 The cross sectional area of the external grounding cable is 4mm2 Danger Do not connect the N wire as a protective...

Страница 13: ...pole of the PV string otherwise it will cause serious damage to the inverter Warning Static may cause damage to the electronic components of the inverter Anti static measures should be taken during in...

Страница 14: ...er grid make sure that the power grid voltage and frequency meet the requirements of the inverter See technical parameters for details All Sunways inverters incorporate internal RCD Residual Current D...

Страница 15: ...ve wires into the appropriate hole of the terminal head by following the rules yellow green wire to PE port red or brown fire wires to L ports no requests for the sequence of three fire wires and blue...

Страница 16: ...The 4G and GPRS version module does not need to be configured 2 The WiFi version module needs to be configured to the router for the first installation If the router name or password are changed the W...

Страница 17: ...ter with 3CTs to activate the Export Limitation control function on Sunways STT series inverter 1 RS485 A 2 RS485 B 3 PE NULL Port 2 Export limitation control RS485 DRED version with this port ln case...

Страница 18: ...oss sectional area of 0 75 1 5mm and an outer diameter of 5mm 10mm RS485 cable requirements Shielded twisted pair cable or shielded twisted Ethernet cable 4 6 3 Export limitation control or generation...

Страница 19: ...es until the inverter is completely de energized before conducting any work on the inverter Disconnect the AC and DC cables 6 General Operation 6 1 Display Operation When the inverter is turned on the...

Страница 20: ...the residencial three phase solar system is 15kVA in most of the states in Australia Check the local DNSPs or authorities if they allow AC output more than 15kVA Note Advanced settings can only be cha...

Страница 21: ...s tech com 6 4 2 Reactive power regulation for voltage variation Volt VAr mode This mode can be enabled via the configuration software It is enabled by default in some regions such as AU market For in...

Страница 22: ...mit in Advanced Settings Please follow this flow chart to set Export Limit The Export Limit settings are password protected User should be able to view but not edit the Export Limit If you are install...

Страница 23: ...ation Limit settings are password protected User should be able to view but not edit the Generation Limit If you are installer please contact importer for password If there are any problems in the ins...

Страница 24: ...icker AC cable if that is the case 7 Troubleshooting Error Message Description Troubleshooting Grid Frequency Fault Grid over frequency or underfrequency the grid frequency is higher or lower than the...

Страница 25: ...ult AC transducer anomaly Restart the inverter wait a moment for inverter recovery If the fault occurs repeatedly please contact Sunways Error Message Description Troubleshooting Relay Check Fail Self...

Страница 26: ...an the air inlet and outlet if necessary Six months to a year it d e p e n d s o n t h e d u s t contents in air 7 2 PV System for Ground Faults If ground fault occurs the inverter will beep the red L...

Страница 27: ...RD1699 NBR16149 IEC61727 IEC60068 IEC61683 EN50549 EN61000 8 Technical Parameters Model STT 6KTL STT 6KTL P STT 8KTL STT 8KTL P Input Start up Voltage V 200 180 200 180 Max DC Input Voltage V 1 100 1...

Страница 28: ...BR16149 IEC61727 IEC60068 IEC61683 EN50549 EN61000 Model STT 10KTL STT 10KTL P STT 12KTL STT 12KTL P Input Start up Voltage V 200 180 200 180 Max DC Input Voltage V 1 100 1 100 1 100 1 100 Rated DC In...

Страница 29: ...99 NBR16149 IEC61727 IEC60068 IEC61683 EN50549 EN61000 Model STT 15KTL STT 15KTL P STT 17KTL STT 17KTL P Input Start up Voltage V 200 180 200 180 Max DC Input Voltage V 1 100 1 100 1 100 1 100 Rated D...

Страница 30: ...1699 NBR16149 IEC61727 IEC60068 IEC61683 EN50549 EN61000 Model STT 20KTL STT 20KTL P STT 25KTL STT 25KTL P Input Start up Voltage V 200 180 200 180 Max DC Input Voltage V 1 100 1 100 1 100 1 100 Rated...

Страница 31: ...grated AC Short circuit Protection Integrated AC Over voltage Protection Integrated General Data Dimensions mm 550W 410H 175D Weight kg 25 29 25 29 Protection Degree IP65 Self consumption at Night W 1...

Страница 32: ...S11 00030 01 No 1 Second Road Green Industrial Zone Chongshou Town Cixi City ZheJiang Province PRC www sunways tech com service sunways tech com...

Отзывы: