background image

 

5 of 32 

© 2015 Watts Water Technologies

Installation must be performed by qualified personnel, in accordance with local codes and 

standards. A licensed electrician is recommended.

Phase 1 - Preparations

ALWAYS

  pay close attention to voltage and amperage requirements of the breaker, the 

thermostat, and the TapeMat. For instance, do not supply 240 VAC power to 120 

VAC TapeMat as damage will result.

ALWAYS

  make sure all electrical work is done by qualified persons in accordance with local 

building and electrical codes, Section 62 of the Canadian Electrical Code (CEC) 

Part I, and the National Electrical Code (NEC), especially Article 424.

ALWAYS

  use copper only as supply conductors to the thermostat. 

Do not use aluminum.

ALWAYS

  seek help if a problem arises. If ever in doubt about the correct installation procedure 

to follow, or if the product appears to be damaged, the factory must be called before 

proceeding with the installation.

Before installing TapeMat, make sure to fully inspect the products and carefully plan the site.

Items Needed

Materials:

• SunStat thermostat control with floor sensor. 
• SunStat Relay control (if required)
• Control electrical box (UL Listed, extra deep, see control instructions for size and type required)
• Junction electric box (if required, see Step 2.2)
• Wire nuts (Must be UL Listed and proper size)
• Flexible or rigid conduit (if required, see Step 2.4, must be UL Listed and proper size)
• 12-gauge or 14-gauge electrical wiring cable (consult local code)
• Nail plate (see Step 3.8)

Tools:

• Digital multi-meter for ohms testing; must read up to 20,000 ohms to measure sensor
• Drill with 1/2" & 3/4" bits
• Hammer and chisel
• Hot glue gun and hot glue (craft grade)
• Wire strippers
• Phillips screwdriver
• Fish tape
• Hole saw
• Floor covering installation tools

Floor sensor is  

included in the 

SunStat thermostat 

packaging. This must 

be installed in the 

floor with the mat.

Содержание TapeMat C12 series

Страница 1: ...are local codes may require this product and or the thermostatic control to be installed or connected by an electrician Please leave this manual with the end user Includes Custom TapeMat and ShowerMat...

Страница 2: ...6 Application Indoor floor heating only X on the nameplate label indicates CUL Listing for this application Suitable for installation in a shower area see Step 3 10 for restrictions W on the nameplate...

Страница 3: ...or or moderate injury This symbol identifies practices actions or failure to act which could result in property damage or damage to the equipment Table of Contents Important Safety Information 3 Phase...

Страница 4: ...g NEVER forget to install the floor sensor included with the thermostat NEVER install TapeMat in any walls or over walls or partitions that extend to the ceiling NEVER install mats under cabinets or o...

Страница 5: ...product appears to be damaged the factory must be called before proceeding with the installation Before installing TapeMat make sure to fully inspect the products and carefully plan the site Items Nee...

Страница 6: ...40 2 x 20 12002024 4 0 25 32 45 2 x 22 6 12002224 4 5 22 28 50 2 x 25 12002524 5 0 20 26 60 2 x 30 12003024 6 0 17 21 70 2 x 35 12003524 7 0 14 18 80 2 x 40 12004024 8 0 12 16 90 2 x 45 12004524 9 0 1...

Страница 7: ...9 C 8 000 ohms Table 3 Floor Sensor Resistance Values STEP 1 3 Use a digital multi meter set to the 200 or 2000 2k range to measure the resistance between the conductors of the mat power leads Record...

Страница 8: ...0VAC Sensor wire AFTER MAT AND SENSOR ARE FASTENED TO FLOOR OHMS Mat black to white black to blue for 240VAC Mat black to ground Mat white to ground blue to ground for 240VAC Sensor wire AFTER FLOOR C...

Страница 9: ...ons included with the SunStat for complete information on location and wiring The thermostat must be located at least 4 feet 1 2 meters away from shower openings to avoid being exposed to water or tou...

Страница 10: ...m plate up to the electrical box For multiple power leads multiple mats install 3 4 conduit Thermostat Sensor The SunStat Control sensor can be installed with or without electrical conduit depending o...

Страница 11: ...to reach the control location it may be possible to cut the mat mesh and pull loose the length of heating wire needed It is acceptable to run the power lead several feet in the floor area and embed i...

Страница 12: ...6 from a toilet wax ring It may be installed closer to walls if necessary but make sure the heating wire will not be located underneath finish trim Install in line with vanity and counter areas Instal...

Страница 13: ...Roll over Installing in front of cabinets and toilets Install mat right up to the face of the cabinet as shown above Mat can be installed under tile to within 6 from the wax ring and can slightly unde...

Страница 14: ...tar DO NOT staple or apply tape over the heating wire Damage can result DO NOT use nails duct tape other types of tape or other unapproved fasteners to hold the heating wire or mesh in place Damage ca...

Страница 15: ...t 1 into the mat area halfway between the heating wires and secure it using hot glue Do not cross the heating wires It may be necessary to chisel a small section of the subfloor to accommodate the sen...

Страница 16: ...run the heating wire through a non masonry curb causing it to overheat 7 Embed mats in mortar and install only under tile stone brick or other masonry surface per this instruction manual 8 Never begin...

Страница 17: ...see their web site at www tile assn com When installing floor coverings other than tile or stone follow industry and or manufacturer s recommendations Ensure the mat is first covered with a layer of s...

Страница 18: ...ick according to manufacturer s specifications Fully embed the heating wire and splices so that no portion of these show Install floor covering after the mortar has cured Special Precautions Isolation...

Страница 19: ...rack isolation membrane Insulating barrier TapeMat Thin set or self leveling mortar bed Insulation per International Residential Code Chapter 11 Insulation per International Residential Code Chapter 1...

Страница 20: ...ing and heating panels contained below the floor Do not penetrate floor with nails screws or similar devices Nappe de chauffage de sol Avertissement Rique de choc lectrique C blage lectrique et nappes...

Страница 21: ...istance between two heating wires Electrical box Single gang Mud Ring if required Electrical conduit Sensor wire Mat power lead Mat Mesh Thin set thick set thin slab or self leveling mortar bed Tile s...

Страница 22: ...IOM WR TapeMat 1526 22 of 32 Appendix 90 Turn 90 Flip Roll over Turn 180 or Back to Back Turn Fill in Technique Types of turns...

Страница 23: ...23 of 32 2015 Watts Water Technologies Step by step layout for a typical bathroom 1 2 3 4 5 6 7 8...

Страница 24: ...One mat Toilet Shower Bath Tub Closet Vanity Control Install 4 6 from walls Install mats right up to the face of the cabinet The heat only conducts about 1 1 2 from the wire Install mats 6 away from...

Страница 25: ...Three mats Small bath layout One mat Front Entryway Doorway Doorway Control Sink Bath Tub Install mats right up to the face of the vanity The heat transfers only about 1 1 2 from the wire Control Inst...

Страница 26: ...ring approximately 20 from back wall Fill in triangular areas by removing wire from mat and securing with hot glue Toilet Control Do not begin the mat inside the shower area The controls should NEVER...

Страница 27: ...local inspector or the authority having jurisdiction Never install the mat in shower walls or any other walls Shower installation detail Locate power lead and factory connection to heating wire at lea...

Страница 28: ...m any electrical work unless qualified to do so Work should be done with great care and with power turned off to the circuit being worked on Follow all local building and electrical codes The thermost...

Страница 29: ...If it trips again check for a short circuit in the mat as detailed earlier in this manual If mat is damaged record resistance between all wires and contact the manufacturer If mat is not damaged repla...