V series (Vdx) - 1956 mm×992 mm×50 mm  (1930 mm×998mm×50 mm)  

No.16

Module

Optimum

Operating

Voltage

(Vmp) at

STC, (V dc)

Optimum

Operating

Current

(Imp) at

STC, (A dc)

Open

Circuit

Voltage

(Voc) at

STC, (V dc)

Short

Circuit

Current

(Isc) at

STC, (A dc)

Maximum

Power

(Pmax) at

STC, 

(Watts)

Maximum

System

Voltage

(IEC/UL)

Maximum

Series

Fuse

Rating

Superpoly STP310-24/Vd 

36.5

8.50

45.4

8.85

310

1000/600

20

Superpoly STP305-24/Vd 

36.3

8.41

45.3

8.74

305

1000/600

20

Superpoly STP300-24/Vd 

36.1

8.32

45.2

8.65

300

1000/600

20

Superpoly STP295-24/Vd 

35.7

8.27

45.1

8.57

295

1000/600

20

Superpoly STP290-24/Vd 

35.6

8.15

45.0

8.42

290

1000/600

20

Superpoly STP285-24/Vd

35.4

8.06

44.9

8.37

285

1000/600

20

Superpoly STP280-24/Vd

35.2

7.95

44.8

8.33

280

1000/600

20

STP310-24/Vd

36.5

8.50

45.4

8.85

310

1000/600

20

STP305-24/Vd

36.3

8.41

45.3

8.74

305

1000/600

20

STP300-24/Vd

36.1

8.32

45.2

8.65

300 

1000/600

20

STP295-24/Vd

35.7

8.27

45.1

8.57

295

1000/600

20

STP290-24/Vd

35.6

8.15

45.0

8.42

290

1000/600

20

STP285-24/Vd

35.4

8.06

44.9

8.37

285

1000/600

20

STP280-24/Vd

35.2

7.95

44.8

8.33

280

1000/600

20

STP275-24/Vd

35.1

7.84

44.7

8.26

275

1000/600

20

STP270-24/Vd

35.0

7.71

44.5

8.20

270

1000/600

20

STP260-24/Vd

34.8

7.47

44.0

8.09

260

1000/600

20

STP290-24/Vdx

35.6

8.15

45.0

8.42

290

1000/600

20

STP280-24/Vdx

35.2

7.95

44.8

8.33

280

1000/600

20

STP275-24/Vdx

35.1

7.84

44.7

8.26

275

1000/600

20

STP270-24/Vdx

35.0

7.71

44.5

8.20

270

1000/600

20

STP260-24/Vdx

34.8

7.47

44.0

8.09

260

1000/600

20

PLUTO295-Vdx

36.5

8.09

45.3

8.57

295

1000/600

20

PLUTO290-Vdx

36.3

7.99

45.1

8.52

290

1000/600

20

PLUTO285-Vdx

36.1

7.90

44.9

8.46

285

1000/600

20

PLUTO280-Vdx

35.5

7.89

44.4

8.41

280

1000/600

20

PLUTO310-Vdm

36.8

8.43

45.6

8.84

310

1000/600

20

PLUTO305-Vdm

36.7

8.32

45.5

8.72

305

1000/600

20

PLUTO300-Vdm

36.6

8.20

45.4

8.62

300

1000/600

20

PLUTO295-Vdm

36.5 

8.09

45.3

8.57

295

1000/600

20

PLUTO290-Vdm

36.3

7.99

45.1

8.52

290

1000/600

20

PLUTO285-Vdm

36.1

7.90

44.9

8.46

285

1000/600

20

PLUTO280-Vdm

35.5

7.89

44.4

8.41

280

1000/600

20

W series - 1640 mm×992 mm×35 mm

Module

Optimum

Operating

Voltage

(Vmp) at

STC, (V dc)

Optimum

Operating

Current
(Imp) at

STC, (A dc)

Open

Circuit

Voltage
(Voc) at

STC, (V dc)

Short

Circuit

Current

(Isc) at

STC, (A dc)

Maximum

Power

(Pmax) at

STC, 

(Watts)

Maximum

System

Voltage

(IEC/UL)

Maximum

Series

Fuse

Rating

STP260-20/Wde

30.9

8.42

37.7

8.89

260

1000/600

20

STP255-20/Wde

30.8

8.28

37.6

8.76

255

1000/600

20

STP250-20/Wde

30.7

8.15

37.4

8.63

250

1000/600

20

STP245-20/Wde

30.5

8.04

37.3

8.52

245

1000/600

20

STP240-20/Wde

30.2 

7.95

37.2

8.43

240

1000/600

20

STP235-20/Wde

30.2

7.79

37.0

8.35

235

1000/600

20

STP230-20/Wde

29.8

7.72

36.8

8.25

230

1000/600 

20

STP225-20/Wde

29.6

7.61

36.7

8.15 

225

1000/600

20

STP220-20/Wde

29.5

7.46

36.6

8.05

220 

1000/600

20

STP215-20/Wde

29.2

7.37

36.5

7.95

215

1000/600

20

STP210-20/Wde

29.0

7.25

36.4

7.86

210

1000/600

20

V series  - 1956 mm×992 mm×40 mm  

Module

Optimum

Operating

Voltage

(Vmp) at

STC, (V dc)

Optimum

Operating

Current

(Imp) at

STC, (A dc)

Open

Circuit

Voltage

(Voc) at

STC, (V dc)

Short

Circuit

Current

(Isc) at

STC, (A dc)

Maximum

Power

(Pmax) at

STC, 

(Watts)

Maximum

System

Voltage

(IEC/UL)

Maximum

Series

Fuse

Rating

Superpoly STP310-24/Ve 

36.5

8.50

45.4

8.85

310

1000/600

20

Superpoly STP305-24/Ve 

36.3

8.41

45.3

8.74

305

1000/600

20

Superpoly STP300-24/Ve 

36.1

8.32

45.2

8.65

300

1000/600

20

Superpoly STP295-24/Ve 

35.7

8.27

45.1

8.57

295

1000/600

20

Superpoly STP290-24/Ve 

35.6

8.15

45.0

8.42

290

1000/600

20

Superpoly STP285-24/Ve

35.4

8.06

44.9

8.37

285

1000/600

20

Superpoly STP280-24/Ve

35.2

7.95

44.8

8.33

280

1000/600

20

STP310-24/Ve

36.5

8.50

45.4

8.85

310

1000/600

20

STP305-24/Ve

36.3

8.41

45.3

8.74

305

1000/600

20

STP300-24/Ve

36.1

8.32

45.2

8.65

300 

1000/600

20

STP295-24/Ve

35.7

8.27

45.1

8.57

295

1000/600

20

STP290-24/Ve

35.6

8.15

45.0

8.42

290

1000/600

20

STP285-24/Ve

35.4

8.06

44.9

8.37

285

1000/600

20

STP280-24/Ve

35.2

7.95

44.8

8.33

280

1000/600

20

STP275-24/Ve

35.1

7.84

44.7

8.26

275

1000/600

20

STP270-24/Ve

35.0

7.71

44.5

8.20

270

1000/600

20

STP260-24/Ve

34.8

7.47

44.0

8.09

260

1000/600

20

Содержание PLTUO245-Wde

Страница 1: ...ww suntech power com Wuxi Suntech Power Co Ltd Address Changjiang South Road New District Wuxi China 214028 Customer Service Hot Line 86 400 8888 009 Fax 86 510 8534 3321 E mail services suntech power com Or please contact our local representatives details at www suntech power com ...

Страница 2: ...safety Handling safety Installation safety Fire safety 4 Product Identification 5 Mechanical Installation Selecting the location General installation Installation method Attachment guidelines 10 Electrical Installation General installation Grounding 12 Maintenance No 1 ...

Страница 3: ...s of Isc Voc and Pmax under standard test conditions irradiance of 1000 W m AM 1 5 spectrum and a cell temperature of 25 C 77 F Only use equipment connectors wiring and support frames suitable for solar electric systems Purpose of this guide Handling safety Do not lift the module by grasping the module s junction box or electrical leads Do not sit stand step or walk on any side of the module Do no...

Страница 4: ...ll void the warranty Fire Safety Consult your local authority for guidelines and requirements for building or structural fire safety Roof constructions and installations may affect the fire safety of a building improper installation may create hazards in the event of a fire Use components such as ground fault circuit breakers and fuses as required by local authority Do not use panels near equipmen...

Страница 5: ...missible loads and are not subject to excessive forces due to the thermal expansion of the support structures Refer to the following installation methods for more detailed information Mechanical Installation Installation methods Modules can be installed on the frame using mounting holes clamps or an insertion system Modules must be installed according to the following examples Not mounting the mod...

Страница 6: ... and two clamps at the center of each long frame Insertion system Insertion system Use an insertion system on a long frame 2400 Pa Load 2400 Pa Wind Load 2400 Pa Snow Load 3800 Pa Load 3800 Pa Wind Load 3800 Pa Snow Load 5400 Pa Load 5400 Pa Snow Load 3800 Pa Wind Load Mounting system Clamping system Attachment to the long frame Length Use four clamps Use four clamps Use six clamps Clamping system...

Страница 7: ...ircuit current The recommended cable is PV wire with a cross section of at least 4mm2 No 10 The loads of 2400 Pa 3800 Pa and 5400 Pa are under IEC standard The installation methods applicable for 5400 Pa are also relevant for 3800 Pa and 2400 Pa The installation methods applicable for 3800 Pa are also relevant for 2400 Pa The module clamps must not come into contact with the front glass or deform ...

Страница 8: ...egative system grounding may be required by local authorities and can therefore be recommended In practice Suntech has observed certain installations with a positive impact on system performance due to implementation of negative system grounding If grounding is required the grounding wire must be properly fastened to the module frame to assure adequate electrical connection Suntech recommends the ...

Страница 9: ...00 600 20 STP225 20 Wd 29 6 7 61 36 7 8 15 225 1000 600 20 STP220 20 Wd 29 5 7 46 36 6 8 05 220 1000 600 20 STP215 20 Wd 29 2 7 37 36 5 7 95 215 1000 600 20 STP210 20 Wd 29 0 7 25 36 4 7 86 210 1000 600 20 STP265S 20 Wd 31 0 8 55 37 8 9 01 265 1000 600 20 STP260S 20 Wd 30 9 8 42 37 7 8 89 260 1000 600 20 STP255S 20 Wd 30 8 8 28 37 6 8 76 255 1000 600 20 STP250S 20 Wd 30 7 8 15 37 4 8 63 250 1000 6...

Страница 10: ...1000 600 20 PLUTO285 Vdm 36 1 7 90 44 9 8 46 285 1000 600 20 PLUTO280 Vdm 35 5 7 89 44 4 8 41 280 1000 600 20 W series 1640 mm 992 mm 35 mm Module Optimum Operating Voltage Vmp at STC V dc Optimum Operating Current Imp at STC A dc Open Circuit Voltage Voc at STC V dc Short Circuit Current Isc at STC A dc Maximum Power Pmax at STC Watts Maximum System Voltage IEC UL Maximum Series Fuse Rating STP26...

Отзывы: