SunTech Oscar Express Remote Site Скачать руководство пользователя страница 25

25

Troubleshooting

The following sections address issues and situations that the central terminal or remote site may
encounter when conducting an ABP study or an attempted Express modem data transfer. The
table below covers issues when using AccuWin-Express for a modem data transfer while the
overview of quality and test codes describes issues specific to the Oscar 2 monitor itself. The
accompanying solutions will help guide you through solving these problems. 

Oscar Express modem data transfer troubleshooting 

Issue

Solution

Modem doesn’t power on

Check power cord connection. 

Check power button on rear of modem is depressed.

Oscar 2 monitor doesn’t power on
(LCD always blank)

Replace batteries.

No dial tone on combined data/voice
phone line (voice option 2)

Check phone line connections from wall jack to
modem.

Check phone line connection from phone to modem.

Auto-dial does not work or dials
wrong number.

Use phone to manually dial central terminal. 

Central terminal should check the remote site
information window for correct auto-dial number
settings.

If the Oscar 2 unit is at the central terminal, re-
assigning the monitor to the remote site with the
corrected auto-dial number in the remote site
information window will re-program the monitor
correctly.

To change the auto-dial number on an Oscar 2 unit at
a remote site, the central terminal must enter the
correct number in the Modem Data Transfer window.
The central terminal may have to enable this in the
Express > Settings > Options window.

Modem data transfer fails.

Check phone line connections between modem and
wall jack.

Check cable connections between the modem and the
Oscar 2 unit.

Check that the Oscar 2 unit is Express capable.
(Displays 

OE 

when turned on).

If using voice communication option 2, background
noise can interfere with the modem data transfer.
Using a mute button and minimizing background noise
will help alleviate this problem.

Disable call waiting if applicable.

Содержание Oscar Express Remote Site

Страница 1: ...Oscar Express Remote Site User s Guide...

Страница 2: ...2...

Страница 3: ...n 13 Specifications 14 Safety and Effectiveness 15 Warnings and Contraindications 15 Oscar 2 at a Glance 17 Preparing the Patient for Oscar 2 ABP Study 18 Oscar Express Data Transfer with Central Term...

Страница 4: ...ns with diagnosis and management of hypertension The data obtained from ambulatory blood pressure monitors is highly accurate and useful for managing a wide variety of hypertensive situations includin...

Страница 5: ...smission This eliminates the time and cost of mailing or transporting an ABP monitor between sites for remote data collection and ABP report generation Note Oscar Express is currently validated for us...

Страница 6: ...ata transmission is an available analog phone line The remote site manages the clinical process of data collection issuing the monitor to patients setting up the patients with the monitor and making s...

Страница 7: ...f items Your central terminal should have already set up your Oscar 2 monitor and programmed it for an ABP study thus making it ready for an immediate patient study To verify this turn on the monitor...

Страница 8: ...ient ABP data and re program for the next study the proper connections need to be made in order to successfully perform a modem data transfer 1 Plug Oscar 2 to modem cable into the 25 pin port on the...

Страница 9: ...ine as well a dual jack adapter is included to convert your wall jack into 2 jacks 4 Connect modem power cable to the modem and plug into to wall outlet The modem is now connected The final connection...

Страница 10: ...ta transfer with the remote site the central terminal operator needs to communicate with the remote site to Identify which remote site is about to send data Identify the remote user they are speaking...

Страница 11: ...ine connected to the modem is for data only The remote site makes a person to person call to the central terminal operator with the voice line and exchanges necessary information before performing a d...

Страница 12: ...ssary information to perform the data transfer When instructed by the central terminal the remote site begins the data transfer over the same phone line Once modem communication is complete the modem...

Страница 13: ...ed by the oscillometric method that senses pressure waves in the artery when occluded by pressure in the cuff Measurement of the frequency of the pressure waves also allows heart rate to be measured T...

Страница 14: ...battery powered Operating Conditions 10 C 50 F to 50 C 122 F 20 95 RH non condensing Power Two AA alkaline batteries or high capacity rechargeable batteries NiMH Calibration Minimally once every year...

Страница 15: ...not been established SunTech Medical Instruments Inc is responsible for the safety reliability and performance of its equipment under the following conditions Assembly operations extensions re adjust...

Страница 16: ...ed for analog phone lines ONLY Data transfers through office PBX or other digital phone systems are not expected to be compatible with the Express modem data transfer Precautions for Use Ensure pressu...

Страница 17: ...the remote site to the central terminal and can be programmed to automatically dial the central terminal Oscar Express enabled An Oscar 2 monitor displays an OE upon powering on to indicate the monit...

Страница 18: ...rinter Indicates the number of readings in memory Percentage Indicates what percentage of Express data transfer is complete Preparing the Patient for Oscar 2 ABP Study In order to accurately measure b...

Страница 19: ...the Oscar 2 into its pouch with the display showing through the window Fig 5 Attach the pouch to the patient using either the shoulder strap or belt depending on the patient s preference Fig 6 Ensure...

Страница 20: ...uff sleeve is directly over the brachial artery Fit the cuff snugly around the upper arm While sleeping the patient should make sure that the hose is not crimped The batteries can be replaced during a...

Страница 21: ...ode turn the monitor off and then power the monitor back on The first step in performing a data transfer is to call a central terminal operator to identify your remote site indicate you have patient d...

Страница 22: ...hile the central terminal operator can communicate to you the status of the data transfer over the voice line Step 4 Completing communication with Central Terminal When the data transfer is complete t...

Страница 23: ...Warning Any background noise during the data transfer can interfere with the modem transmission If the remote site phone has a mute button it should be used to minimize background noise from interferi...

Страница 24: ...protocol at any time and initiate a reading if you have programmed the Oscar 2 monitor to do so Indicates that the pressure to which the cuff inflated in the dynamic inflation mode may have been too...

Страница 25: ...ial does not work or dials wrong number Use phone to manually dial central terminal Central terminal should check the remote site information window for correct auto dial number settings If the Oscar...

Страница 26: ...ement time Check air hose connections and make certain cuff is tight 85 Reading Aborted blocked values or pneumatics Check air hose connections and make certain air tubing is not crimped 86 Reading Ab...

Страница 27: ...that would indicate that this reading is suspect Refer to the table above for detailed definitions of Test Codes LOH Dynamic pressure too low Pressure to which cuff inflated in the dynamic inflation...

Страница 28: ...dian and Latin American Headquarters and Service 507 Airport Boulevard Suite 117 Morrisville NC 27560 8200 Toll free USA and Canada 800 421 8626 Phone 919 654 2300 Fax 919 654 2301 www SunTechMed com...

Страница 29: ...lly inspect cables pneumatic hoses and the monitor case for cracks fraying or kinks DO NOT use the monitor if it shows any signs of damage Contact the SunTech service department Annual Maintenance It...

Страница 30: ...k the unit against the column every 50 mmHg from 250 to 50 mmHg and the unit should be within 2 0 mmHg If not the unit needs to be returned to the service department for recalibration or repair The Os...

Страница 31: ...98 0063 01 0 1 Orbit ABP cuff Adult 98 0063 02 1 1 Orbit ABP cuff Large Adult 98 0063 03 0 1 Oscar 2 Pouch 98 0032 00 1 1 Oscar 2 Strap 98 0036 00 1 1 Oscar 2 Belt 98 0037 00 1 1 Patient Diaries 82 00...

Страница 32: ...cted defect The instrument should be carefully packaged and shipped prepaid to SunTech Medical 507 Airport Boulevard Suite 117 Morrisville NC 27560 8200 Tel 1 800 421 8626 or 1 919 654 2300 Fax 1 919...

Страница 33: ...33 80 0031 00 Part 80 0031 00 Rev A...

Отзывы: