Error Messages

 

Msg. 

Icon 

Description 

Er00 

“PUMP ON” flashing 

Problem with pump or pump tube is kinked. 

Er01 

N/A 

Check coil temperature sensor at  the side  of 

coil and its sensor cable. 

Er02 

N/A 

Check ambient temperature sensor in the front 

of the coil and its senor cable. 

Er03 

N/A 

Check humidistat sensor in the front of the coil.   

Er04 

N/A 

Ambient temperature is too high. 

Note: Contact your local distributor for service. 

 
On/Off Indication Light: 

Color 

Status 

Description 

N/A   

Off 

Machine has been turned off.

 

Red   

On 

Machine has been turned on. 

Green 

On 

Machine start dehumidification.

 

 
WiFi Indication Light: 

Color 

Status 

Description 

Red 

Flash, 2 times per Sec. 

EZ mode WiFi connection 

Red 

Flash, 1 time per Sec. 

AP mode WiFi connection 

Red 

On 

EZ/AP WiFi Connection Failure 

Green 

Flash, 1 time per Sec. 

Connecting WiFi network. 

Green 

On 

WiFi Connection successful. 

Green 

Flash, 2 times per Sec. 

WiFi  Connection  Failure/  WiFi  pcb  is 

disconnected. 

 

Maintenance 

WARNING! 

Always  unplug  any  dehumidifier  before  performing  maintenance 

procedures. 

Before Each Use 

l

 

Inspect the electrical cord for damage. 

LCD Display – Cont. 

 

“TOTAL”  CLOCK.

  While  “TOTAL” 

CLOCK time is chosen, “TOTAL” wording 

in the square box will flash for 3 sec. The 

4  digits  show  how  many

  DAYS

  the 

machine has been used. 

 

 

 

 

“JOB”  CLOCK

.

 

While  “JOB”  CLOCK 

time  is  chosen,  “JOB”  wording  in  the 

square  box  will  flash  for  3  sec.  The  four 

digits  display  how  many 

HOURS  and 

MINUTES

  either  the  CURRENT  JOB  is 

running or the LAST JOB has been run. 

 

 

 

o

F”    TEMPERTURE.

 

While  “

o

F” 

TEMPERTURE  function  has  been 

chosen,  “

o

F”  wording  in  the  square  box 

will  flash  for  3  sec  and  3  digits  figures 

display  the  current 

ambient  “

o

F”   

temperature. 

 

 

o

C”    TEMPERTURE.

 

While  “

o

C”

 

TEMPERTURE  function  has  been 

chosen,  “

o

C”  wording  in  the  square  box 

will  flash  for  3  sec  and  2  digits  figures 

display  the  current  ambient  “

o

C” 

temperature. 

 
 

Содержание ST601 Pro

Страница 1: ...Suntec Industries H K Ltd Tel 852 8130 0676 Fax 852 8130 0671 URL www suntecind com READ AND STUDY MANUAL BEFORE USE LGR Mobile Dehumidifier 220 240V Model ST601 Pro ST1001 Pro OPERATING MANUAL...

Страница 2: ...e a risk of injury from electric shock l Do not use the adaptor l Do not operate the unit with a damaged power cable l Always operate the unit with an earthed plug and with an earthed supply l Extensi...

Страница 3: ...ack of the unit Plug it into a standard outlet with the correct voltage and amperage for the unit If the unit experiences a loss of power which can results from a power interruption and overheated Bef...

Страница 4: ...rain Hose Length 10m 10m Cable Length 8m 8m Height 840mm 840mm Width 500mm 500mm Depth 485mm 485mm Use Weight 40kg 50kg Specifications are subject to change without notice Some values are approximate...

Страница 5: ...gnal this problem by displaying ER00 l Inspect filter Look for accumulated dust and dirt that would restrict airflow through the filter into the unit If any is visible vacuum out the debris Do not was...

Страница 6: ...twork Green On WiFi Connection successful Green Flash 2 times per Sec WiFi Connection Failure WiFi pcb is disconnected Maintenance WARNING Always unplug any dehumidifier before performing maintenance...

Страница 7: ...releasing either the preset humidity or the timer can be adjusted continually Touch Pad Keys Cont START STOP Press the START STOP key to start or stop the dehumidification l When dehumidification star...