LCD Display – Cont. 

 

“CURRENT”  HUMIDITY.

 

When  the 

machine  is  turned  on,  the  default  display 

function  goes  to  “CURRENT”  HUMIDITY. 

“CURRENT” wording in the square  box will 

flash for 3 sec and 2 digits Relative Humidity 

figures display the current ambient humidity. 

 

 

 

“SET” 

HUMIDITY.

 

While 

“SET” 

HUMIDITY  function  is  chosen,  “SET” 

wording in the square box will flash for 3 sec 

and  the  bottom  2  digits  Relative  Humidity 

figures also flash continuously until the user 

set the desired humidity which is from 25% 

to  80%.  “- -  %RH” is the value beyond this 

range, 

which 

read 

as 

nonstop 

dehumidification. 

 

 

“TIMER”  CLOCK.

  While  “TIMER” 

CLOCK time is chosen, “TIMER” wording in 

the  square  box  will  flash  for  3  sec.  The 

bottom four digits show how many

 HOURS 

and MINUTES

 the “TIMER” is. In STANDBY 

mode,  the  four  digits  (-  -  :  -  -)  flash 

continuously until user sets the TIMER from 

00:10 to 23:50  hours. Once the “TIMER”  is 

set  and  machine  starts  running,  the  four 

digits  displays  remain  running  time  of  the 

current TIMER., “- - : - -” is the value beyond 

this  range,  which  read  as  nonstop 

dehumidification.   

l

 

Inspect pump tube.

 Make sure the pump tube is completely unwrapped 

and not kinked. Failure to do so can cause water to back up in the pump 

and  leak  out.  The  control  panel  may  signal  this  problem  by  displaying 

“ER00”

 

l

 

Inspect filter. 

Look for accumulated dust and dirt that would restrict airflow 

through the filter into the unit. If any is visible, vacuum out the debris. 

Do 

not wash the filter

, as it will reduce the effectiveness of the electrostatic 

material. 

Important: 

Replace the filter whenever 

l

 

It has been vacuumed clean 3 times. 

l

 

It has been used on a mold remediation job. 

Periodically Inspection (as needed) 

Make sure the unit is unplugged. Remove housing, in order to locate the coil, 

pump and drain hose. 

l

 

Check coil and clean visible dirty 

n

 

Vacuum both sides of the coils until clean. 

l

 

Check pump 

n

 

Inspect  and  clean the  pump  system regularly to maintain  effective 

operation.  Remove one  screw  to  open  up the  top  cover, and  then 

open  up  the  second cover.  Clean the float  shaft to make  sure the 

floating switch can operate smoothly. 

l

 

Check drain hose 

n

 

Look for obstructions. Disconnect and clear any debris present. 

 

Warranty 

SunTec warrants to the original purchaser that if, within a period of 12 months 

from  the  date  of  purchase,  this  equipment  is  found  to  be  defective  either  in 

original  materials  or  workmanship  (excluding  normal  usage  wear  and/or 

mishandling  or  abuse)  the  faulty  part  will  be  replaced  free  of  charge  upon 

presentation of the appropriate evidence, provided the unit is returned to the 

original supplier. Shipping expenses are not covered under the warranty.

 

 

Содержание ST601 Pro

Страница 1: ...Suntec Industries H K Ltd Tel 852 8130 0676 Fax 852 8130 0671 URL www suntecind com READ AND STUDY MANUAL BEFORE USE LGR Mobile Dehumidifier 220 240V Model ST601 Pro ST1001 Pro OPERATING MANUAL...

Страница 2: ...e a risk of injury from electric shock l Do not use the adaptor l Do not operate the unit with a damaged power cable l Always operate the unit with an earthed plug and with an earthed supply l Extensi...

Страница 3: ...ack of the unit Plug it into a standard outlet with the correct voltage and amperage for the unit If the unit experiences a loss of power which can results from a power interruption and overheated Bef...

Страница 4: ...rain Hose Length 10m 10m Cable Length 8m 8m Height 840mm 840mm Width 500mm 500mm Depth 485mm 485mm Use Weight 40kg 50kg Specifications are subject to change without notice Some values are approximate...

Страница 5: ...gnal this problem by displaying ER00 l Inspect filter Look for accumulated dust and dirt that would restrict airflow through the filter into the unit If any is visible vacuum out the debris Do not was...

Страница 6: ...twork Green On WiFi Connection successful Green Flash 2 times per Sec WiFi Connection Failure WiFi pcb is disconnected Maintenance WARNING Always unplug any dehumidifier before performing maintenance...

Страница 7: ...releasing either the preset humidity or the timer can be adjusted continually Touch Pad Keys Cont START STOP Press the START STOP key to start or stop the dehumidification l When dehumidification star...