TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL

TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL

depending  on  the  configured 

intervals;

3) controls  the  operation  of  the 

circulation  pump  of  the  central 

heating;

4) controls the operation of the pump of 

the domestic hot water;

5) option  for  control  by  room 

thermostat;

6) timer;

• 

Photo-sensor

 - monitors the power of 

the burner flame

• 

Internal auger

• 

Dry contactless resistance heater 

assuring ignition of fuel

• 

Innovative  cleaning  system

 of the 

combustion chamber

• 

Air  feed  fan

,  step-regulated

  (from  0% 

to 100 %).

2.2. Burner safety devices

• 

Thermostatic  protection  (80°С)

. The 

thermostatic protection is fitted on the 

feeder chute. When the surface of the 

feeder chute reaches 80°С, the control 

stops the feeding of pellets into the 

burner and signals for fault.

Temperature  safety  valve 

with sensor 

on screw mechanism.  Temperature 

safety valve is connected to a water 

tank.

• 

Fuse

. In case of electrical fault in the 

system of the burner (short circuit, high 

current, etc.), the overload is borne by 

the  electrical  fuse  fitted  on  the  main 

control panel of the burner 

(10 А)

.

• 

Power  interruption

. In case of power 

interruption, all parameter settings are 

stored in the memory of the controller. 

Upon the subsequent restart of the 

burner,  the  controller  resumes  the 

execution  of  the  program  from  the 

point  when  the  power  interruption 

occurred.

• 

STB - 

emergency  thermostat  (with 

probe inserted into the socket of the 

boiler).  When  boiler  temperature  is 

increasing  above  100°C,  the 

STB

 – 

thermostat  stop  the  operation  of  feed 

screw.

3. FUEL

All pellets are biomass manufactured 

from common low-growing plants and 

trees. The most common household type 

pellets are made of sawdust and milled 

wood chippings which are waste material 

from  wood  used  in  the  production  of 

logs, furniture and other products. Wood 

is the richest raw material which does 

not  have  any  impact  on  the  production 

costs of food products or ethyl alcohol 

(ethanol). The raw material is processed 

under high-pressure and temperature 

and is pressed to produce small-size 

cylindrical  pellets.  The  production 

process  may  utilize  soft  wood  material 

(such as softwood, pine), hardwood (oak) 

as well as recycled waste wood. Wood 

pellets are produced in hammer mills or 

wood pellet plants.

Advantages of wood pellets:

Convenient  storage.

 Pellet bags can be 

stored  on  a  small  area  in  a  dry  garage, 

basement, service room or shed.

Easy  loading.

 In most cases the boiler 

hopper needs loading only once a week – 

this depends on the hopper capacity.

Better control of fuel quantity.

 The small 

size of the pellets allows for precise fuel 

feeding.  On  the  other  hand,  the  supply 

of  air  for  reaching  optimal  combustion 

efficiency  is  easier  to  adjust  since  the 

fuel quantity in the combustion chamber 

remains constant and predictable.

Содержание BURNiT Pell 300 Mega

Страница 1: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL FOR AUTHORIZED INSTALLER SERVICE SHOP PELLET BURNER Pell Mega series Version i2 2 EN ...

Страница 2: ......

Страница 3: ...urner to pellet auger and fuel hopper 10 7 2 Connecting the burner to the mains power supply 11 7 3 Trouble shooting 13 8 OPERATION OF BURNER BURNER 14 8 1 Ignition 14 8 2 Combustion 14 8 3 Automatic cleaning system 14 8 4 Requirements for an authorized installer service 14 8 5 Important recommendation for long lasting and correct operation of the burner 14 9 CONTROLLER UNIT 15 9 1 Controller view...

Страница 4: ...per operation of the product 1 2 1 Instructions to boiler installer During installation and operation the country specific requirements and regulations must be observed local construction regulations on installation air supply and exhaust gas extraction as well as chimney connection regulations and norms concerning the fitting of the heating installation with safety devices i Use only original BUR...

Страница 5: ...the burner down and clean it Unattended children must not be allowed access to premises with running pellet burner inside It is mandatory to assure a backup power generator of corresponding rated power see 12 2 Safety rules for user operation Operate the pellet burner on recommended fuel only and to that end you must regularly inspect the boiler room Do not use flammable liquids for ignition or in...

Страница 6: ...omatic cleaning function and internal pellet auger ensure the automated operation of the burner and optimal burning of the fuel 2 1 Design The burner is made of high quality stainless steel able to withstand temperatures of up to 1150 С The burner must be installed on a heating boiler The burner consists of two parts combustion chamber tube and external tube On the upper part of the burner there i...

Страница 7: ...rom the point when the power interruption occurred STB emergency thermostat with probe inserted into the socket of the boiler When boiler temperature is increasing above 100 C the STB thermostat stop the operation of feed screw 3 FUEL All pellets are biomass manufactured from common low growing plants and trees The most common household type pellets are made of sawdust and milled wood chippings wh...

Страница 8: ...lated place The optimal pellet ash content is 1 This also provides for less frequent cleaning intervals for the burner The table below contains the parameters which we recommend that you take into consideration when choosing fuel for your Pell Mega burner 4 TRANSPORTATION OF THE PELLET BURNER When loading transporting and unloading of the device appropriate safety equipment must be used in accorda...

Страница 9: ...t have direct contact with the ground placed on pallets maximum two tiers and in their original packaging The storage period is not more than 2 years from date of manufacture It is recommended that every burner is tested before installation Quality and safety of the burner must be confirmed by a test mentioned in the warranty card 7 MOUNTING OF THE BURNER Mounting installation and setup of burner ...

Страница 10: ...dmium content mg kg 2 0 5 0 5 0 5 Mercury content mg kg 2 0 1 0 1 0 1 Plumbum content mg kg 2 10 10 10 Nickel content mg kg 2 10 10 10 Zinc content mg kg 2 100 100 100 1 Not more than 1 of the pellets may be longer than 40 mm max Length 45 mm 2 Dry weight 3 Particles 3 15 Mm particulate matter before handing over the goods 4 Measurements with lignotester limit value 97 7 by weight 7 1 Pellet burne...

Страница 11: ...re it is unplugged during the storms The boiler must be connected to a 220V 50Hz mains using power plug 3 meters long bound to the burner Create tight connection with the electrical mains which complies with the local regulations Diagram 4 Wiring diagram Connection of internal devices to the burner connector FM FSG SF SB PH PWH IGN FC RT PS RB B WH PT OD 1 2 5 7 8 9 10 34 11 12 MAIN FAN Electric m...

Страница 12: ...y 220 V N L CH Pump 220 V N L DHW Pump 220 V N L Fuel Feeder Boiler Sensor Sensor Sensor Sensor STB Thermostat Inputs Group 1 RT Room thermostat PS Photo sensor RB Temperature sensor at the top of the buffer B Boiler Group 2 WH Water heater PT Temperature sensor at the bottom of the buffer OD Sensor reverse burning Outputs FM Fan main FSG Fan smoke gases SF Screw fuel SB Screw burner PH Pump heati...

Страница 13: ...he manual 3 2 Low performance of the automatic cleaning function 3 2 Increase turn on frequency of the automatic cleaning function 3 3 Improper setting of fuel air mixture 3 3 Adjust using gas analyzer 4 Smoke in the pellet hopper 4 1 Poor chimney draught or high internal resistance of the boiler combustion chamber 4 1 Immediately consult your installer about the problem 4 2 Blockage of burner com...

Страница 14: ...d rate thus removing all residues ash noncombustible inclusions etc built up into the combustion chamber of the boiler These automatic cleaning cycles continue depending on the parameters set by the command block The cleaning cycles can be additionally adjusted as well as their repeat rate depending on the load of the burner 8 4 Installer prescriptions regarding burner servicing and maintenance Be...

Страница 15: ...he combustion chamber housing 9 CONTROL UNIT 9 1 Controller view Explanation of buttons and indicators LCD screen The controller screen displays the information for the operation of the facility Explanation of buttons Button F function button Apply for exit of the current menu taking back to main screen burner transfer from one condition to another Button Enter apply for switching from one paramet...

Страница 16: ...t This symbol means Suspend mode of boiler The notice Hi appearance on the screen where the boiler temperature is displayed means that the measured Boiler body temperature is above 120 C Flashing and beeping alarm is activated When the issue is corrected notification can be deleted When disconnect the boiler from electrical supply for few seconds and then switch on it again boiler goes back to nor...

Страница 17: ...burns 5 min at max power followed by transer to power level 2 After 5 min the burner transfers to power level 1 and after 5 min transfers in Suspend mode When there is no signal from room termostat or there is non fullfilled requirement for DHW the burner will fire up In CH DHW mode when DHW Domestic hot water requirement is fullfilled and there is a signal from room termostat the burner burns 5 m...

Страница 18: ...ll restart once the water temperature inside the DHW tank drops by 5 C In this way the water temperature inside the DHW tank will be kept at a hysteresis of 5 C i e the water temperature will be between 70 C and 75 C Use UP and DOWN arrow keys in Set Time menu to set the unit s built in timer clock Use UP and DOWN arrow keys in Set Date menu to set the date Use UP and DOWN arrow keys in Contrast m...

Страница 19: ...the next screen From this menu you can set up and adjust DHW pump activity periods Use the arrow keys to set time HH MM Use Enter button to checkmark desired time period option If no option is check marked the controller will maintain DHW temperature as a priority Only when its preset value is reached the CH circulation pump will start 9 2 3 Burner shut down Standby Pressing the F button will take...

Страница 20: ...he checkmark in the box indicates that the automatic cleaning system is active 9 3 2 Ignition setup In this submenu you can set the number of attempts Retries to ignite the burner and the time of the initial feed portion of pellets Feed Select the desired option using the navigation arrows Use the Enter button to open the next parameter Use the button to open the next page of the menu 9 3 3 Cycle ...

Страница 21: ...y three flames You can modify the pellet quantity Feed time interval at which these pellets are fed Cycle and fan output as a percentage value FAN Example with the period set at 10 seconds the pellet auger runs for 2 seconds feeding pellets in the burner and is off for 8 seconds Select the desired option using the navigation arrows Use the Enter button to open the next parameter Use the button to ...

Страница 22: ...ext parameter Use the button to open the next page of the menu 9 3 7 Suspend Time In this menu you can adjust the time period for which the burner will remain in suspended mode and the time can be set in minutes with a maximum duration of 180 minutes If within a set time 20 minutes the temperature in the boiler does not decrease the burner enters into Extinguishmode crossed out flame 9 3 8 Cleanin...

Страница 23: ...onds and feeds fuel in the burner the internal auger will run for 30 seconds if the setting is Duty 300 see picture Duty parameter can be changed from 0 up to 300 Select the desired option using the navigation arrows Use the Enter button to open the next parameter Use the button to open the next page of the menu This submenu allows you to adjust the conditions under which the p h o t o s e n s o r...

Страница 24: ...ner auger feeder 3 CH Central Heating pump 4 DHW Domestic Hot Water pump 5 Ign Ignition 6 CM Cleaning Motor not available Important This menu is for installers only It is active and visible only if the controller is in Standby 10 SETTING OUTPUT MODES OF OPERATION OF THE PELL PELLET BURNER CAUTION You must use gas analyzer when setting the burner The Pell pellet burner is equipped with three step o...

Страница 25: ...mber of seconds for setting the operation of the main auger for these 10 sec tFEED 300 000 4 8 x 360 x 56 6 hence tFEED 3 sec where 300 000 is the desired output of the burner in Watts W 56 6 is the heating value of the fuel in kWh kg 360 is the number of burning cycles per 1 hour 56 6 is the amount of pellets in grams fed by the auger per 1 second This way the output mode can be changed and inste...

Страница 26: ...l fan setting is tweaked by using gas analyzer to control the oxygen amount registered by the device within the range 8 10 and for the lower modes up to 16 The specific setting depends also on the internal resistance of the boiler combustion chamber on which the burner has been installed as well as on the chimney draught Therefore it is not possible to provide here the exact value for the fan outp...

Страница 27: ...0 sec Fan B E 40 40 1 Suspend Feed 2 sec 2 sec Cycle 60 sec 60 sec Fan B E 20 1 25 Suspend Time 0 min 0 min Interm Cleaning Cycle 30 min 60 sec 30 min 60 sec Fan B E 100 1 100 1 Auto Clean Setup P 06 00 P 10 00 P 14 00 P 18 00 P 22 00 P 02 00 Addons Activacion P CH Pump P DHW Pump P Termostat CH Mode P Thermostat Buffer Hardware Setup P Burner Feeder P Cleaning Motor P Tstat NO Vacuum Feeder P NO ...

Страница 28: ...LLET BURNER Pell Mega 12 1 Elemets of pellet burner Pell Mega Diagram 7 Elemets of pellet burner Pell Mega 1 Pellet burner Pell Mega 5 Control unit 2 Auger flexible pipe connection 6 Burner housing 3 Auger motor 7 Combustion chamber corps 4 Automatic pellet auger 8 Combustion chamber ...

Страница 29: ...ensions Height H Width L Depth D mm 555 1250 420 770 1370 520 Minimal recommended size of boi ler combustion chamber Height Width Depth mm 350 390 550 350 450 550 Required chimney draught Pa 30 30 Heat output adjustment P P Combustion Efficiency Emitted heat 96 93 96 94 Weight of burner kg 90 110 Burner body Length Width Height mm mm 290 550 400 600 Feeder chute Diameter mm 84 84 Built in CPU cont...

Страница 30: ... electronic equipment waste disposal thereof is required separately from the normal flow of solid household waste Obsolete equipment shall be collected separately from other recyclable waste containing materials with adverse effect on health and environment Expired appliances must be collected separately from other recyclable waste containing substances hazardous to health and environment Both met...

Страница 31: ......

Страница 32: ...bg 12 Madara Blvd 9700 Shumen Bulgaria t 359 54 874 555 f 359 54 874 556 e mail ftrade sunsystem bg 13 Chelopeshko Shose Str 1839 Sofia Bulgaria t 359 2 903 97 80 f 359 54 874 556 e mail sales sunsystem bg BG119996Q ...

Отзывы: