Hybrid Parity (Super) Inverter 3.6kW/5.5kW/8.8kW Plus Parallel Version
www.sunsynk.com
``
Use battery SOC for all settings (%).
No battery: tick this box if no battery is connected to the system.
BMS setting.
Active battery - This feature will help recover a battery that is 100% discharged by slowly changing
from the solar array. Until the battery reaches a point where it can change normally.
4.11. Generator and Battery Page
To configure battery charging settings click
on the “Battery” icon and then on “Batt Charge”.
What you can do from this page:
Tick Gen Charge to charge the batteries from the gen I/P.
Tick Grid Charge to charge the batteries from the grid I/P.
Tick Gen Charge signal to auto-switch a relay box.
Tick Grid Charge signal to auto-switch a relay box.
IMPORTANT TO PROTECT YOUR BATTERY AND INVERTER
200Ah AGM battery max. charge/discharge current 40Amps
400Ah AGM battery max. charge/discharge current 80Amps
100Ah AGM battery max. charge/discharge current 75Amps
200Ah AGM battery max. charge/discharge current 100Amps
What you can do from this page:
Generator start voltage/or SOC %.
Grid power start voltage/or SOC %.
Float is for AGM battery 55.20V.
Absorption is for AGM battery 57.60V.
Float V is the voltage at which a battery is
maintained after being fully charged.
Absorption V the level of charge that can be
applied without overheating the battery.
Equalization V 58.80.
Equalizing charge/overcharge to remove
sulfate crystals that build-up on the plates over
time on lead-acid batteries.
IMPORTANT
Do not run this too often since it will damage the battery.