WARNING:

Read all safety warnings and instructions.

 Failure to follow the safety instructions and instructions

can result in electric shock, fire and / or serious injury.
Keep all safety notices and instructions for future use.

Resistance

The maximum temperature of the liquid should not 35 

 in continuous operation.

No flammable, gas-forming or explosive liquids may be conveyed with this pump. This pump
must not be used for other liquids, especially not for engine fuels, cleaning agents and other
chemical products!

Electrical connection

The electrical connection is made to an earthed socket 230 V ~ 50 Hz. Fusing at least 10 A.

The device is switched on and off with the built-in ON/OFF switch (depending on the model).

 

CAUTION:

The devices of the CUP series are UV clarifiers with an integrated pump. They consist of a pump and
a UV lamp. The device must not be used if it is damaged or open, as the UV rays can damage the
eyes and the skin.

This device should be placed under water. Make sure that the device is completely immerged
in the water. The immersion depth should not exceed 2 m.

Do not switch on the device before it is in the water. Damage can occur if the device is oper -
ated without water.

Please ensure that the device is on a solid surface and cannot fall over. Violent vibrations can
damage the quartz glass tube contained therein.

Only use the device if there is no evidence of damage to the cable or to the device itself.

The device must not be operated when there are people or animals in the water.

The maximum pressure that can be exerted on the device is 2 bar.

Areas of application/mode of operation

This UVC device ensures healthy fish and clear water. You can use it in ponds as well as in aquari -
ums. The water is pumped through the UVC device with a pump. There it flows past a UV lamp and is
exposed to UVC radiation, which kills the bacteria, pathogens and floating algae in the water. This will
clarify the water.

Commissioning

Switch on the pump and wait until the device is filled with water. Check all connections for leaks. The
device is put into operation by inserting the mains plug.

© by WilTec Wildanger Technik GmbH 

Item 50341

Page 4 

http://www.WilTec.de
http://www.aoyue.eu

01 2021

-1

http://www.teichtip.de

Содержание CUP-609

Страница 1: ...erating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insigni...

Страница 2: ...nguages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our...

Страница 3: ...indicated on the nameplate of the device must correspond to the ex isting mains voltage Never lift transport or fasten the device by the power cord Make sure that the electrical plug connections are...

Страница 4: ...letely immerged in the water The immersion depth should not exceed 2 m Do not switch on the device before it is in the water Damage can occur if the device is oper ated without water Please ensure tha...

Страница 5: ...len to around 50 after a year 1 Pull out the power plug 2 Switch off the pump and make sure that it cannot be switched on again accidentally 3 Carefully loosen the screw connection at the end of the m...

Страница 6: ...nd in place especially the O ring 12 Finally switch on the power supply to the pump and switch on the device Storage in winter 1 Clean the pump as described above 2 Store the pump out of the water and...

Страница 7: ...nts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the cor...

Отзывы: