Trouble shooting
Problem
Possible cause
Solution
Water pump does not run.
Lack of power
Connect to mains.
Burnt out
Replace water pump.
Rotor clogged
Remove obstruction.
Water pump loud
Rotor clogged
Remove obstruction.
Rotor or shaft worn
Replace rotor or shaft.
Lack of water in water pump
Damaged rotor or closed water
flow valve
Replace rotor or open valve.
Device inlet or water pump inlet
clogged
Remove obstruction.
Voltage too low
Use appropriate voltage.
UVC lamp does not work
Lack of power
Connect to mains.
Damaged UVC lamp
Replace UVC lamp.
Bad connection of UVC lamp
Replace UVC lamp.