Resistance
The temperature of the liquid transported should not 35 ° C in continuous operation.
No flammable, gas-forming or explosive liquids may be conveyed with this pump. This pump must not
be used for other liquids, especially not for engine fuels, cleaning agents and other chemical products!
Electrical connection
•
The electrical connection is made to a 230 V ~ 50 Hz protective contact socket. Fusing at least
10 A.
•
The device is switched on and off with the built-in on/off switch (depending on the model).
Caution:
The CUF series includes UV clarifiers with an integrated pump. The devices consist of a pump and a
UV lamp. The devices must not be operated if they are damaged or open, as the UV rays can damage
the eyes and skin.
•
This device should be placed under water. Make sure that the device is completely sub-
merged in the water. The depth should not exceed 2 m.
•
Do not switch on the device before it is in the water. Damage can occur if the device is oper -
ated without water.
•
Please ensure that the device is on a solid surface and cannot tip over or fall over. Violent vi-
brations can damage the quartz glass tube it contains.
•
Only use the device if there is no evidence of damage to the cable or to the device itself.
•
The device must not be operated when people are in the water.
•
The maximum pressure that can be exerted on the device is 2 bar.
© by WilTec Wildanger Technik GmbH
Item 50945–50947
Page 4
http://www.WilTec.de
http://www.aoyue.eu
12 2020