Attach hoses and hose clamps. 

 

Although the ultraviolet radiation is the lowest of the ionizing radiation, it can be dangerous for 
people  and  other  organisms  as  well.  UV  radiation  with  longer  wavelengths  can  destroy  the 
chemical bonds of the organic molecules, too. Therefore, a responsible approach is necessary 
when dealing with technical UV sources. 

 

Only operate the tubes inside a housing that is closed and not cracked. 

 

 WARNING: 

Read carefully all the safety guidelines and the instructions.

 

Non-compliance with the safety rules and regulations can lead to an electric shock, fire and/or serious 
injury.  Keep  the  instructions  and  the  safety  guidelines  in  a  safe  place  in  case  you  need  them  in  the 
future. 
 
 

Stability

 

 

 

The temperature of the conveyed liquid should not 35 

 in permanent operation. 

 

The conveyance of flammable, gassing or explosive fluids is forbidden. This pump cannot be 
used for other fluids particularly not for motor fuels, cleaning agents or other chemical products. 

 
 
Electrical connection

 

 

The electrical connection takes place via  an electric  safety socket 230 V ~ 50 Hz. Fuse protection at 
least 10 A. 

 

 Warning:

 

 

The UVC filter should be placed in such a way so that the water cannot reach it. The distance 
between the pond edge and the filter should reach at least 2 m. The UV lamp cannot be oper-
ated under water. 

 

The power supply of the UVC filters must not be turned on before the water circulation has been 
carried out. 

 

Please position the UVC filter on a safe and stable place because the pond filter light tube (the 
tube that conveys the light) is made of quartz glass that can burn easily. 

 

Do not turn the power on before all the component parts of the device are installed. 

 

If the quartz glass tube or the upper part of the UVC filter is damaged, the pond pressure filter 
cannot be used. 

 

The UVC filter cannot be used either if there are people in the pond water. 

 

Make sure that the used voltage and the frequency correspond to those indicated on the filter 
label. 

 

When the device is installed, you have to pay attention to the domestic installation rules. 

 

Please do not pull on the connecting cord. Keep it away from heat, grease and sharp objects. 

 

Make sure the upper part of the filter is exposed to pressure lower than 0,3 bar. 

 

In frosty weather please remove the UV filter. 

 

When you install the UV filter, do not expose it to direct sunlight. 

 

Dirt influences the efficiency of the quartz glass tube; therefore, it needs to be regularly cleaned. 

 

To  secure  the  proper  functioning  of  the  device,  the  UV-quartz  tube  should  be  replaced  after 
8000 operating hours. 

 

If the upper part is blocked by sand, the quartz tube can be destroyed. Please place the  filter 
sponge in the inlet of the water pump. 

 

UV light is harmful for the eyes and skin. Do not look directly into the UV light, and do not expose 
your skin to it. 

 

If you install the device or repair it, switch off the power supply of the lamp and the pump. 

 

The device must be installed on a horizontal flat surface with the feet downwards. For safety 
reasons, it not allowed to install the device otherwise. 

 

Содержание 50105

Страница 1: ...nd follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data ca...

Страница 2: ...an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec...

Страница 3: ...to the intended purpose stated in the instructions for use You are responsible for the safety of the working environment If the cable or the plug is damaged due to external influences the cable must n...

Страница 4: ...UVC filters must not be turned on before the water circulation has been carried out Please position the UVC filter on a safe and stable place because the pond filter light tube the tube that conveys t...

Страница 5: ...he device is put into operation Technical data Model Item number Power W Tension V fre quency Suitable for up to Recom mended max flow rate h Input output Fish ponds Decora tive ponds CPF 180 50123 11...

Страница 6: ...PF 10000 CPF 15000 CPF 20000 CPF 30000 Water inlet from the pump into the filter Water flow from the filter into the pond Clean water outlet from the filter to waste water or flower bed The WilTec pre...

Страница 7: ...tlet back to pond should be placed max 2 m over the filter cover 0 2 bar water pres sure The pump must be started first The UVC lamp must not be operated as long as no water flows through it Do not us...

Страница 8: ...o not need Connecting to the water outlet The hose tail with the arrow showing away from filter is the outflow towards the pond Connect a suitable hose to the large diameter step of the hose tail and...

Страница 9: ...tp www WilTec de http www aoyue eu 09 2021 1 http www teichtip de Operating principle of the pressure filter The pressure filter with the integrated UV lamp is a sealed filter system for biological an...

Страница 10: ...filter mainly microorganisms settle that convert ammonium to nitrate In the areas in which the water flows faster yellow filter mainly anaerobic microorganisms accumulate that reduce the nitrate to ni...

Страница 11: ...Use the filter only with hoses that can withstand at least a pressure of 0 2 bar the max pressure of the pump Make sure that outflow discharge in the pond is positioned on a clean place If the outflo...

Страница 12: ...sure the sponges inside the filter are squeezed By using this switch setting the dirty water is not led back into the pump but it is discharged via connection C and it can be used for garden watering...

Страница 13: ...ely designed for filtering pond water with typical impurities Do not expose the filter to the direct sun light over a longer period By frost the filter has to be completely emptied if necessary dug ou...

Страница 14: ...b is placed must be cleaned For this purpose the lime has to be dissolved under heating with appropriate agents coffee machine or kettle descaler like citric acid After this rinse the quartz glass fro...

Страница 15: ...Un ion and other European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal hous...

Отзывы: