SunSun 50105 Скачать руководство пользователя страница 12

 

© by WilTec Wildanger Technik GmbH Item 50105, 50123, 50977

–50980, 50121, 51042–51044 

Page 12 

 

http://www.WilTec.de

 

http://www.aoyue.eu 

  

09 2021

-1

 

http://www.teichtip.de

 

 

Maintenance/cleaning/adjustment possibilities (setting options) (CPF-180/CPF-250 only)

 

 

 

 
 
 
 
 

A

 

B

 

C

 

B1

 

 

D

 

= Pump connection 

= Return to pond (backflow) 

B1  

= Setting 

– filter operation 

C  

= Watering connection 

= Setting 

– cleaning 

E  

= Switch/cleaning mechanism 

 
Filter operation:

 Bring the rotating switch 

E

 into position 

B1.

 With the help of a pump, the water is led 

to the filter through the connection 

A,

 where it is cleaned and discharged back into the pond via con-

nection 

B.

 

 

Cleaning operation: B

ring the switch 

E

 into position 

D.

 This setting enables the cleaning mechanism 

by  pressing  down  the  setting  switch 

E.

  By  means  of  this  pressure,  the  sponges  inside  the  filter  are 

squeezed. By using this switch setting the dirty water is not led back into the pump but it is discharged 
via connection 

C

 and it can be used for garden watering. 

 
The pond filter of the series CPF-2500-5000-10000-15000-20000-30000 have a fast-cleaning function 
that can be  activated with the aid of the crank. Instead of the setting switch (press button) described 
above, turn the crank handle (like the one of a salad spinner) until the filter sponges have lost enough 
dirt. 

 

The filter materials as well as the lamp should be replaced 1× year

 

to ensure a problem-free operation of the filter.

 

 
When the filter is used for normal operation, “the watering connection” 

(C)

 with the screwed ring plus 

sealing and the viewing glass (included in the delivery) should be closed to avoid leaking. The pressure 
filter model of the series CPF-2500-5000-10000-15000-20000-30000 have a stepped hose tail with in-
tegrated ball valve to close the connection. 
 

 

Содержание 50105

Страница 1: ...nd follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data ca...

Страница 2: ...an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec...

Страница 3: ...to the intended purpose stated in the instructions for use You are responsible for the safety of the working environment If the cable or the plug is damaged due to external influences the cable must n...

Страница 4: ...UVC filters must not be turned on before the water circulation has been carried out Please position the UVC filter on a safe and stable place because the pond filter light tube the tube that conveys t...

Страница 5: ...he device is put into operation Technical data Model Item number Power W Tension V fre quency Suitable for up to Recom mended max flow rate h Input output Fish ponds Decora tive ponds CPF 180 50123 11...

Страница 6: ...PF 10000 CPF 15000 CPF 20000 CPF 30000 Water inlet from the pump into the filter Water flow from the filter into the pond Clean water outlet from the filter to waste water or flower bed The WilTec pre...

Страница 7: ...tlet back to pond should be placed max 2 m over the filter cover 0 2 bar water pres sure The pump must be started first The UVC lamp must not be operated as long as no water flows through it Do not us...

Страница 8: ...o not need Connecting to the water outlet The hose tail with the arrow showing away from filter is the outflow towards the pond Connect a suitable hose to the large diameter step of the hose tail and...

Страница 9: ...tp www WilTec de http www aoyue eu 09 2021 1 http www teichtip de Operating principle of the pressure filter The pressure filter with the integrated UV lamp is a sealed filter system for biological an...

Страница 10: ...filter mainly microorganisms settle that convert ammonium to nitrate In the areas in which the water flows faster yellow filter mainly anaerobic microorganisms accumulate that reduce the nitrate to ni...

Страница 11: ...Use the filter only with hoses that can withstand at least a pressure of 0 2 bar the max pressure of the pump Make sure that outflow discharge in the pond is positioned on a clean place If the outflo...

Страница 12: ...sure the sponges inside the filter are squeezed By using this switch setting the dirty water is not led back into the pump but it is discharged via connection C and it can be used for garden watering...

Страница 13: ...ely designed for filtering pond water with typical impurities Do not expose the filter to the direct sun light over a longer period By frost the filter has to be completely emptied if necessary dug ou...

Страница 14: ...b is placed must be cleaned For this purpose the lime has to be dissolved under heating with appropriate agents coffee machine or kettle descaler like citric acid After this rinse the quartz glass fro...

Страница 15: ...Un ion and other European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal hous...

Отзывы: