INSTALLATION AND ASSEMBLY

 

- Island Safety 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ATTENTION:

 

Upper and lower air vents (20 sq. in. minimum each) MUST BE PROVIDED on both sides 

of built-in construction. The height from upper air vent to top surface of island is 5", and the height from 
lower air vent to the bottom is 5”.

 

Island units must have vents cut into the island sides regardless of whether the grill is kept as NG or is 
converted to LP. If no vent openings are made in the island unit, the grill will overheat and cause a fire 
hazard! If you have an L.P. model with a 20lb cylinder stored in the enclosure, ensure that there at least two 
air ventilation openings of 20sq inches 180 degrees apart and they are level with the cylinder valve. Another 
two openings with the same dimensions and distance are required to be level with the base of the cylinder. 
 

 

Do not use an extension cord to supply power to your island, or appliance. Such use may result in a 
fire, Electrical shock or other personal injury. 

 

Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result 
in an Electrical shock hazard. 

 

Use only Ground Fault Interrupter (GFI) protected circuit with this outdoor kitchen island. 

 

Keep all electrical components covered and secured away from any water or other liquids. 

 

Use only extension cords with a 3 prong grounding plug, rated for power of equipment, and approved 
for outdoor use with a W-A marking. 

 

 

Page 

3

 

Содержание SUN4B

Страница 1: ...elp and position grill near your island where the grill is being installed 2 Remove the green straps from around the grill box carton 3 Lift the cardboard box up and off be sure to tilt it back then t...

Страница 2: ...on may result For Built in Installations Outdoor Kitchen Island should be built with NON Combustible applications including masonry stone or brick Never build deck below grill grill is supported by co...

Страница 3: ...tion openings of 20sq inches 180 degrees apart and they are level with the cylinder valve Another two openings with the same dimensions and distance are required to be level with the base of the cylin...

Страница 4: ...side of grill See figure A Correct Way and figure B Wrong Way Page 9 CAUTION Any damage resulting from windy conditions causing overheating including melted knobs or igniter wires and impulse igniter...

Страница 5: ...Sunstone grill is specially designed with an internal built in hanger lip located at the Right Left and Back sides The grill lip allows it to hang by the three supported edges on the right left and ba...

Страница 6: ...W See Diagram Page 11 to Right From Back Cut Out Grill Line to Wall 8 Min Clearance From Counter to Outdoor Vent Hood 36 Min Clearance From Floor to Counter Top 38 Min Clearance From Grill to Vent Hoo...

Страница 7: ...INSTALLATION AND ASSEMBLY Locating Grill Page 7...

Страница 8: ...sible Items located near your cleanup zone will include not only items you ll use to clean up your outdoor kitchen and dishes below access storage and trash drawer for easy clean up BEVERAGE ZONE The...

Отзывы: