INSTALLATION AND ASSEMBLY
- Island Safety
ATTENTION:
Upper and lower air vents (20 sq. in. minimum each) MUST BE PROVIDED on both sides
of built-in construction. The height from upper air vent to top surface of island is 5", and the height from
lower air vent to the bottom is 5”.
Island units must have vents cut into the island sides regardless of whether the grill is kept as NG or is
converted to LP. If no vent openings are made in the island unit, the grill will overheat and cause a fire
hazard! If you have an L.P. model with a 20lb cylinder stored in the enclosure, ensure that there at least two
air ventilation openings of 20sq inches 180 degrees apart and they are level with the cylinder valve. Another
two openings with the same dimensions and distance are required to be level with the base of the cylinder.
Do not use an extension cord to supply power to your island, or appliance. Such use may result in a
fire, Electrical shock or other personal injury.
Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result
in an Electrical shock hazard.
Use only Ground Fault Interrupter (GFI) protected circuit with this outdoor kitchen island.
Keep all electrical components covered and secured away from any water or other liquids.
Use only extension cords with a 3 prong grounding plug, rated for power of equipment, and approved
for outdoor use with a W-A marking.