GAS SETUP – INSTALLATION OVERVIEW

 

PAGE 10 

           

CAUTION:

 

Gas conversion kits are available from Customer care by dialing 888-934-9449. 

When ordering gas conversion kits, have the model number, and the type of gas (natural or LP) ready. 

 

Use only the gas pressure regulator supplied with this appliance. This 

regulator is set for an outlet pressure of 11 inches water column.  

 

An installer-supplied gas shut-off valve must be installed in an easily 

accessible location. 

 

All pipe sealants must be an approved type and resistant to the 

actions of LP/NG Gas.  

 

Never use pipe sealant on flare fittings.  

 

All gas connections should be made by a qualified technician and in 

accordance with local codes and ordinances. 

 

Before connecting grill to gas source, make sure BBQ Grill control 

knobs are in “OFF” position.  

 

Verify the type of gas supply to be used, either Natural Gas or Liquid 

Propane, and make sure the marking on the appliance rating label 

agrees with that of the supply. 

 

The installation of this appliance must conform with local codes or, in the 

absence of local codes, with either National Fuel Gas Code, ANSI Z223.1/ NFPA 

54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage 

and Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI A 

119.2/ NFPA 1192M, and CSA Z240 RV Series, Recreational Vehicle Code, as 

applicable. 

                

ATTENTION:

 

Always take a leak test before lighting the grill to prevent a possible fire or explosion. 

Never store a spare propane

 

cylinder in the vicinity of this Grill, or in the vicinity of any other potential heat 

source. Never attempt to attach this grill

 

to the self-contained LP gas system. Do not use grill until leak 

testing.

 

Содержание Ruby Companion Pro

Страница 1: ...you operate your grill Save these instructions To installer or person assembling grill Leave this manual with grill for future reference To consumer Keep this manual for future reference www sunstone...

Страница 2: ...k Please make sure you have the following information MODEL NUMBER DATE OF PURCHASE INVOICE NUMBER For warranty service contact SUNSTONE Customer Service Department at 888 934 9449 or email service su...

Страница 3: ...SION Indicates an imminently hazardous situation which if not avoided will result in possible explosion and cause death or severe injury BODILY INJURY Indicates a potentially hazardous situation which...

Страница 4: ...e maintained All packaging has been removed from Interior of Grill All parts and components are properly installed An installer supplied manual gas shut off valve is fully accessible LP hose is clean...

Страница 5: ...SUN13CPRO MANI 16 Piezo Valve LP NG 2 SUN13CPRO VALVE LP NG 17 Fire Box 1 SUN13CPRO FBOX 18 Knob Ring 2 P KNOB RING 19 Knob Control Panel 1 SUN13CPRO KCPANEL 20 Thermo Coupler 2 SUN13CPRO THERMO 21 Oi...

Страница 6: ...GRILL PARTS PARTS DIAGRAM PAGE 2...

Страница 7: ...Elect Connection Locate the Light Button on Left side of grill control panel The Transformer s electrical connection to grill is located behind control panel next to light button The connection clips...

Страница 8: ...ll the way into cut out there is a stopper flange just behind the back vent which will insure the area stays clear for adequate air flow to the bottom burners The Control Panel should be flush against...

Страница 9: ...3 4 Box Depth includes flange 22 1 2 GRILL INSTALLATION PRODUCT DETAILS PAGE 5 Technical Measurements If you are installing grill into cabinet structure you may need to refer to these engineer dimens...

Страница 10: ...allation A Grill Cut out Depth 22 Depth B Grill Cut out Height Allow Air Flow Gap Below Drip Pan 10 1 2 Height C Grill Cut out Width 11 Width D Make 1 x1 D Notch Cut Out on both side of cut out counte...

Страница 11: ...ior outside wall or roof and there is a Minimum of Two adjacent sides which are open with outside exposure PAGE 7 ATTENTION All Gas Grill Installations MUST HAVE MINIMUM TWO AIR FLOW VENTS either in E...

Страница 12: ...lor or damage unprotected areas do not install under unprotected combustible construction without using a fire safe ventilation system A 24 minimum clearance must be maintained under the countertop to...

Страница 13: ...our Warranty may be VOID if island does not meet basic setup requirements GRILL INSTALLATION ENCLOSED INSTALLATION PAGE 9 Enclosed Installation Definition Structure built above Appliance that is attac...

Страница 14: ...ake sure BBQ Grill control knobs are in OFF position Verify the type of gas supply to be used either Natural Gas or Liquid Propane and make sure the marking on the appliance rating label agrees with t...

Страница 15: ...me with an independent LP regulator for this type of installation Contact the company you purchased from or your local plumber to locate one that is made for commercial style grills Large Capacity LP...

Страница 16: ...mit the flow of gas to 10 cubic feet per hour NEVER use grill without leak testing GAS SETUP MEDIUM CAPACITY LP TANKS PAGE 12 Follow Instructions 1 The tank valve all Knobs should be in the OFF positi...

Страница 17: ...ATURAL GAS INSTALLATION PAGE 13 Follow Instructions 1 The tank valve all Knobs should be in the OFF position If not turn the knob clockwise until it stops 2 Insert the regulator inlet into the tank va...

Страница 18: ...gh the cooking grids If the burner does not light on the first try repeat immediately 5 If the burner does not light in 5 seconds then wait five minutes until the gas clears before attempting to light...

Страница 19: ...e LED light strip you will now have access to You can then easily unplug and replace LED light with new one or check for other loose connections Q The Gas Burners flame is very Low A If your grill is...

Страница 20: ...contingent damages resulting from its breach of this written warranty or any implied warranty 6 Some states do not allow limitations on how long an implied warranty lasts or the exclusions of or limit...

Отзывы: