43
■
Error List
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Not read!
scale err!
needle POS!
limit err!
clamp err!
X org err!
ROM err!
count:0
pin hole!
ROM err!
Format!
SMPS err!
motor type
Y org err!
E_switch
Com LRC
over voltage!
low voltage!
Start err
No Patt!
Pause Key!
belt!
OP-eepr24LC08
OP-eepr28C010
Air low!
Power off!
OP cable
ORG err!
sensor1
sensor2
sensor3
sensor4
sensor5
○
○
×
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
×
○
○
○
○
○
○
○
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine in general
Sewing machine motor
Sewing machine motor
Sewing machine in general
OP Box
OP Box
Sewing machine in general
Supply device
Supply device
Supply device
Supply device
Supply device
Sewing machine in general
Supply device
Supply device
Supply device
Supply device
Supply device
ERR1
ERR2
ERR3
ERR4
ERR5
ERR6
ERR8
ERR10
ERR11
ERR12
ERR13
ERR14
ERR15
ERR16
ERR17
ERR18
ERR19
ERR20
ERR21
ERR22
ERR23
ERR30
ERR31
ERR32
ERR33
ERR34
ERR35
ERR36
ERR41
ERR42
ERR43
ERR44
ERR45
Error Message
Description
Alarm
Pin No.
Pattern cannot be called
Zoom-in/out error
Needle bar position error
Feed limit error
Clamp position error
Failure to move to X-origin within given time
ROM version error, not compatible with new digital
version
Counter is set at “0”
Pin hole does not move up or down.
Extended ROM is not mounted or faulty.
Formatting is not completed.
SMPS fan operation is faulty.
Failure in sensing the main motor type
Failure to return to Y-origin within given time
Emergency switch is pressed.
Sewing data transmission error (during pattern creation)
Excessive voltage
Low voltage
The supply device's advance time to sewing machine
exceeds the set time.
Range value was not entered for pattern generation.
Pause key is pressed
Sensor setting error in case of thick sewing material
OP’s 24LC08 error
OP’s AT28C010 error
Air pressure below required level
Input voltage is unstable or power is turned off
Pneumatic cable is not attached.
Origin cable is separated or XY origin sensor is faulty.
Supply device's initial position sensor check (S1).
Clamp rear sensor check (S8)
Clamp front sensor check (S6)
Supply device's middle sensor check (S2)
Cutter device lower sensor check (S4)