![SunStar SJS/A-BA2 Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/sunstar/sjs-a-ba2/sjs-a-ba2_user-manual_1400331038.webp)
39
4.9) Function
Function is used to change parameter values.
4.9.1) Function
※
AIR should be "ON."
①
When (ENTER) is pressed, it moves forward. When
(ENTER) is pressed again, it moves backward.
②
Whenever (ENTER) is pressed, feeding time appears.
③
Press the UP/DOWN key to select items from No. 1 to
No. 4.
4.8.5) Setting function
The test item setting enables the measuring of the time taken for forward and backward movement of the feeding and
clamp parts.
[set] on the left is a default value and [time] on the right is the current time. If the difference between [set] and [time] is
significant, the speed can be adjusted with the pneumatic valve.
↓
①
While the power is off, press the (No) key and the
(Speed) key at the same time and turn on the power.
②
Use the UP/DOWN keys to select an item and press the
(ENTER) key. The value is automatically filled. When
the (ESC) key is pressed, the value is not automatically
filled.
↓
(When the Enter or ESC key is pressed, the screen
below appears.)
③
Turn off the power.
/
■
Setting Details
No
Operation 1
Operation 2
1
Forward time of supplier
Backward time of supplier
2
Forward time of clamp
Short backward and return time of clamp
3
Short forward time
Return time
4
Ready motion time
1Cycle motion time