5) Location Detector Assembly and
Adjustment
(1) Installing the location detector
A. Installing on the servo motor (in-built location detector)
A location detector sensor is attached to the back side of
the arm. The appropriate clearance between the location
detector and the pulley is 0.5mm. (See Fig. 7)
After assembling the parts in the numbered order as in Fig. 8, adjust the synchronization shaft horizontally such that the
photo film is placed at the center of the photo interrupter as in Fig. 9. Then fasten it tightly with two fixing screws using a
hexagonal wrench.
[Caution]
Assemble after adjusting the position such that the letters
“
UP
”
and
“
DOWN
”
are facing the front side when
seen from the pulley as is shown in Fig. 8.
The film will already be adjusted by default.
(2) Installing the 470 motor
6) Location Adjustment of Location Detector
(1) For in-built location detectors
Adjust the up-stop position of the needle such that the white carved sign on the pulley
③
is in a straight line with the
carved sign on the arm
④
when the needle has stopped in the air. That adjustment can be made by loosening the pulley
’
s
clamp screw
①
on the side with N?U carved signs and moving it sideways. Adjust the down-stop position of the needle
such that the needle is on the point of moving up when the needle bar is at the lowest point. This adjustment can be made
by loosening the pulley
’
s clamp screw
②
on the side with N
·
D carved signs and moving it sideways. (See Fig. 10 & 11)
Speed Sensor Film
Fixed Washer
Fixed Bushing
Fixed Screws
Pulley
L Wrench
PCB Holder
COVER
Photo
Interrupter
Photo Film
Synchronization Shaft
Synchronization Shaft Fixed
Screws (2)
Location
Detector
Shaft
Fixed
Washer
Clearance-Adjusting Bushing
[Fig.7]
[Fig.8] [Fig.9]
[Fig.10] [Fig.11]
Содержание SC-7007S
Страница 1: ...USER S MANUAL SC 700 SERIES R ...